Fix physical disks vanishing on wide nodes and standby-misreporting SSDs

rcourtmanf2b732721e66
diff --git a/internal/api/setup_script_render.go b/internal/api/setup_script_render.go
index 762a0799b4..7dd08771c4 100644
--- a/internal/api/setup_script_render.go
+++ b/internal/api/setup_script_render.go
@@ -935,6 +935,19 @@ def canonical_block_for_device(device):
return name
+def is_non_rotational_block_device(device):
+ # Positively confirmed SSD via sysfs; anything uncertain returns False so
+ # the caller keeps the conservative standby guard.
+ block = canonical_block_for_device(device)
+ if not block:
+ return False
+ try:
+ with open("/sys/block/%%s/queue/rotational" %% block) as handle:
+ return handle.read().strip() == "0"
+ except Exception:
+ return False
+
+
def inferred_smart_device_types(device):
name = os.path.basename(str(device or "").strip()).lower()
if re.fullmatch(r"(sd|hd)[a-z]+", name or ""):
@@ -1184,7 +1197,15 @@ def collect_smart():
args = [path]
if attempt_type:
args.extend(["-d", attempt_type])
- args.extend(["-n", "standby,3", "-i", "-A", "-H", "--json=o", attempt_device])
+ # The standby guard avoids spinning up sleeping rotational disks.
+ # SSDs have nothing to spin up, and some SATA SSDs answer CHECK
+ # POWER MODE with a bogus standby state that permanently hides
+ # their SMART data (#1516), so confirmed SSDs are probed without
+ # it. Multiplexed members keep the guard: the shared /dev path's
+ # rotational flag describes the array, not the member.
+ if is_multiplexed_device_type(attempt_type) or not is_non_rotational_block_device(attempt_device):
+ args.extend(["-n", "standby,3"])
+ args.extend(["-i", "-A", "-H", "--json=o", attempt_device])
result = run_command(args)
if not result or not result.stdout.strip():
diff --git a/internal/hostagent/smartctl.go b/internal/hostagent/smartctl.go
index dcb627688a..09d3b9fd32 100644
--- a/internal/hostagent/smartctl.go
+++ b/internal/hostagent/smartctl.go
@@ -1213,10 +1213,34 @@ func smartctlArgs(device, deviceType string) []string {
if deviceType != "" {
args = append(args, "-d", deviceType)
}
- args = append(args, "-n", "standby,"+strconv.Itoa(smartctlStandbyExitStatus), "-i", "-A", "-H", "--json=o", device)
+ // The standby guard exists to avoid spinning up sleeping rotational disks.
+ // An SSD has nothing to spin up, and some SATA SSDs answer the guard's
+ // CHECK POWER MODE with a bogus standby state that permanently hides their
+ // SMART data (#1516), so confirmed non-rotational devices are probed
+ // without it. Multiplexed controller members keep the guard: the shared
+ // /dev path's rotational flag describes the array device, not the member.
+ if isMultiplexedDeviceType(deviceType) || !linuxNonRotationalBlockDevice(device) {
+ args = append(args, "-n", "standby,"+strconv.Itoa(smartctlStandbyExitStatus))
+ }
+ args = append(args, "-i", "-A", "-H", "--json=o", device)
return args
}
+// linuxNonRotationalBlockDevice reports whether the canonical block device
+// behind path is positively confirmed non-rotational (SSD) via sysfs. Any
+// uncertainty — non-Linux, unresolvable device, unreadable sysfs — returns
+// false so the caller keeps the conservative standby guard.
+func linuxNonRotationalBlockDevice(device string) bool {
+ if runtimeGOOS != "linux" {
+ return false
+ }
+ block := canonicalBlockDeviceForScanPath(device)
+ if block == "" {
+ return false
+ }
+ return readTrimmedFile(filepath.Join("/sys/block", block, "queue", "rotational")) == "0"
+}
+
func smartctlArgsWithLog(args []string, logPage string) []string {
if logPage == "" || len(args) == 0 {
return append([]string(nil), args...)
diff --git a/internal/hostagent/smartctl_standby_guard_test.go b/internal/hostagent/smartctl_standby_guard_test.go
new file mode 100644
index 0000000000..09bfd4e6e1
--- /dev/null
+++ b/internal/hostagent/smartctl_standby_guard_test.go
@@ -0,0 +1,110 @@
+package hostagent
+
+import (
+ "fmt"
+ "io/fs"
+ "strings"
+ "testing"
+)
+
+// The -n standby guard exists to avoid spinning up sleeping rotational disks.
