Open-source Revit MCP server: let Claude and other AI assistants read and edit BIM models, with human approval on every change.
Proof bundles and revert plans
Status: on the dev branch, not yet released.
Every plan that finishes executing leaves a proof file, and an executed parameter fix can be undone through the same approval gate.
Proof bundle
When execute_plan finishes (or a mutating tool marks a plan executed), the server writes proofs/<plan_id>.json in the workspace. Read it with the read-only tool get_proof_bundle(plan_id).
| Field | Meaning |
|---|---|
plan_id, tool, tools |
The plan and the tool(s) it called. |
created_at, approved_at, executed_at |
Lifecycle timestamps (UTC). |
approved_by |
The operating-system account that ran the approval (set by the server; an approver argument is ignored). It is a local account name, not a verified person. approver_note names the channel (panel or cli), or says the identity was not recorded. |
document |
snapshot_id, doc_guid, doc_title of the snapshot the plan was drafted from. null if the plan has no snapshot_id. |
plan_hash |
SHA-256 of the plan content (actions, arguments, before values, skipped list). |
elements |
Applied changes: element_id, uid (when a snapshot is known), parameter, before, before_storage_type (Revit storage type reported when before was captured; null if unknown), new. |
skipped |
Elements left out, each with a reason (blocked at planning time, or failed at execution). Entries from parameter_manager_plan_set_params carry uid, element_id and param. |
outcome |
success, partial or failed. Only success means every action ran. |
To get the document identity and the skipped list, pass snapshot_id (and skipped, which parameter_manager_plan_set_params returns as its blocked list) to plan_actions.
Reverting
plan_revert(plan_id) reads the proof bundle and drafts a new pending plan that sets each parameter back to its recorded before value. It never executes anything: the draft still needs a person to approve it (in the panel or with aec-model-bridge-approve) and then execute_plan, and its own execution gets its own proof (reverts_plan_id links them).
It refuses, with a message, when:
- the plan has no proof bundle, or its outcome is not
success(partial and failed runs are not reverted); - the plan state is not
executed; - an element has no recorded
beforevalue (an empty value counts as not recorded); - the current model value differs from the value the plan wrote. With
allow_conflicts=truethe draft is created anyway and lists those elements in the plan's hashedreviewblock (review.conflicts, with element, parameter, expected, actual and revert-to values clipped for display, plus a warning; conflicts beyond the detailed list are named in an "Also changed" warning), so editing them after drafting invalidates the approval.aec-model-bridge-approve showprints them. The panel does not renderreviewyet.
Values are compared and drafted by type. The live read returns every value as text, so the staleness check compares numerically when both sides are numbers ("60" equals 60, "61" does not) and as text otherwise. The drafted value is rebuilt from before_storage_type: integer for Integer and ElementId, float for Double, text for String. When the storage type was not recorded (proofs written before this field existed), a numeric-looking before becomes a number only if the value the plan wrote was numeric; the draft's review.assumptions list each such guess. The proof bundle also records the plan's hash_version and review.
Like plan_actions, drafting a revert is not itself gated; changing the model is.
Limitations
- UNVERIFIED: write-back to Revit. The tests use an in-memory fake parameter store. The
outcomereflects what the provider reported; the server does not re-read values after writing. Confirm against a live Revit session before relying on it. - UNVERIFIED: revert's staleness check and the
beforecapture read values throughrevit_get_parameter_value, so their correctness in a real model (units, type vs instance parameters, worksharing ownership) depends on that live tool. - When a mutating tool is called directly with a
plan_id(not throughexecute_plan), no per-action results exist. The proof is still written, but its outcome is neversuccess, so such plans cannot be reverted. Direct calls that raise before the plan is marked executed leave no proof. - Only