Fine-tune LLMs from one YAML. Layer streaming trains an 8B model on a 4 GB laptop GPU.
Probe — does the second NVMe add read bandwidth? (disk-tier read rate, R1)
Status: decision rule committed 2026-09-28, BEFORE the run. NO FORMAL VERDICT: the rule's
validity row fired in all three runs (§5), and D1, D2 and R3' are ambiguous by their own rules.
The two-drive read rate it records is a measurement, not a verdict. Striping (R4) was gated on
its own, on the training step: gate-two-drive-striping.md.
(Status line updated 2026-10-01; until then it read "Results pending".)
0. The question, and why it decides a feature
The cold 70B-shaped step on this box is bound by the read outright: 17.0-17.2 s
at seq 512 AND at seq 256, while the compute floor with the read removed halves
(6.4 -> 3.8 s). The step moves 70.38 GB at 4.09-4.14 GB/s averaged
(probe-rtx5070-what-bounds-streaming.md §21, Finding 21). One drive's
unbuffered cold ceiling is 5.65 GB/s at K = 2-4 parallel ranges (gate-974 §4).
So on one drive the step cannot go below ~12.5 s whatever the reader does.
The box has TWO drives, and the disk tier reads from one: the NF4 shard caches
live on C:, the bf16 fixtures on D:. If the two deliver 2x together, a store
striped across both could take the 70B step to its compute floor (6.5 s at
1x512), and every giant-MoE row in the roadmap's L2L table falls by the same
factor, because those rows are read seconds x compute ceiling tokens per step.
If the drives share a bottleneck, striping is work for nothing. The roadmap has
said "a second NVMe halves it" since 2026-09-24; nobody measured it. This does,
before any sharder or reader code changes.
1. The two drives and where they attach
| C: | D: | |
|---|---|---|
| physical disk | 0 | 1 |
| model | Samsung MZAL81T0HFLB-00BL2 (PM9B1), 954 GB | same |
| filled | 730 GB used, 224 GB free | 156 GB used, 798 GB free |
| controller location | PCIROOT(0)#PCI(0600)#PCI(0000) |
PCIROOT(0)#PCI(1D04)#PCI(0000) |
| root port | PEG0 = 00:06.0, Intel 8086:A74D — a CPU root port |
RP13 = 00:1D.4, Intel 8086:7A34 — a chipset (PCH) root port |
| path to memory | CPU lanes directly | the DMI 4.0 x8 link (~15.75 GB/s), shared with the chipset's other devices |
| what lives there | the NF4 shard caches (two 70B stores, 36.4 GB each) | the bf16 fixtures (138 GB 70B-shaped, 27.5 GB 14B-shaped) |
The CPU is an i9-14900HX (Raptor Lake HX). One drive on CPU lanes and one behind the chipset is the usual layout on this class of laptop, and it is the reason the answer is not obvious either way: DMI 4.0 x8 carries ~15.75 GB/s, enough for one drive with room to spare, but it is not the drive's own link.
2. The decision rule, written before the run
Inputs, per round, at K = 4 ranges per span (the reader's default
read_ranges): alone_A, alone_B — each drive reading alone; rate_A,
rate_B — each drive's rate in the both-at-once arm, over the window in which
BOTH were reading. Then
r_sum = (rate_A + rate_B) / max(alone_A, alone_B) # weighted striping's ceiling
r_alt = 2 x min(rate_A, rate_B) / max(alone_A, alone_B) # plain alternate-layer striping
The rule reads the median over three rounds. A = C:, B = D:.
| measured (medians) | verdict | what follows |
|---|---|---|
alone_A outside 4.5-6.2 GB/s |
the instrument does not reproduce gate-974's 5.1-5.65 GB/s at K = 2-4 on this drive | no verdict. Record the run, find out why, re-run. A comparison of two drives on a session that does not reproduce the known one is not evidence |
r_sum >= 1.6 AND r_alt >= 1.6 |
the drives are independent | build plain alternate-layer striping (layer i on drive i mod 2) in the sharder and the reader, gated bit-exact against the single-drive disk tier. Predicted 70B step: max(70.38 GB / (r_alt x 4.1 GB/s), 6.4 s) — a prediction until the step measures it |
r_sum >= 1.6 > r_alt |
independent but unequal | build weighted striping (bytes per drive in proportion to its rate — Colibri's 9 + 3 GB/s scheme); plain alternation would leave the difference on the table |
1.2 <= r_sum < 1.6 |
partly shared | do not build yet. Measure where the reader loses 4.1 vs 5.65 GB/s on one drive first (R3): that gap is worth 1.37x with no layout change, and the second drive is worth r_sum at most |
r_sum < 1.2 |
a shared bottleneck | do not build. The second drive is capacity, not bandwidth; say so in the roadmap and stop |
Why 1.6. 2.0 is perfect. At 1.6 the 70B step's read goes from 17 s to
~10.7 s at today's reader efficiency — a 1.6x step for a sharder-layout change
and a reader change, which is worth building. Below it the gain is smaller than
what the single-drive reader gap (R3, 1.37x) and pinned RAM residency (1.5x
at ~12 GB resident, an estimate) offer without touching the layout, so it does
not go first.