+// SSDs have nothing to spin up, and some SATA SSDs answer CHECK POWER MODE
+// with a bogus standby state that permanently hides their SMART data (#1516),
+// so confirmed non-rotational devices must be probed without the guard.
+func TestSmartctlArgsStandbyGuard(t *testing.T) {
+ origGOOS := runtimeGOOS
+ origReadFile := smartctlReadFile
+ t.Cleanup(func() {
+ runtimeGOOS = origGOOS
+ smartctlReadFile = origReadFile
+ })
+
+ rotationalByDevice := map[string]string{}
+ smartctlReadFile = func(path string) ([]byte, error) {
+ for device, value := range rotationalByDevice {
+ if path == fmt.Sprintf("/sys/block/%s/queue/rotational", device) {
+ return []byte(value + "\n"), nil
+ }
+ }
+ return nil, fs.ErrNotExist
+ }
+
+ hasStandbyGuard := func(args []string) bool {
+ for i, arg := range args {
+ if arg == "-n" && i+1 < len(args) && strings.HasPrefix(args[i+1], "standby,") {
+ return true
+ }
+ }
+ return false
+ }
+
+ tests := []struct {
+ name string
+ goos string
+ device string
+ deviceType string
+ rotational map[string]string
+ wantGuard bool
+ }{
+ {
+ name: "linux ssd drops guard",
+ goos: "linux",
+ device: "/dev/sda",
+ deviceType: "sat",
+ rotational: map[string]string{"sda": "0"},
+ wantGuard: false,
+ },
+ {
+ name: "linux hdd keeps guard",
+ goos: "linux",
+ device: "/dev/sdb",
+ deviceType: "sat",
+ rotational: map[string]string{"sdb": "1"},
+ wantGuard: true,
+ },
+ {
+ name: "unreadable sysfs keeps guard",
+ goos: "linux",
+ device: "/dev/sdc",
+ deviceType: "",
+ rotational: map[string]string{},
+ wantGuard: true,
+ },
+ {
+ name: "multiplexed member keeps guard even when array is non-rotational",
+ goos: "linux",
+ device: "/dev/sda",
+ deviceType: "megaraid,7",
+ rotational: map[string]string{"sda": "0"},
+ wantGuard: true,
+ },
+ {
+ name: "non-linux keeps guard",
+ goos: "freebsd",
+ device: "/dev/ada0",
+ deviceType: "sat",
+ rotational: map[string]string{"ada0": "0"},
+ wantGuard: true,
+ },
+ }
+
+ for _, tc := range tests {
+ t.Run(tc.name, func(t *testing.T) {
+ runtimeGOOS = tc.goos
+ rotationalByDevice = tc.rotational
+
+ args := smartctlArgs(tc.device, tc.deviceType)
+ if got := hasStandbyGuard(args); got != tc.wantGuard {
+ t.Fatalf("smartctlArgs(%q, %q) standby guard = %v, want %v (args %v)",
+ tc.device, tc.deviceType, got, tc.wantGuard, args)
+ }
+ // The probe flags and device must survive in both shapes.
+ joined := strings.Join(args, " ")
+ for _, required := range []string{"-i", "-A", "-H", "--json=o", tc.device} {
+ if !strings.Contains(joined, required) {
+ t.Fatalf("smartctlArgs(%q, %q) missing %q in %v", tc.device, tc.deviceType, required, args)
+ }
+ }
+ })
+ }
+}
diff --git a/internal/monitoring/monitor_pve.go b/internal/monitoring/monitor_pve.go
index 310ea26387..b72c722596 100644
--- a/internal/monitoring/monitor_pve.go
+++ b/internal/monitoring/monitor_pve.go
@@ -870,8 +870,14 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
go func(inst string, pveClient PVEClientInterface, nodeList []proxmox.Node, nodeStatus map[string]string, modelNodesCopy []models.Node) {
defer recoverFromPanic(fmt.Sprintf("pollPhysicalDisks-%s", inst))
- // Use a generous timeout for disk polling
+ // Use a generous timeout for disk polling. Each node gets its own
+ // attempt window below, so the overall budget scales to the polling
+ // interval: one slow node must not consume the whole instance budget,
+ // and staying inside the interval means polls can never overlap.
