serve: the engine-exited-before-READY error shows this start's last 20 log lines (#496)

Niko12213af82092d696
diff --git a/serve/server.py b/serve/server.py
index 542ce8f40..3913b1f27 100644
--- a/serve/server.py
+++ b/serve/server.py
@@ -174,6 +174,27 @@ def start_failure_hint(log: str | None, offset: int) -> str:
return ". mtp: " + DRAFT_HEAD_FAIL + ". " + (" ".join(said) if said else "Hint: " + DRAFT_HEAD_HINT)
+def start_log_tail(log: str | None, offset: int, n: int = 20) -> str:
+ """#496: the last n lines this start wrote to the engine log, for the error when the engine ended before READY -
+ whatever the failure, the engine's own reason is in them (people posted the traceback without the log). "" when
+ there is no log or nothing in it from this start."""
+ if not log:
+ return ""
+ try:
+ with open(log, "rb") as f:
+ f.seek(0, 2)
+ start = max(offset, f.tell() - 64 * 1024) # enough for 20 lines, never an earlier start's
+ f.seek(start)
+ text = f.read().decode("utf-8", "replace")
+ except (OSError, ValueError):
+ return ""
+ lines = text.splitlines()[1 if start > offset else 0:] # not a line cut in half
+ lines = [x.rstrip() for x in lines if x.strip()][-n:]
+ if not lines:
+ return ""
+ return "\nthe engine log's last lines:\n" + "\n".join(" " + x for x in lines)
+
+
def echo_requests(log_path: str, offset: int) -> None:
"""STRATA_REQUEST_LINES=1: one stdout line per finished request, from the engine's own summary in its log.
@@ -307,8 +328,16 @@ class StrataEngine:
break
loading.set()
if self.max_context <= 0:
+ try: # its pipes and our handle on its log (the log stays)
+ self.proc.wait(timeout=5)
+ self.proc.stdin.close()
+ self.proc.stdout.close()
+ if log:
+ self.log.close()
+ except (OSError, subprocess.TimeoutExpired):
+ pass
raise RuntimeError("the engine exited before it was ready" + (f" (see {log})" if log else "") +
- start_failure_hint(log, log_start))
+ start_failure_hint(log, log_start) + start_log_tail(log, log_start))
# (from PR #41, midhatn) a locally built engine can sit next to another release's BUILD.json: engines that
# report their own version (INFO engine=, 0.1.8+) win, the manifest stays the fallback for older ones
if self.info.get("engine"):
diff --git a/serve/test_server.py b/serve/test_server.py
index 2099ba9af..2497455ed 100644
--- a/serve/test_server.py
+++ b/serve/test_server.py
@@ -876,6 +876,48 @@ class DraftHeadHint(unittest.TestCase):
self.assertEqual(start_failure_hint(str(Path(tempfile.mkdtemp()) / "missing.log"), 0), "")
+class StartFailureLog(unittest.TestCase):
+ """#496: whatever stopped the engine before READY, the error carries this start's last log lines."""
+
+ def test_the_last_lines_of_this_start(self):
+ from serve.server import start_log_tail
+ d = tempfile.mkdtemp()
+ p = Path(d) / "engine.log"
+ before = "strata serve: an earlier start's line\n"
+ p.write_text(before + "".join(f"strata serve: line {i}\n" for i in range(30)) + "\n"
+ "strata serve: cannot open the pack\n", encoding="utf-8")
+ tail = start_log_tail(str(p), len(before.encode()))
+ self.assertIn("the engine log's last lines:", tail)
+ self.assertIn("cannot open the pack", tail)
+ self.assertIn("line 29", tail)
+ self.assertNotIn("line 10\n", tail + "\n") # 20 lines: 11..29 and the last one
+ self.assertIn("line 11", tail)
+ self.assertNotIn("earlier start", tail)
+ short = start_log_tail(str(p), len(before.encode()), n=3)
+ self.assertEqual(short.count("\n "), 3)
+ self.assertEqual(start_log_tail(str(p), p.stat().st_size), "") # nothing from this start
+ self.assertEqual(start_log_tail(None, 0), "")
+ self.assertEqual(start_log_tail(str(Path(d) / "missing.log"), 0), "")
+
+ def test_the_start_error_has_them(self):
+ import serve.server as server
+ fake = "import sys\nsys.stderr.write('strata serve: cannot open the pack packs/x\\n')\nsys.exit(2)\n"
+ with tempfile.TemporaryDirectory() as d:
+ script, log = Path(d) / "fake_strata.py", Path(d) / "strata.log"
+ script.write_text(fake, encoding="utf-8")
+ log.write_text("an earlier start\n", encoding="utf-8")
+ real = server.subprocess.Popen
+ with mock.patch.object(server.subprocess, "Popen",
+ lambda cmd, **kw: real([sys.executable, str(script), *cmd[1:]], **kw)), \
+ mock.patch.object(server, "narrate_start", lambda *a, **k: None):
+ with self.assertRaises(RuntimeError) as cm:
+ StrataEngine("strata", [], log=str(log))
+ text = str(cm.exception)
+ self.assertIn("exited before it was ready", text)
+ self.assertIn("cannot open the pack packs/x", text)
+ self.assertNotIn("an earlier start", text)
+
+
class CancelledRead(unittest.TestCase):
"""#471: a request cancelled while its prompt was read is recorded with the tokens the engine read (the DONE
line's 15th field), not the whole prompt; an older engine's line (no such field) keeps the whole prompt."""