What the rule does NOT decide, stated before the numbers so none of it is read into them afterwards: whether the reader reaches this rate inside the real step (R3 and the striping gate measure that); the host-to-device side (at 2 x 5.65 GB/s the copy needs ~11 GB/s, against ~16.7 GB/s pinned H2D); sustained reads past a few seconds (thermal throttling of a DRAM-less drive is not exercised by ~2 s arms).
3. Instrument
two_drive_read.py, the #974 primitive:CreateFileW(FILE_FLAG_NO_BUFFERING | FILE_FLAG_SEQUENTIAL_SCAN), one handle per range, oneReadFileper range, into a sector-aligned pinned arena (one per drive). Unbuffered reads never touch the page cache, so there is nothing to evict and every read is cold.- A span = 400 MiB, sector-aligned, wholly inside one file — the size of one 70B NF4 layer file (those are ~430 MB; the span is their first 400 MiB). On C: the spans are the layer files of the two 70B NF4 stores in file order; on D: consecutive 400 MiB windows of the bf16 fixtures. Each span is read as K = 4 parallel ranges of 100 MiB, and the next span starts when all four have landed — the reader's shape. No span is read twice in a run.
- Per drive: one untimed warm-up span. Then three rounds; each round runs A alone, B alone and both at once, 24 spans (10.07 GB) per drive per arm, in an order that rotates so each arm runs first once.
- In the both-at-once arm the two drives start from a barrier. Each drive's rate is its bytes inside the window where both were reading, divided by the window; a span that straddles the window's end is pro-rated. Aggregate over the whole arm and each drive's own whole-arm rate are recorded beside it.
- Byte check after every arm: the first and last MiB of the last span read into each arena against a buffered read of the same offsets. A mismatch makes the run exit non-zero.
4. Box state
This runs beside the contributor loop's own sessions (pytest suites and auto-merge loops) and a separate local project's llama-server. Each round stamps available physical memory, commit, the Python process count and the GPU's memory/utilisation/temperature into the JSON. The validity row in §2 is what catches a session contaminated by someone else's I/O.
5. Results
Run 1 — 2026-09-28 10:28, NO VERDICT: the validity row fired
JSON benchmarks/results/probe-rtx5070/two-drive/r1_k4.json; soup_cli
stamped from this worktree (Soup-read\src); every byte check OK. GB/s:
| round (order) | A = C: alone | B = D: alone | both: A | both: B | both: aggregate | window (s) | r_sum | r_alt |
|---|---|---|---|---|---|---|---|---|
| 0 (a, b, ab) | 3.62 | 4.27 | 3.64 | 4.95 | 7.65 | 2.03 | 2.014 | 1.707 |
| 1 (b, ab, a) | 3.94 | 3.94 | 4.04 | 5.27 | 7.90 | 1.91 | 2.362 | 2.049 |
| 2 (ab, a, b) | 3.85 | 5.83 | 4.46 | 5.75 | 8.69 | 1.75 | 1.751 | 1.529 |
| median | 3.855 | 4.266 | 4.035 | 5.270 | — | — | 2.014 | 1.707 |
Verdict under §2: none. alone_A = 3.855 GB/s is outside 4.5-6.2. The
r medians would sit in the "independent drives" row, and they are not read as
a verdict: the rule says a comparison made on a session that does not
reproduce the known drive is not evidence, and it was written before this run
for exactly this case.
