Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
fix(memory): use linked Pulse host agent memory to avoid VM inflation (#1270)
rcourtmanfb7582c7e4fe
diff --git a/internal/monitoring/diagnostic_snapshots.go b/internal/monitoring/diagnostic_snapshots.goindex db8a937073..1ed9a9279c 100644--- a/internal/monitoring/diagnostic_snapshots.go+++ b/internal/monitoring/diagnostic_snapshots.go@@ -62,6 +62,8 @@ type VMMemoryRaw struct {MemInfoTotalMinusUsed uint64 `json:"meminfoTotalMinusUsed,omitempty"`Agent int `json:"agent,omitempty"`DerivedFromBall bool `json:"derivedFromBalloon,omitempty"`+ HostAgentTotal uint64 `json:"hostAgentTotal,omitempty"`+ HostAgentUsed uint64 `json:"hostAgentUsed,omitempty"`}// GuestMemorySnapshot records the memory calculation for a guest (VM/LXC).diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.goindex cd90ff7ee6..e1b2b3a34b 100644--- a/internal/monitoring/monitor.go+++ b/internal/monitoring/monitor.go@@ -6707,6 +6707,17 @@ func (m *Monitor) pollVMsAndContainersEfficient(ctx context.Context, instanceNam}}+ // Build a lookup map from VM guest ID → linked host agent.+ // When a Pulse agent runs inside a VM, it reads /proc/meminfo directly+ // and gets accurate MemAvailable (excluding page cache). We use this as+ // a memory fallback before the inflated status.Mem value. Refs: #1270+ vmIDToHostAgent := make(map[string]models.Host)+ for _, h := range prevState.Hosts {+ if h.LinkedVMID != "" && h.Status == "online" && h.Memory.Total > 0 {+ vmIDToHostAgent[h.LinkedVMID] = h+ }+ }+var allVMs []models.VMvar allContainers []models.Container@@ -6845,6 +6856,30 @@ func (m *Monitor) pollVMsAndContainersEfficient(ctx context.Context, instanceNam}}+ // Fallback: use linked Pulse host agent's memory data.+ // gopsutil's Used = Total - Available (excludes page cache),+ // so we can derive accurate available memory. Refs: #1270+ if memAvailable == 0 {+ if agentHost, ok := vmIDToHostAgent[guestID]; ok {+ agentAvailable := agentHost.Memory.Total - agentHost.Memory.Used+ if agentAvailable > 0 {+ memAvailable = uint64(agentAvailable)+ memorySource = "host-agent"+ guestRaw.HostAgentTotal = uint64(agentHost.Memory.Total)+ guestRaw.HostAgentUsed = uint64(agentHost.Memory.Used)+ log.Debug().+ Str("vm", res.Name).+ Str("node", res.Node).+ Int("vmid", res.VMID).+ Uint64("total", memTotal).+ Uint64("available", memAvailable).+ Int64("agentTotal", agentHost.Memory.Total).+ Int64("agentUsed", agentHost.Memory.Used).+ Msg("QEMU memory: using linked Pulse host agent memory (excludes page cache)")+ }+ }+ }+switch {case memAvailable > 0:if memAvailable > memTotal {diff --git a/internal/monitoring/monitor_polling.go b/internal/monitoring/monitor_polling.goindex 8eac60ba2c..06bbf119fd 100644--- a/internal/monitoring/monitor_polling.go+++ b/internal/monitoring/monitor_polling.go@@ -214,6 +214,18 @@ func (m *Monitor) pollVMsWithNodes(ctx context.Context, instanceName string, cluInt("onlineNodes", onlineNodes).Msg("Starting parallel VM polling")+ // Build a lookup map from VM guest ID → linked host agent.+ // When a Pulse agent runs inside a VM, it reads /proc/meminfo directly+ // and gets accurate MemAvailable (excluding page cache). We use this as+ // a memory fallback before the inflated status.Mem value. Refs: #1270+ prevState := m.GetState()+ vmIDToHostAgent := make(map[string]models.Host)+ for _, h := range prevState.Hosts {+ if h.LinkedVMID != "" && h.Status == "online" && h.Memory.Total > 0 {+ vmIDToHostAgent[h.LinkedVMID] = h+ }+ }+// Launch a goroutine for each online nodefor _, node := range nodes {// Skip offline nodes@@ -358,6 +370,31 @@ func (m *Monitor) pollVMsWithNodes(ctx context.Context, instanceName string, clu// confusion (showing 1GB/1GB at 100% when VM is configured for 4GB)// and makes the frontend's balloon marker logic ineffective.// Refs: #1070++ // Fallback: use linked Pulse host agent's memory data.+ // gopsutil's Used = Total - Available (excludes page cache),+ // so we can derive accurate available memory. Refs: #1270+ if memAvailable == 0 {+ if agentHost, ok := vmIDToHostAgent[guestID]; ok {+ agentAvailable := agentHost.Memory.Total - agentHost.Memory.Used+ if agentAvailable > 0 {+ memAvailable = uint64(agentAvailable)+ memorySource = "host-agent"+ guestRaw.HostAgentTotal = uint64(agentHost.Memory.Total)+ guestRaw.HostAgentUsed = uint64(agentHost.Memory.Used)+ log.Debug().+ Str("vm", vm.Name).+ Str("node", n.Node).+ Int("vmid", vm.VMID).+ Uint64("total", memTotal).+ Uint64("available", memAvailable).+ Int64("agentTotal", agentHost.Memory.Total).+ Int64("agentUsed", agentHost.Memory.Used).+ Msg("QEMU memory: using linked Pulse host agent memory (excludes page cache)")+ }+ }+ }+switch {case memAvailable > 0:if memAvailable > memTotal {