Open-source Revit MCP server: let Claude and other AI assistants read and edit BIM models, with human approval on every change.
Python aecai-agentsautodeskautomationbimclaudeifcmcpmcp-servermodel-context-protocolnavisworksrevitrevit-addinrevit-apirhino
using System;
using System.Diagnostics;
using System.Net.Http;
using System.Threading;
using System.Threading.Tasks;
using Serilog;
namespace RevitBridge.Bridge;
/// <summary>
/// Ensures the Python MCP hub's panel HTTP shim (packages/mcp-server-revit's
/// panel_server.py) is reachable on 127.0.0.1 before the dockable panel needs it.
///
/// HubClient.cs assumes something is already listening on the panel port — this
/// class is what makes that true on a machine where nobody has manually started
/// `aec-model-bridge-panel-server`. It never manages a hub it didn't start itself:
/// if something is already answering /health (a developer's own instance, or a
/// future bundled-runtime launcher), this leaves it alone entirely, both at
/// startup and at shutdown.
///
/// Python provisioning is not yet bundled with the installer (still open,
/// D-010); this is a best-effort launch matching the interpreter conventions
/// docs/install.md already documents
/// (a project .venv, or a bare `python`/`py` on PATH), not a substitute for that
/// installer work.
/// </summary>
public sealed class PanelHubLauncher
{
private const int HealthCheckTimeoutMs = 800;
private const int PostLaunchPollIntervalMs = 500;
private const int PostLaunchMaxAttempts = 10;
private static readonly HttpClient HealthClient = new HttpClient { Timeout = TimeSpan.FromMilliseconds(HealthCheckTimeoutMs) };
private Process? _launchedProcess;
private static int Port
{
get
{
var raw = Environment.GetEnvironmentVariable("MCP_PANEL_HTTP_PORT");
return int.TryParse(raw, out var port) ? port : 8787;
}
}
/// <summary>
/// Checks whether the panel hub is reachable and launches it in the background
/// if not. Returns immediately; the check/launch/poll sequence runs on a
/// background task so it never blocks Revit's OnStartup.
/// </summary>
public void EnsureRunning()
{
_ = Task.Run(EnsureRunningAsync);
}
private async Task EnsureRunningAsync()
{
if (await IsHealthyAsync().ConfigureAwait(false))
{
Log.Information("Panel hub already reachable on 127.0.0.1:{Port} — not launching a new one", Port);
return;
}
var interpreter = ResolvePythonInterpreter();
if (interpreter == null)
{
Log.Warning(
"Panel hub is not reachable on 127.0.0.1:{Port} and no Python interpreter could be found to " +
"launch it. Set AEC_MODEL_BRIDGE_PYTHON to a python.exe, or start it manually with " +
"'aec-model-bridge-panel-server' / 'python -m revit_mcp_server.panel_server' — see docs/install.md. " +
"The panel will show a connection error until the hub is reachable.",
Port);
return;
}
try
{
var startInfo = new ProcessStartInfo
{
FileName = interpreter,
Arguments = "-m revit_mcp_server.panel_server",
UseShellExecute = false,
CreateNoWindow = true,
// Do NOT redirect stdout/stderr: redirected but unread pipes deadlock
// once the subprocess writes more than ~4KB (the pipe buffer). The hub
// logs at startup so this threshold is reachable. Output is discarded
// anyway — the health-poll loop is the correct readiness signal (H4 fix).
};
// Config() (config.py) requires MCP_REVIT_WORKSPACE_DIR and
// MCP_REVIT_ALLOWED_DIRECTORIES and has no fallback for an installed
// layout with no discoverable .env - without these the subprocess crashed
// on import every time and never became reachable. Respect any value the
// user already has set system-wide; otherwise default to Documents, same
// as install.ps1's own default.json.