What the run's own stamps show about why. At the start the box had
3.03 GB of available physical memory and commit 56.65 GB against a limit of
56.69 — at the limit, with the pagefile expanded (the rounds then read
3.18 / 3.89 / 4.89 GB available, commit 56.6 / 53.8 / 51.0). The pagefile is
C:\pagefile.sys (peak use since boot 9.7 GB). gate-974's unbuffered rows were
measured at 19.34 GB free and commit 21.6 of 47.35 GB. This run logged no disk
counters, so paging I/O on C: during the arms is a hypothesis, not a
measurement. Two patterns fit it and neither proves it: C: was the slower
drive in two of the three alone pairs and tied in the third, while D: — which
nothing else touches — reached 6.5 GB/s on single spans and a 6.05 GB/s median
per span in round 2, above anything gate-974 recorded on C:; and each drive
read faster in the both-at-once arm than alone in five of six comparisons,
which a shared bottleneck cannot produce and which points at the host (CPU
power state, background load) rather than at the drives. That last pattern is
not explained here.
A defect in the rule's validity row, found while diagnosing — disclosed, NOT corrected. The 4.5-6.2 GB/s bound was derived from a summary of gate-974 ("5.1-5.65 GB/s at K = 2-4") that had kept its best readings. gate-974 §4's own K = 4, one-request-per-range readings are 5.12 GB/s (run A, layers 12-17) and 4.18 (run B, layers 54-59), its K = 2-8 one-request readings span 4.02-5.30, and it calls the difference a 20-30% drive/position effect. The committed bound is therefore tighter than the reference it names: a quiet-box C: reading of ~4.2 GB/s would fail it while matching gate-974's own run B. The row stays as committed — changing a validity bound after seeing the numbers it rules on is what pre-registration exists to prevent. If a later run lands between 4.0 and 4.5 GB/s on a quiet box, the record says so and the call goes to the owner.
Instrument change before run 2 (the rule is unchanged): the harness now
samples Windows performance counters through PDH every 0.25 s on a background
thread — LogicalDisk read and write bytes per volume, Memory\Pages/sec and
Committed Bytes, Processor\% Processor Time and Processor Information\% Processor Performance (the actual clock as a share of nominal). The harness
only reads, so a write on either volume during an arm is someone else's
I/O; the read counter cross-checks the harness's own rate. Also fixed: the
box stamp's Python-process count was lost to a decoding error (tasklist
prints in the OEM code page, and the no-break space in its memory column is
0xFF in cp866), so run 1's python_processes is null.
Run 2 — 2026-09-28 10:35, NO VERDICT again, and foreign I/O is ruled out
JSON r1_k4_run2.json; same rule, same spans as run 1 (the span list starts
from the top of each drive's files every run, so run 2 re-read run 1's bytes —
irrelevant to an unbuffered read of a drive with no DRAM cache, and stated so
it is not discovered later); every byte check OK; no counter errors. The box
this time: 5.26 GB available, commit 49.3 of 56.6 GB at the start (5.3 / 6.3 /
5.9 GB and 49.3 / 46.4 / 47.4 GB in the rounds), 12-13 Python processes (the
contributor loop's suites and watchers).
| round (order) | A = C: alone | B = D: alone | both: A | both: B | both: aggregate | window (s) | r_sum | r_alt |
|---|---|---|---|---|---|---|---|---|
| 0 (a, b, ab) | 3.89 | 4.35 | 3.92 | 4.91 | 8.07 | 2.05 | 2.031 | 1.803 |
| 1 (b, ab, a) | 3.99 | 4.33 | 4.15 | 5.34 | 8.26 | 1.88 | 2.192 | 1.917 |
| 2 (ab, a, b) | 4.11 | 6.02 | 4.79 | 5.69 | 9.15 | 1.77 | 1.741 | 1.592 |
| median | 3.990 | 4.351 | 4.149 | 5.341 | — | — | 2.031 | 1.803 |
Verdict under §2: none — alone_A = 3.990 GB/s, outside 4.5-6.2, and also
0.03 below the 4.02 floor of gate-974's own one-request readings, so it is not
the "between 4.0 and 4.5" case the run-1 note hands to the owner either.
