Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Use deliberate noncritical temperature continuity controls
pulse-triage[bot]f7622aea48ab
diff --git a/docs/release-control/v6/internal/subsystems/alerts.md b/docs/release-control/v6/internal/subsystems/alerts.mdindex 2083df26fc..c2229a562f 100644--- a/docs/release-control/v6/internal/subsystems/alerts.md+++ b/docs/release-control/v6/internal/subsystems/alerts.md@@ -3703,7 +3703,9 @@ consecutive omissions; empty/expired inventory breaks that confirmation sequenceConfiguration saves reset pending-only runs when global agent policy, host orinherited node/guest overrides, or the applicable disk-type threshold disables-evaluation, even if no report arrives before re-enablement. Only live pending+evaluation, even if no report arrives before re-enablement. Existing known-type+default normalisation is unchanged; the zero-type save control uses a custom+type whose zero threshold the normaliser preserves. Only live pendingidentity/link/type context is retained; unrelated saves preserve a known enabledrun and explicit overrides retain precedence over type defaults. Restored intentwithout that context restarts conservatively on a save rather than inventingdiff --git a/internal/alerts/host_unraid_lifecycle_test.go b/internal/alerts/host_unraid_lifecycle_test.goindex 0ced00d816..780c72c4f1 100644--- a/internal/alerts/host_unraid_lifecycle_test.go+++ b/internal/alerts/host_unraid_lifecycle_test.go@@ -901,7 +901,7 @@ func TestDiskTemperaturePendingConfigDisablement(t *testing.T) {for _, scope := range []string{"global", "all-agents", "host", "node", "vm", "container", "type", "unrelated"} {t.Run(fmt.Sprintf("%s/explicit=%v", scope, explicit), func(t *testing.T) {m, elapsed := continuityManager(t, explicit)- host := hostWithSMARTDiskTemp("pending-temp", "sata", 85)+ host := hostWithSMARTDiskTemp("pending-temp", "custom", 85)host.LinkedNodeID, host.LinkedVMID, host.LinkedContainerID = "site:node", "site:node:101", "site:node:102"id := hostDiskTemperatureResourceID(host.ID, host.Sensors.SMART[0].Device)m.CheckHost(host)@@ -927,7 +927,7 @@ func TestDiskTemperaturePendingConfigDisablement(t *testing.T) {m.CheckHost(host)cfg.Overrides[host.LinkedContainerID] = ThresholdConfig{DiskTemperature: &HysteresisThreshold{Trigger: 0}}case "type":- cfg.DiskTempByType = map[string]HysteresisThreshold{"sata": {Trigger: 0}}+ cfg.DiskTempByType = map[string]HysteresisThreshold{"custom": {Trigger: 0}}case "unrelated":cfg.Schedule.QuietHours.Timezone = "UTC"}@@ -941,7 +941,7 @@ func TestDiskTemperaturePendingConfigDisablement(t *testing.T) {}cfg.Enabled, cfg.DisableAllAgents = true, falsecfg.Overrides = map[string]ThresholdConfig{}- cfg.DiskTempByType = nil+ cfg.DiskTempByType = map[string]HysteresisThreshold{"custom": {Trigger: 80, Clear: 70}}m.UpdateConfig(cfg)elapsed.Store(int64(2 * time.Minute))m.CheckHost(host)@@ -1019,9 +1019,9 @@ func TestDiskTemperatureCurrentCollectionAndOverrideControls(t *testing.T) {}t.Run("host override wins over disabled type", func(t *testing.T) {m, elapsed := continuityManager(t, false)- host := hostWithSMARTDiskTemp("override-temp", "sata", 85)+ host := hostWithSMARTDiskTemp("override-temp", "custom", 85)cfg := m.GetConfig()- cfg.DiskTempByType = map[string]HysteresisThreshold{"sata": {Trigger: 0}}+ cfg.DiskTempByType = map[string]HysteresisThreshold{"custom": {Trigger: 0}}cfg.Overrides[host.ID] = ThresholdConfig{DiskTemperature: &HysteresisThreshold{Trigger: 80, Clear: 70}}m.UpdateConfig(cfg)m.CheckHost(host)diff --git a/internal/alerts/metric_observation_continuity_test.go b/internal/alerts/metric_observation_continuity_test.goindex c916050b51..6ba596e8da 100644--- a/internal/alerts/metric_observation_continuity_test.go+++ b/internal/alerts/metric_observation_continuity_test.go@@ -26,7 +26,7 @@ func continuityManager(t *testing.T, explicit bool) (*Manager, *atomic.Int64) {cfg.GuestDefaults.Memory = &HysteresisThreshold{Trigger: 80, Clear: 70}cfg.GuestDefaults.Disk = &HysteresisThreshold{Trigger: 80, Clear: 70}cfg.AgentDefaults.DiskTemperature = &HysteresisThreshold{Trigger: 80, Clear: 70}- cfg.DiskTempByType = nil+ cfg.DiskTempByType = map[string]HysteresisThreshold{"sata": {Trigger: 80, Clear: 70}, "custom": {Trigger: 80, Clear: 70}}cfg.AgentDefaults.Memory = &HysteresisThreshold{Trigger: 80, Clear: 70}m.UpdateConfig(cfg)elapsed := &atomic.Int64{}