Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Record why a disk's operator state does not follow its ID
rcourtmanf983b8c08f20
diff --git a/docs/release-control/v6/internal/subsystems/unified-resources.md b/docs/release-control/v6/internal/subsystems/unified-resources.mdindex 8b6b812a3c..592d95431a 100644--- a/docs/release-control/v6/internal/subsystems/unified-resources.md+++ b/docs/release-control/v6/internal/subsystems/unified-resources.md@@ -3759,12 +3759,54 @@ one must first make the lock follow the disk;registry's producers does (a Proxmox disk, an agent's SMART disk, an Unraidarray disk, a record-fed disk), and `TestProviderDiskRecordsAdvertiseNoActionCapability`in `internal/truenas/provider_test.go` when the TrueNAS provider's records do.-The disk's other operator settings (retirement, maintenance, notes) are+The disk's other operator settings (retirement, muting, maintenance windows,+criticality, notes) are not carried either, and that is a decision, not a gap.+The readers that resolve a disk's reference (alert intent, Patrol's+operator-state provider, the resources API and the agent resource context) read+the row of the ID it resolves to, so after the re-key they read none unless a+row already sits on that scoped ID (a row written on a scoped ID applies again+whenever a copy with the same serial and machine scope is scoped again). On the+rebuild after the other machine's copy goes away the disk takes the unscoped ID+back and its original row applies again, over anything written on the scoped ID+since. A row left on an ID the disk no longer holds stays stored (the+maintenance sentinel still enumerates every persisted row, and a read that+names the ID literally still finds it), but resolving the live disk's reference+does not select it. The registry cannot tell which copy a row was set for: one+disk seen from two machines (a dual-ported SAS shelf) and two disks behind one+serial (fixed-serial USB bridges, cloned VMs with an explicit serial) look+alike. Carrying the row to one copy, say the one that held the unscoped ID,+picks a winner without knowing which disk the operator meant. Carrying it to+every copy, as a split recorded against the unscoped ID applies to every copy,+is right for the shelf and wrong for the two disks, and the outcomes differ in+kind: an exclusion that reaches an extra copy only costs an extra row, but a+retirement or mute that reaches a disk the operator never silenced can hide+that disk's failure alerts. Leaving the row makes the disk eligible to alert+again at the split, and the operator sets the posture on the copy. It is not+safe throughout: when the other machine goes away the original row applies+again, and if the operator had written a row on the scoped ID that suppresses+less (a restored monitoring state, a shorter window) the original silences the+disk again over it. That is accepted because the sequence it takes is narrow (a+split, such a write, and the other machine leaving) and the fixes considered all+need more. A copy that keeps the original would bring a cleared row back at the+next rebuild unless a durable record says it was made (a clear deletes the row),+and a move needs a policy for the return; a read-side fallback to the unscoped+row needs no record but extends one disk's posture to unrelated disks and+cannot be cleared per copy; keeping a serial scoped once it has split, so the+unscoped ID does not return, needs a durable marker and its own policy for a+scope that changes when the machine resolves. No report of a posture lost this+way is known (#1516 and #1654 concern missing and duplicated disks). Revisit on+such a report, or when a disk gains an action capability, which already+requires the lock to follow the disk (above).+`TestPhysicalDiskOperatorStateIsNotCarriedAcrossASerialSplit` drives the monitor+adapter's rebuild on both stores and reads as alert intent does; it does not run+the API write path, Patrol's provider or the other readers, so a carry added+there is for review to catch. In short, the disk's other operator settings areorphaned by the same re-key and are not carried. Proof:`TestRemediationLockHoldsOnTheRetiredIDWhileThePreviousGenerationServes`,`TestReporterGainingAStrongKeyKeepsItsRemediationLock`,`TestReporterEraIsDeclaredOnlyForAKeyTheReporterGains`,`TestPhysicalDiskResourcesAdvertiseNoActionCapability`,+`TestPhysicalDiskOperatorStateIsNotCarriedAcrossASerialSplit`,`TestResourceRegistry_ManualLinkFoldKeepsRemediationLock`,`TestResourceRegistry_ManualLinkFoldLockLeavesSurvivorSettings`,`TestLinkedComponentSharesRemediationLockThroughLinksAndUnlinks`,@@ -5823,7 +5865,9 @@ its unscoped ID, apart from observations an operator split off. Residuals: likeany serial-keyed ID, the unscoped ID still passes to a same-serial disk thatappears once the previous holder is gone; a disk's ID changes when asame-serial disk