What the counters settle. Writes on C: during the C:-alone arms averaged 1.2 / 1.8 / 0.2 MB/s and during the both-at-once arms 10.4 / 0.1 / 7.0 MB/s — against 3.7-4.4 GB/s of reads, i.e. foreign I/O on C: is not why C: reads ~4 GB/s, and neither is paging (136-689 pages/s in the C: arms, a few MB/s). The CPU was not asleep either: 10-23% busy, clock 136-154% of nominal in every arm. The read counter agrees with the harness (3.67 / 3.88 / 4.11 GB/s against 3.89 / 3.99 / 4.11). Two things did NOT change between runs: C: alone stayed at 3.9-4.1, and each drive again read faster beside the other than alone — A in 3 of 3 rounds (3.89 -> 3.92, 3.99 -> 4.15, 4.11 -> 4.79), B in 2 of 3. The r medians reproduce: r_sum 2.014 -> 2.031, r_alt 1.707 -> 1.803. The both-at-once aggregate across the six rounds of the two runs is 7.65-9.15 GB/s, against 5.65 GB/s, the best single-drive primitive reading gate-974 ever recorded on this box.
One host setting found while looking (powercfg, active scheme Balanced
381b4222-...): PCIe Link State Power Management is "Maximum power savings"
on AC as well as on battery (index 2). The NVMe-specific idle settings are
hidden on this image and do not print. So two host mechanisms fit "faster
beside the other drive": the CPU package dropping into a deep idle state
between completions, and each link's ASPM dropping it to L1 between bursts.
D1 — does keeping the CPU awake speed up one drive? (rule written before D1 ran)
A busy loop on another core keeps the CPU package out of its deep idle states
and cannot reach a PCIe link's ASPM, so reading C: alone with and without
spinner processes separates the two mechanisms. Harness
two_drive_host_probe.py (imports two_drive_read.py's primitive, spans,
counters and byte check): per round, rotated, C: alone and C: alone with 2
processes running while True: pass; 24 spans per arm, K = 4, three rounds.
| measured: spin / alone, per round | reading | next |
|---|---|---|
| >= 1.10 in all three rounds | the CPU package's idle state costs >= 10% of one drive's read | a keep-awake measure inside the reader is a software lever that needs no user setting; the owner decides on a controlled power-plan comparison before R1 is re-run |
| 0.95-1.05 in all three rounds | package idle is not it | the remaining host suspect is per-link ASPM, which only a power-plan change tests — owner decision, because it changes a system setting on a shared box |
| anything else | ambiguous | reported as measured; no conclusion drawn |
D1 result — 2026-09-28 10:47, AMBIGUOUS by its own rule. JSON
d1_host_spin.json; every byte check OK; no counter errors.
| round (order) | C: alone | C: alone + 2 spinners | spin / alone | CPU busy (alone / spin) | clock, % of nominal (alone / spin) |
|---|---|---|---|---|---|
| 0 (alone, spin) | 3.91 | 4.14 | 1.059 | 13% / 16% | 142 / 150 |
| 1 (spin, alone) | 3.99 | 4.11 | 1.029 | 7% / 18% | 141 / 149 |
| 2 (alone, spin) | 4.68 | 4.03 | 0.860 | 6% / 18% | 139 / 150 |
| median | 3.993 | 4.108 | 1.029 |
Neither decisive row holds (1.059 and 0.860 fall outside 0.95-1.05, and no round reaches 1.10), so no conclusion is drawn from D1. What it does show, without being a verdict: keeping two cores busy moved the median by +3% and reversed in one round, so the CPU package's idle state is not the ~20% effect the both-at-once arm shows — and C: alone ranged 3.91-4.68 GB/s within ninety seconds with foreign writes at 1.2-1.7 MB/s, i.e. the drive's own spread is as large as the effect being chased. Across all nine C:-alone arms of the day (runs 1, 2, D1) C: read 3.62-4.68 GB/s, median 3.94.
Where R1 stands, stated plainly. The committed rule has given no verdict, twice, and it will not be edited to give one. The one host suspect left is per-link ASPM ("Maximum power savings" on AC), and testing it means changing a power setting on a box other sessions are using, so it waits for the owner. What the record does establish is below any verdict: the two drives read 7.65-9.15 GB/s together in six of six both-at-once arms, each drive at its alone rate or faster, which no shared bottleneck produces.