diskTimeout := 60 * time.Second
+ if pollingInterval > diskTimeout {
+ diskTimeout = pollingInterval
+ }
// Use monitor lifecycle context so shutdown can interrupt detached async polling.
parentCtx := m.getRuntimeContext()
if parentCtx == nil {
@@ -907,12 +913,21 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
for _, h := range hosts {
hostByID[h.ID] = h
}
+ // Also map node name → linked host agent SMART inventory so a node whose
+ // Proxmox disk query fails can still populate its physical disks from
+ // the agent's smartctl view (#1516).
+ smartByNode := make(map[string][]models.HostDiskSMART)
for _, n := range nodesFromState {
if n.LinkedAgentID == "" || n.Instance != inst {
continue
}
- if linkedHost, ok := hostByID[n.LinkedAgentID]; ok && len(linkedHost.DiskExclude) > 0 {
- diskExcludeByNode[n.Name] = linkedHost.DiskExclude
+ if linkedHost, ok := hostByID[n.LinkedAgentID]; ok {
+ if len(linkedHost.DiskExclude) > 0 {
+ diskExcludeByNode[n.Name] = linkedHost.DiskExclude
+ }
+ if len(linkedHost.Sensors.SMART) > 0 {
+ smartByNode[n.Name] = linkedHost.Sensors.SMART
+ }
}
}
@@ -920,14 +935,16 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
polledNodes := make(map[string]bool) // Track which nodes we successfully polled
zfsPoolingEnabled := zfsMonitoringEnabledFromEnv()
+ nodeLoop:
for _, node := range nodeList {
- // Check if context timed out
+ // Check if context timed out. Break instead of returning so the
+ // nodes already polled still land in state.
select {
case <-diskCtx.Done():
log.Debug().
Str("instance", inst).
- Msg("Physical disk polling timed out - preserving existing data")
- return
+ Msg("Physical disk polling timed out - saving partial results")
+ break nodeLoop
default:
}
@@ -937,9 +954,13 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
continue
}
+ // Each node gets its own attempt window so one slow node cannot
+ // starve the rest of the cluster's disk poll.
+ nodeCtx, nodeCancel := context.WithTimeout(diskCtx, 60*time.Second)
+
// Get disk list for this node
log.Debug().Str("node", node.Node).Msg("getting disk list for node")
- disks, err := pveClient.GetDisks(diskCtx, node.Node)
+ disks, err := pveClient.GetDisks(nodeCtx, node.Node)
if err != nil {
// Check if it's a permission error or if the endpoint doesn't exist
errStr := err.Error()
@@ -958,6 +979,20 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
Err(err).
Msg("Failed to get disk list")
}
+ // The Proxmox query failed, but a linked host agent sees the
+ // same disks via smartctl. Wide nodes (dozens of disks) can
+ // exceed the API window PVE itself allows for disks/list, so
+ // without this fallback their Physical Disks view empties
+ // permanently (#1516).
+ if fallback := physicalDisksFromHostAgentSMART(inst, node.Node, smartByNode[node.Node]); len(fallback) > 0 {
+ polledNodes[node.Node] = true
+ allDisks = append(allDisks, fallback...)
+ log.Info().
+ Str("node", node.Node).
+ Int("diskCount", len(fallback)).
+ Msg("Proxmox disk query failed - using linked host agent SMART inventory for physical disks")
+ }
+ nodeCancel()
continue
}
@@ -969,7 +1004,7 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
// non-fatal; we simply leave StorageGroup empty.
var poolAssignment *diskPoolAssignment
if zfsPoolingEnabled {
- if pools, pErr := pveClient.GetZFSPoolsWithDetails(diskCtx, node.Node); pErr == nil {
+ if pools, pErr := pveClient.GetZFSPoolsWithDetails(nodeCtx, node.Node); pErr == nil {
poolAssignment = buildDiskPoolAssignment(pools)
} else {
log.Debug().
@@ -978,6 +1013,7 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
Msg("Could not fetch ZFS pool details for disk→pool mapping; StorageGroup will be empty")
}
}
+ nodeCancel()
// Record each disk; alert evaluation happens after host-agent SMART merges
// so the canonical disk view includes post-merge health/wearout data.