first appears on another machine and back when it goes away,-and alert-history rows owned under the unscoped ID do not follow a re-key; a+and alert-history rows owned under the unscoped ID do not follow a re-key, nor+do its operator-state rows, which is a decision (see the remediation-lock+paragraph); adisk two reporters share is scoped to its canonical parent when the identityfirst spans machines, which the fixed ingest order (snapshot sources, thensupplemental records) and source priority decide; and across reporters,diff --git a/internal/unifiedresources/registry_test.go b/internal/unifiedresources/registry_test.goindex fd91ee84d4..c1b03d66fa 100644--- a/internal/unifiedresources/registry_test.go+++ b/internal/unifiedresources/registry_test.go@@ -9178,6 +9178,195 @@ func TestPhysicalDiskResourcesAdvertiseNoActionCapability(t *testing.T) {}}+// A physical disk's operator-state row is keyed by the canonical ID the disk+// holds, and that ID changes: a disk keyed by a serial one machine reports takes+// the unscoped ID, a second machine reporting the serial re-keys every copy to a+// machine-scoped ID, and the unscoped ID returns on the rebuild after the other+// copy goes away. No row moves with it, by decision. The registry cannot tell+// which copy a row was set for (one disk seen from two machines, or two disks+// behind one fixed serial), and a retirement or mute carried onto a disk the+// operator never silenced can hide that disk's failure alerts, where a row left+// behind only makes the disk eligible to alert again at the split. The quiet+// outcome is when the other machine goes away: the original row applies again,+// over anything the operator wrote on the scoped ID since, which the contract+// accepts.+//+// This drives the monitor adapter's rebuild on both stores and reads the way+// alert intent does: ResolveCanonicalResourceID on the alias a PVE disk alert+// carries, then GetResourceOperatorState on the result. It does not run the API+// write path, Patrol's provider or the other readers, so a carry added there+// would not fail here. Rows are compared as JSON, so a carry of any one field+// (a note, a window, SetBy) fails as well as a carry of the row. A change that+// carries disk rows has to reconsider the trade in the disk paragraph of the+// unified-resources contract, not discover it here.+func TestPhysicalDiskOperatorStateIsNotCarriedAcrossASerialSplit(t *testing.T) {+ stores := map[string]func(t *testing.T) ResourceStore{+ "memory": func(t *testing.T) ResourceStore { return NewMemoryStore() },+ "sqlite": func(t *testing.T) ResourceStore {+ store, err := NewSQLiteResourceStore(t.TempDir(), "default")+ if err != nil {+ t.Fatalf("NewSQLiteResourceStore: %v", err)+ }+ t.Cleanup(func() { _ = store.Close() })+ return store+ },+ }+ now := time.Date(2026, 10, 10, 12, 0, 0, 0, time.UTC)+ // A window is active against the wall clock, not the fixture's, so a carry+ // that acts only on an active window cannot go inert as the date passes.+ windowStart := time.Now().UTC().Add(-time.Hour).Truncate(time.Second)+ windowEnd := windowStart.Add(48 * time.Hour)+ alertRef := ProxmoxPhysicalDiskAlertResourceID("pve", "pve2", "/dev/sda")+ // canon renders every field the row persists, normalized as the stores+ // normalize it, so two rows compare equal only when nothing differs.+ canon := func(state ResourceOperatorState) string {+ state = NormalizeResourceOperatorState(state)+ state.SetAt = state.SetAt.UTC()+ for _, at := range []**time.Time{&state.MaintenanceStartAt, &state.MaintenanceEndAt} {+ if *at != nil {+ utc := (*at).UTC()+ *at = &utc+ }+ }+ encoded, err := json.Marshal(state)+ if err != nil {+ t.Fatalf("encode operator state: %v", err)+ }+ return string(encoded)+ }+ for name, newStore := range stores {+ t.Run(name, func(t *testing.T) {+ store := newStore(t)+ // One adapter, rebuilt by every step as the monitor rebuilds it.+ adapter := NewMonitorAdapter(NewRegistry(store))+ ingest := func(at time.Time, nodes ...string) map[string]Resource {+ t.Helper()+ adapter.PopulateFromSnapshot(sharedSerialDiskSnapshot(at, false, nodes...))+ return sharedSerialDisksByNode(t, adapter.currentRegistry())+ }+ row := func(id string) (ResourceOperatorState, bool) {+ t.Helper()+ state, found, err := store.GetResourceOperatorState(id)+ if err != nil {+ t.Fatalf("read operator state of %s: %v", id, err)+ }+ return state, found+ }+ // What alert intent reads for pve2's disk: the alert reference+ // resolved to a canonical ID, then that ID's row.