D2 — does PCIe ASPM slow one drive? (owner's consent 2026-09-28; rule written before D2 ran)
The owner agreed to a short, reversible change of the power setting. Harness
two_drive_aspm_probe.py reads the active scheme's AC ASPM index (2, "Maximum
power savings"), then reads C: alone with the index at 2 ("on") and at 0
("Off"), switching the policy between arms (powercfg /setacvalueindex +
/setactive, read back after every change, 1 s settle), order rotated over
three rounds, 24 spans per arm, K = 4. It refuses to run on battery. The
original index is restored in a finally block and read back; the run exits
non-zero if it disagrees. Then, with ASPM Off, it runs R1 once more (run 3)
through the unchanged two_drive_read.py, and restores again. A write of the
same value (2 -> 2) confirmed beforehand that no elevation is needed.
| measured: off / on, per round | reading | next |
|---|---|---|
| >= 1.10 in all three rounds | ASPM costs >= 10% of one drive's read on this box | a host setting the disk tier's docs (and soup doctor) should name |
| 0.95-1.05 in all three rounds | ASPM is not it | what remains is the drive's own spread |
| anything else | ambiguous | reported as measured; no conclusion |
R1 run 3 is judged by the R1 rule in §2, unchanged — whatever D2 says. If its validity row passes, its verdict row is R1's verdict, stated as holding with ASPM Off; if the row fires again, R1 has no verdict from this box and the decision to build on the aggregate evidence stays the owner's.
First D2 attempt, 2026-09-28 ~10:55: refused, nothing changed. The laptop
had been unplugged (GetSystemPowerStatus ACLineStatus 0, battery 97% and
discharging), and the harness refuses to run on battery because the AC index
is then not the one in force and nothing would be comparable with runs 1-2.
It stopped before reading or writing any power setting. D2 waits for AC.
R3' — does the reader's per-layer barrier cost one drive throughput? (rule written before R3' ran)
Found while reading the reader for R4: AsyncDiskSource._read_layer
(src/soup_cli/utils/async_disk_source.py:688) hands a layer's K ranges to K
workers through _RangeReaders.run, which blocks until every range has landed
before the next layer is dispatched. Exactly one layer is ever in flight, and
workers that finish early idle on the slowest range's tail. Two consequences:
striping the files alone could not speed anything up (layer i on C: and layer
i+1 on D: would still be read one after the other), and the "reader gap" the
roadmap attributed to the pipeline may instead be this barrier — or nothing,
since the same primitive with the same barrier read C: at 3.62-4.68 GB/s today
(median 3.94), which is where the step-level 4.1 GB/s of §21 already sits.
Harness two_drive_depth_probe.py: one drive (C:), K = 4 workers, the same
ranges read through ONE function at depth 1 (the reader today) and depth 2 (the
next span's ranges queued behind the current one's, so a freed worker starts on
it at once). At most K requests are outstanding in either arm; only the barrier
differs. Order rotated over three rounds, 24 spans per arm, on AC only.
| measured: depth 2 / depth 1, per round | reading | next |
|---|---|---|
| >= 1.10 in all three rounds | the barrier costs >= 10% of one drive | two layers in flight is a single-drive lever of its own, and it is the same reader change striping needs — build them together |
| 0.95-1.05 in all three rounds | the barrier costs nothing measurable | the reader already reads at the drive's rate; R3 closes with no single-drive reader lever, and striping still needs >= 2 layers in flight for its own reason |
| anything else | ambiguous | reported as measured; no conclusion |
D2 result — 2026-09-28 13:35, AMBIGUOUS by its own rule; ASPM restored
The laptop was back on AC from 13:26:53 (a background watcher waited for it to
stay plugged in for 60 s; battery 17% and charging). Box at the start: 9.10 GB
available, commit 46.95 of 56.62 GB, 18 Python processes, GPU idle. JSON
d2_aspm.json; every byte check OK; the AC ASPM index read 2 before and 2
after (restored by the harness's finally, then read back independently with
powercfg).
| round (order) | C: ASPM on (2) | C: ASPM Off (0) | off / on | foreign writes on C:, MB/s (on / off) |
|---|---|---|---|---|
| 0 (on, off) | 3.52 | 3.61 | 1.027 | 9.0 / 7.4 |
| 1 (off, on) | 3.59 | 3.57 | 0.996 | 6.4 / 12.1 |
| 2 (on, off) | 3.93 | 3.58 | 0.910 | 2.7 / 4.2 |
| median | 3.588 | 3.582 | 0.996 |
No row decides it (0.910 is outside 0.95-1.05, no round reaches 1.10), so no conclusion is drawn — but no round shows ASPM costing anything like the 10% the rule asked about, and the median is 1.00. ASPM is not why C: reads ~4 GB/s.