@@ -1064,6 +1100,52 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
}(instanceName, client, nodes, nodeEffectiveStatus, modelNodes)
}
+// physicalDisksFromHostAgentSMART builds PhysicalDisk entries for a node from
+// its linked host agent's SMART inventory. This is the fallback when the
+// Proxmox disks/list query fails: PVE probes SMART per disk inside that call,
+// so a node with dozens of disks can exceed the API window and the view would
+// otherwise empty even though the agent on the node sees every disk (#1516).
+// Only what the agent actually reports is carried over; nothing is fabricated.
+func physicalDisksFromHostAgentSMART(inst, nodeName string, smartEntries []models.HostDiskSMART) []models.PhysicalDisk {
+ if len(smartEntries) == 0 {
+ return nil
+ }
+ now := time.Now()
+ disks := make([]models.PhysicalDisk, 0, len(smartEntries))
+ for _, smart := range smartEntries {
+ device := strings.TrimSpace(smart.Device)
+ if device == "" {
+ continue
+ }
+ devPath := device
+ if !strings.HasPrefix(devPath, "/dev/") {
+ devPath = "/dev/" + devPath
+ }
+ health := strings.TrimSpace(smart.Health)
+ if health == "" {
+ health = "UNKNOWN"
+ }
+ disks = append(disks, models.PhysicalDisk{
+ ID: fmt.Sprintf("%s-%s-%s", inst, nodeName, strings.ReplaceAll(devPath, "/", "-")),
+ Node: nodeName,
+ Instance: inst,
+ DevPath: devPath,
+ Model: strings.TrimSpace(smart.Model),
+ Serial: strings.TrimSpace(smart.Serial),
+ WWN: strings.TrimSpace(smart.WWN),
+ Type: strings.TrimSpace(smart.Type),
+ Size: smart.SizeBytes,
+ Health: health,
+ Wearout: deriveWearoutFromSMARTAttributes(smart.Attributes),
+ Temperature: smart.Temperature,
+ StorageGroup: strings.TrimSpace(smart.Pool),
+ SmartAttributes: smartAttributesCopy(smart.Attributes),
+ LastChecked: now,
+ })
+ }
+ return disks
+}
+
func proxmoxDiskFromPhysicalDisk(disk models.PhysicalDisk) proxmox.Disk {
return proxmox.Disk{
DevPath: disk.DevPath,
diff --git a/internal/monitoring/monitor_pve_disk_fallback_test.go b/internal/monitoring/monitor_pve_disk_fallback_test.go
new file mode 100644
index 0000000000..ddf47ea013
--- /dev/null
+++ b/internal/monitoring/monitor_pve_disk_fallback_test.go
@@ -0,0 +1,148 @@
+package monitoring
+
+import (
+ "context"
+ "fmt"
+ "testing"
+ "time"
+
+ "github.com/rcourtman/pulse-go-rewrite/internal/alerts"
+ "github.com/rcourtman/pulse-go-rewrite/internal/config"
+ "github.com/rcourtman/pulse-go-rewrite/internal/models"
+ "github.com/rcourtman/pulse-go-rewrite/pkg/proxmox"
+)
+
+func int64PtrDiskFallback(v int64) *int64 { return &v }
+
+func TestPhysicalDisksFromHostAgentSMART_BuildsDisks(t *testing.T) {
+ entries := []models.HostDiskSMART{
+ {
+ Device: "sda",
+ Model: "ST18000NM019J",
+ Serial: "ZR5DLAYJ",
+ WWN: "5-c500-da60ca43",
+ Type: "sas",
+ SizeBytes: 18000207937536,
+ Temperature: 30,
+ Health: "PASSED",
+ Pool: "tank",
+ Attributes: &models.SMARTAttributes{PowerOnHours: int64PtrDiskFallback(327)},
+ },
+ {
+ // Standby entry keeps its identity but carries no health reading.
+ Device: "sdb",
+ Model: "ST18000NM019J",
+ Serial: "ZR5DLXYZ",
+ Type: "sas",
+ Standby: true,
+ },
+ {
+ // Entries without a device name cannot form a stable ID.