SetEnvironmentDefault(startInfo, "MCP_REVIT_MODE", "bridge");
var defaultWorkspace = Environment.GetFolderPath(Environment.SpecialFolder.MyDocuments);
SetEnvironmentDefault(startInfo, "MCP_REVIT_WORKSPACE_DIR", defaultWorkspace);
SetEnvironmentDefault(startInfo, "MCP_REVIT_ALLOWED_DIRECTORIES", defaultWorkspace);
_launchedProcess = Process.Start(startInfo);
Log.Information("Launched panel hub via '{Interpreter} -m revit_mcp_server.panel_server' (pid {Pid})",
interpreter, _launchedProcess?.Id);
}
catch (Exception ex)
{
Log.Warning(ex, "Failed to launch the panel hub with interpreter '{Interpreter}'", interpreter);
return;
}
for (var attempt = 0; attempt < PostLaunchMaxAttempts; attempt++)
{
await Task.Delay(PostLaunchPollIntervalMs).ConfigureAwait(false);
if (await IsHealthyAsync().ConfigureAwait(false))
{
Log.Information("Panel hub is up on 127.0.0.1:{Port}", Port);
return;
}
}
Log.Warning(
"Launched the panel hub but it never became reachable on 127.0.0.1:{Port} after {Attempts} attempts. " +
"Check %LOCALAPPDATA%\\AECModelBridge or the process's own logs for why it failed to start.",
Port, PostLaunchMaxAttempts);
}
private static void SetEnvironmentDefault(ProcessStartInfo startInfo, string name, string defaultValue)
{
if (string.IsNullOrEmpty(Environment.GetEnvironmentVariable(name)))
{
startInfo.EnvironmentVariables[name] = defaultValue;
}
}
private static async Task<bool> IsHealthyAsync()
{
try
{
using var response = await HealthClient.GetAsync($"http://127.0.0.1:{Port}/health").ConfigureAwait(false);
return response.IsSuccessStatusCode;
}
catch
{
return false;
}
}
/// <summary>
/// Finds a Python interpreter capable of running revit_mcp_server, preferring
/// an explicit override, then falling back to whatever's on PATH. Does not
/// search for a project .venv, since the add-in has no reliable way to know
/// where the hub's source checkout lives once installed — that's exactly the
/// gap the bundled-runtime installer (D-010) is meant to close.
/// </summary>
private static string? ResolvePythonInterpreter()
{
var overridePath = Environment.GetEnvironmentVariable("AEC_MODEL_BRIDGE_PYTHON");
if (!string.IsNullOrWhiteSpace(overridePath) && System.IO.File.Exists(overridePath))
{
return overridePath;
}
const string bundledPath = @"C:\ProgramData\AECModelBridge\python\python.exe";
if (System.IO.File.Exists(bundledPath))
{
return bundledPath;
}
foreach (var candidate in new[] { "python", "py" })
{
if (CanRun(candidate))
{
return candidate;
}
}
return null;
}
private static bool CanRun(string command)
{
try
{
using var process = Process.Start(new ProcessStartInfo
{
FileName = command,
Arguments = "--version",
UseShellExecute = false,
CreateNoWindow = true,
RedirectStandardOutput = true,
RedirectStandardError = true,
});
process?.WaitForExit(2000);
return process is { HasExited: true, ExitCode: 0 };
}
catch
{
return false;
}
}
/// <summary>
/// Kills the hub process only if this launcher started it — a hub that was
/// already running before Revit started (a developer's own instance) is left
/// untouched, matching the same restraint EnsureRunning applies at startup.
/// </summary>
public void StopIfLaunched()
{
if (_launchedProcess == null)
{
return;
}
try
{
if (!_launchedProcess.HasExited)
{
_launchedProcess.Kill();
Log.Information("Stopped the panel hub process this launcher started (pid {Pid})", _launchedProcess.Id);
}
}
catch (Exception ex)
{
Log.Warning(ex, "Failed to stop the panel hub process cleanly");
}
finally
{
_launchedProcess.Dispose();
_launchedProcess = null;
}
}
}