+ seen := func() (string, ResourceOperatorState, bool) {+ t.Helper()+ id, ok := adapter.ResolveCanonicalResourceID(alertRef)+ if !ok {+ t.Fatalf("alert reference %s does not resolve", alertRef)+ }+ state, found, err := adapter.GetResourceOperatorState(id)+ if err != nil {+ t.Fatalf("read operator state of %s: %v", id, err)+ }+ return id, state, found+ }+ isRow := func(label string, got ResourceOperatorState, found bool, want ResourceOperatorState) {+ t.Helper()+ if !found {+ t.Errorf("%s: no row, want %s", label, canon(want))+ return+ }+ if canon(got) != canon(want) {+ t.Errorf("%s: row is %s, want %s", label, canon(got), canon(want))+ }+ }++ unscoped := ingest(now, "pve2")["pve2"].ID+ retired := ResourceOperatorState{+ CanonicalID: unscoped, LifecycleState: LifecycleStateRetired, MonitoringMode: MonitoringModeMuted,+ NeverAutoRemediate: true, Criticality: CriticalityHigh, Note: "retired after the RMA",+ AutoRemediationPolicy: AutoRemediationPolicy{+ Enabled: true, CapabilityNames: []string{"restart"},+ Window: &AutoRemediationWindow{Timezone: "UTC", StartMinute: 60, EndMinute: 120},+ },+ MaintenanceStartAt: &windowStart, MaintenanceEndAt: &windowEnd, MaintenanceReason: "shelf swap",+ SetAt: now, SetBy: "operator",+ }+ if err := store.SetResourceOperatorState(retired); err != nil {+ t.Fatalf("retire the disk: %v", err)+ }+ id, state, found := seen()+ if id != unscoped {+ t.Fatalf("one machine: the alert reference reads %s, want %s", id, unscoped)+ }+ isRow("one machine: the alert reference's row", state, found, retired)++ copies := ingest(now.Add(time.Minute), "pve2", "pve3")+ if len(copies) != 2 || copies["pve2"].ID == unscoped || copies["pve3"].ID == unscoped || copies["pve2"].ID == copies["pve3"].ID {+ t.Fatalf("second machine: copies %s and %s, want two machine-scoped IDs apart from %s", copies["pve2"].ID, copies["pve3"].ID, unscoped)+ }+ for node, disk := range copies {+ if _, found := row(disk.ID); found {+ t.Errorf("second machine: the %s copy %s holds a row set on the unscoped ID", node, disk.ID)+ }+ }+ if id, _, found := seen(); id != copies["pve2"].ID || found {+ t.Errorf("second machine: the alert reference reads %s (row %v), want %s with no row", id, found, copies["pve2"].ID)+ }+ state, found = row(unscoped)+ isRow("second machine: the unscoped ID's row", state, found, retired)++ // The operator writes a row on pve2's copy: a note and a recurring+ // window, which also puts the copy back to active monitoring.+ scoped := copies["pve2"].ID+ restored := ResourceOperatorState{+ CanonicalID: scoped, Note: "pve2 copy restored",+ MaintenanceRecurrence: &RecurringMaintenanceWindow{Timezone: "UTC", Weekdays: []string{"monday"}, StartMinute: 60, EndMinute: 120},+ SetAt: now.Add(2 * time.Minute), SetBy: "second-operator",+ }+ if err := store.SetResourceOperatorState(restored); err != nil {+ t.Fatalf("write the pve2 copy's row: %v", err)+ }+ reordered := ingest(now.Add(3*time.Minute), "pve3", "pve2")+ if reordered["pve2"].ID != scoped || reordered["pve3"].ID != copies["pve3"].ID {+ t.Fatalf("ingest order moved the copies: pve2 %s -> %s, pve3 %s -> %s", scoped, reordered["pve2"].ID, copies["pve3"].ID, reordered["pve3"].ID)+ }+ if _, found := row(copies["pve3"].ID); found {+ t.Errorf("the pve3 copy %s holds a row though none was set on it", copies["pve3"].ID)+ }+ state, found = row(scoped)+ isRow("after the ingest order changed: the pve2 copy's row", state, found, restored)++ if disk := ingest(now.Add(4*time.Minute), "pve2")["pve2"]; disk.ID != unscoped {+ t.Fatalf("other machine gone: the disk holds %s, want the unscoped %s back", disk.ID, unscoped)+ }+ id, state, found = seen()+ if id != unscoped {+ t.Fatalf("other machine gone: the alert reference reads %s, want %s", id, unscoped)+ }+ isRow("other machine gone: the alert reference's row (the original, over the later write)", state, found, retired)+ state, found = row(scoped)+ isRow("other machine gone: the row written on the scoped ID", state, found, restored)+ if _, found := row(copies["pve3"].ID); found {+ t.Errorf("other machine gone: the pve3 copy's ID %s holds a row though none was set on it", copies["pve3"].ID)+ }++ // A row already on a scoped ID applies again whenever a copy with the+ // same serial and machine scope is scoped again.+ again := ingest(now.Add(5*time.Minute), "pve2", "pve3")+ if again["pve2"].ID != scoped || again["pve3"].ID != copies["pve3"].ID {+ t.Fatalf("second split: copies %s and %s, want the earlier %s and %s", again["pve2"].ID, again["pve3"].ID, scoped, copies["pve3"].ID)+ }+ id, state, found = seen()+ if id != scoped {+ t.Fatalf("second split: the alert reference reads %s, want %s", id, scoped)+ }+ isRow("second split: the alert reference's row", state, found, restored)+ state, found = row(unscoped)+ isRow("second split: the unscoped ID's row", state, found, retired)+ if _, found := row(copies["pve3"].ID); found {+ t.Errorf("second split: the pve3 copy %s holds a row though none was set on it", copies["pve3"].ID)+ }+ })+ }+}+// A succession batch is applied in the order it is declared, and each group of// linked IDs it saved follows only the re-keys applied after it. A batch// declared against its direction, and one that returns an ID to its start, both