R1 run 3, ASPM Off — NO VERDICT for the third time
JSON r1_k4_run3_aspm_off.json, run by D2's harness with ASPM Off; every byte
check OK; foreign writes on C: 2.3-3.9 MB/s in the C: arms.
| round (order) | A = C: alone | B = D: alone | both: A | both: B | both: aggregate | window (s) | r_sum | r_alt |
|---|---|---|---|---|---|---|---|---|
| 0 (a, b, ab) | 3.90 | 4.45 | 3.88 | 4.69 | 7.94 | 2.14 | 1.929 | 1.747 |
| 1 (b, ab, a) | 3.84 | 4.35 | 3.91 | 5.32 | 7.80 | 1.89 | 2.123 | 1.798 |
| 2 (ab, a, b) | 3.73 | 5.73 | 4.27 | 5.82 | 8.45 | 1.73 | 1.761 | 1.491 |
| median | 3.837 | 4.446 | 3.908 | 5.325 | — | — | 1.929 | 1.747 |
alone_A = 3.837 is outside 4.5-6.2: the validity row fired for the third
time, so by the rule committed before run 1, R1 has no verdict from this box.
The decision to build on the aggregate evidence is the owner's, and it was made
the same day on this record: the striping design went ahead, with its own gate
on the real training step (not this primitive) as the shipping criterion.
R3' result — 2026-09-28 13:36, AMBIGUOUS by its own rule
Box at the start: 5.41 GB available, commit 54.48 of 57.71 GB (at the limit
again; the contributor loop's suites were running), 18 Python processes. JSON
r3p_depth.json; every byte check OK.
| round (order) | C: depth 1 (the reader today) | C: depth 2 | d2 / d1 | foreign writes on C:, MB/s (d1 / d2) |
|---|---|---|---|---|
| 0 (d1, d2) | 3.63 | 4.02 | 1.106 | 11.4 / 16.3 |
| 1 (d2, d1) | 3.84 | 4.23 | 1.101 | 8.8 / 8.0 |
| 2 (d1, d2) | 4.52 | 4.36 | 0.963 | 5.9 / 8.0 |
| median | 3.837 | 4.226 | 1.101 |
Two rounds of three clear 1.10 and the third reverses because depth 1 happened to read 4.52 there — the drive's own spread again. No conclusion is drawn; the reading worth keeping is that removing the per-layer barrier did not cost anything in any round, and gained ~10% in two.
What the day's record adds up to
- C: alone read 3.52-4.68 GB/s across twenty-four single-drive arms (runs 1-3, both arms of D1 and of D2, R3' at depth 1; median 3.90), a spread of the same size as every effect the diagnostics were built to find. (Corrected before publication: the commit that introduced this line said "seventeen arms"; counted from the JSON it is twenty-four.) Foreign I/O (counters), CPU idle (D1) and ASPM (D2) are each ruled out or reduced to noise as the cause of C: reading below gate-974's run A; what remains is unexplained and is stated as such. D: — the emptier drive, behind the chipset — read up to 6.02 GB/s alone.
- Together the two drives read 7.65-9.15 GB/s in nine of nine both-at-once arms, r_sum 1.76-2.36 and r_alt 1.49-2.05 per round, medians 2.01 / 2.03 / 1.93 and 1.71 / 1.80 / 1.75 over the three runs.
- For three rounds to resolve a 10% effect, this drive needs a quieter box or more rounds. Every rule in this record was written for three; that choice, not the drives, is why three of its tables end "ambiguous".
6. Verdict
No formal verdict. R1's validity row fired in all three runs (§5, runs 1-3), and the rule
is not edited to give one; D1, D2 and R3' are ambiguous by their own rules. What the record
establishes without a verdict is stated under "What the day's record adds up to" above. The
decision to build striping on that evidence was the owner's (2026-09-28, §5 run 3), with its
own gate on the real training step: gate-two-drive-striping.md.
(Updated 2026-10-01; until then this section read "Pending".)
7. What this does NOT measure
- The streamed step. This is the read primitive on two drives, not the reader and not a training step. A striped reader has to earn its own number.
- The copy to the GPU. Bytes land in pinned host memory and stop there.
- Sustained load. Arms are ~2 s; a DRAM-less drive's thermal throttle under minutes of reads is not exercised.
- Any drive other than these two. Two identical PM9B1 on one CPU and one PCH root port; a desktop with both drives on CPU lanes, or two different drives, is a different measurement.