+ Device: " ",
+ },
+ }
+
+ disks := physicalDisksFromHostAgentSMART("pve1", "node1", entries)
+ if len(disks) != 2 {
+ t.Fatalf("expected 2 disks, got %d: %+v", len(disks), disks)
+ }
+
+ first := disks[0]
+ if first.ID != "pve1-node1--dev-sda" {
+ t.Errorf("unexpected ID %q", first.ID)
+ }
+ if first.DevPath != "/dev/sda" || first.Node != "node1" || first.Instance != "pve1" {
+ t.Errorf("unexpected identity fields: %+v", first)
+ }
+ if first.Health != "PASSED" || first.Temperature != 30 || first.Size != 18000207937536 {
+ t.Errorf("unexpected data fields: %+v", first)
+ }
+ if first.StorageGroup != "tank" {
+ t.Errorf("expected pool carried into StorageGroup, got %q", first.StorageGroup)
+ }
+ if first.SmartAttributes == nil || first.SmartAttributes.PowerOnHours == nil || *first.SmartAttributes.PowerOnHours != 327 {
+ t.Errorf("expected SMART attributes carried over, got %+v", first.SmartAttributes)
+ }
+ if first.Wearout != -1 {
+ t.Errorf("expected wearout unknown (-1) without wear attributes, got %d", first.Wearout)
+ }
+
+ second := disks[1]
+ if second.DevPath != "/dev/sdb" || second.Health != "UNKNOWN" {
+ t.Errorf("expected standby disk listed with UNKNOWN health, got %+v", second)
+ }
+
+ if got := physicalDisksFromHostAgentSMART("pve1", "node1", nil); got != nil {
+ t.Errorf("expected nil for empty SMART inventory, got %+v", got)
+ }
+}
+
+type disksErrorPVEClient struct {
+ fakeStorageClient
+}
+
+func (*disksErrorPVEClient) GetDisks(ctx context.Context, node string) ([]proxmox.Disk, error) {
+ return nil, fmt.Errorf("596 connection timed out")
+}
+
+// A node whose Proxmox disks/list query fails (wide nodes can exceed the API
+// window) must still populate its Physical Disks view from the linked host
+// agent's SMART inventory instead of silently emptying (#1516).
+func TestMaybePollPhysicalDisksAsync_AgentFallbackWhenDiskQueryFails(t *testing.T) {
+ m := &Monitor{
+ state: models.NewState(),
+ lastPhysicalDiskPoll: make(map[string]time.Time),
+ alertManager: alerts.NewManager(),
+ }
+
+ m.state.UpdateNodesForInstance("pve1", []models.Node{{
+ ID: "pve1-node1",
+ Name: "node1",
+ Instance: "pve1",
+ LinkedAgentID: "host-1",
+ }})
+ m.state.UpsertHost(models.Host{
+ ID: "host-1",
+ Hostname: "node1",
+ Sensors: models.HostSensorSummary{
+ SMART: []models.HostDiskSMART{{
+ Device: "sda",
+ Model: "ST18000NM019J",
+ Serial: "ZR5DLAYJ",
+ Type: "sas",
+ SizeBytes: 18000207937536,
+ Temperature: 30,
+ Health: "PASSED",
+ }},
+ },
+ })
+
+ m.maybePollPhysicalDisksAsync(
+ context.Background(),
+ "pve1",
+ &config.PVEInstance{},
+ &disksErrorPVEClient{},
+ []proxmox.Node{{Node: "node1", Status: "online"}},
+ map[string]string{"node1": "online"},
+ []models.Node{{Name: "node1"}},
+ )
+
+ deadline := time.Now().Add(3 * time.Second)
+ for {
+ disks := m.state.GetSnapshot().PhysicalDisks
+ if len(disks) == 1 {
+ disk := disks[0]
+ if disk.DevPath != "/dev/sda" || disk.Node != "node1" || disk.Instance != "pve1" {
+ t.Fatalf("unexpected fallback disk identity: %+v", disk)
+ }
+ if disk.Health != "PASSED" || disk.Temperature != 30 {
+ t.Fatalf("unexpected fallback disk data: %+v", disk)
+ }
+ return
+ }
+ if time.Now().After(deadline) {
+ t.Fatalf("expected fallback physical disk from host agent SMART, got %+v", disks)
+ }
+ time.Sleep(10 * time.Millisecond)
+ }
+}