Open-source Revit MCP server: let Claude and other AI assistants read and edit BIM models, with human approval on every change.
Python aecai-agentsautodeskautomationbimclaudeifcmcpmcp-servermodel-context-protocolnavisworksrevitrevit-addinrevit-apirhino
feat(addin): launch the panel hub process automatically on startup
A. Sam Mohammad0a6c5cd6d8b6
diff --git a/packages/revit-bridge-addin/src/Bridge/App.cs b/packages/revit-bridge-addin/src/Bridge/App.csindex 3fe0064..127de32 100644--- a/packages/revit-bridge-addin/src/Bridge/App.cs+++ b/packages/revit-bridge-addin/src/Bridge/App.cs@@ -13,6 +13,7 @@ namespace RevitBridge.Bridgeprivate BridgeServer? _server;private CommandQueue? _queue;private ExternalEvent? _externalEvent;+ private PanelHubLauncher? _hubLauncher;public static string? RevitVersion { get; private set; }public static string? ActiveDocumentName { get; private set; }@@ -52,6 +53,17 @@ namespace RevitBridge.BridgeLog.Error(ex, "Bridge started, but the AEC Model Bridge ribbon could not be created");}+ try+ {+ // Fire-and-forget: checks/launches in the background, never blocks startup.+ _hubLauncher = new PanelHubLauncher();+ _hubLauncher.EnsureRunning();+ }+ catch (Exception ex)+ {+ Log.Error(ex, "Bridge started, but the panel hub could not be launched");+ }+application.ControlledApplication.DocumentChanged += (sender, args) =>{ActiveDocumentName = args.GetDocument()?.Title;@@ -303,6 +315,7 @@ namespace RevitBridge.Bridge{try{+ _hubLauncher?.StopIfLaunched();_server?.Stop();_externalEvent?.Dispose();Log.Information("AEC Model Bridge stopped");diff --git a/packages/revit-bridge-addin/src/Bridge/PanelHubLauncher.cs b/packages/revit-bridge-addin/src/Bridge/PanelHubLauncher.csnew file mode 100644index 0000000..e7e23fb--- /dev/null+++ b/packages/revit-bridge-addin/src/Bridge/PanelHubLauncher.cs@@ -0,0 +1,205 @@+using System;+using System.Diagnostics;+using System.Net.Http;+using System.Threading;+using System.Threading.Tasks;+using Serilog;++namespace RevitBridge.Bridge;++/// <summary>+/// Ensures the Python MCP hub's panel HTTP shim (packages/mcp-server-revit's+/// panel_server.py) is reachable on 127.0.0.1 before the dockable panel needs it.+///+/// HubClient.cs assumes something is already listening on the panel port — this+/// class is what makes that true on a machine where nobody has manually started+/// `aec-model-bridge-panel-server`. It never manages a hub it didn't start itself:+/// if something is already answering /health (a developer's own instance, or a+/// future bundled-runtime launcher), this leaves it alone entirely, both at+/// startup and at shutdown.+///+/// Python provisioning is not yet bundled with the installer (see+/// docs/product/DECISIONS_AND_RISKS.md D-010 — still open); this is a best-effort+/// launch matching the interpreter conventions docs/install.md already documents+/// (a project .venv, or a bare `python`/`py` on PATH), not a substitute for that+/// installer work.+/// </summary>+public sealed class PanelHubLauncher+{+ private const int HealthCheckTimeoutMs = 800;+ private const int PostLaunchPollIntervalMs = 500;+ private const int PostLaunchMaxAttempts = 10;++ private static readonly HttpClient HealthClient = new HttpClient { Timeout = TimeSpan.FromMilliseconds(HealthCheckTimeoutMs) };++ private Process? _launchedProcess;++ private static int Port+ {+ get+ {+ var raw = Environment.GetEnvironmentVariable("MCP_PANEL_HTTP_PORT");+ return int.TryParse(raw, out var port) ? port : 8787;+ }+ }++ /// <summary>+ /// Checks whether the panel hub is reachable and launches it in the background+ /// if not. Returns immediately; the check/launch/poll sequence runs on a+ /// background task so it never blocks Revit's OnStartup.+ /// </summary>+ public void EnsureRunning()+ {+ _ = Task.Run(EnsureRunningAsync);+ }++ private async Task EnsureRunningAsync()+ {+ if (await IsHealthyAsync().ConfigureAwait(false))+ {+ Log.Information("Panel hub already reachable on 127.0.0.1:{Port} — not launching a new one", Port);+ return;+ }++ var interpreter = ResolvePythonInterpreter();+ if (interpreter == null)+ {+ Log.Warning(+ "Panel hub is not reachable on 127.0.0.1:{Port} and no Python interpreter could be found to " ++ "launch it. Set AEC_MODEL_BRIDGE_PYTHON to a python.exe, or start it manually with " ++ "'aec-model-bridge-panel-server' / 'python -m revit_mcp_server.panel_server' — see docs/install.md. " ++ "The panel will show a connection error until the hub is reachable.",+ Port);+ return;+ }++ try+ {+ var startInfo = new ProcessStartInfo+ {+ FileName = interpreter,+ Arguments = "-m revit_mcp_server.panel_server",+ UseShellExecute = false,+ CreateNoWindow = true,+ RedirectStandardOutput = true,+ RedirectStandardError = true,+ };++ _launchedProcess = Process.Start(startInfo);+ Log.Information("Launched panel hub via '{Interpreter} -m revit_mcp_server.panel_server' (pid {Pid})",+ interpreter, _launchedProcess?.Id);+ }+ catch (Exception ex)+ {+ Log.Warning(ex, "Failed to launch the panel hub with interpreter '{Interpreter}'", interpreter);+ return;+ }++ for (var attempt = 0; attempt < PostLaunchMaxAttempts; attempt++)+ {+ await Task.Delay(PostLaunchPollIntervalMs).ConfigureAwait(false);+ if (await IsHealthyAsync().ConfigureAwait(false))+ {+ Log.Information("Panel hub is up on 127.0.0.1:{Port}", Port);+ return;+ }+ }++ Log.Warning(+ "Launched the panel hub but it never became reachable on 127.0.0.1:{Port} after {Attempts} attempts. " ++ "Check %LOCALAPPDATA%\\AECModelBridge or the process's own logs for why it failed to start.",+ Port, PostLaunchMaxAttempts);+ }++ private static async Task<bool> IsHealthyAsync()+ {+ try+ {+ using var response = await HealthClient.GetAsync($"http://127.0.0.1:{Port}/health").ConfigureAwait(false);+ return response.IsSuccessStatusCode;+ }+ catch+ {+ return false;+ }+ }++ /// <summary>+ /// Finds a Python interpreter capable of running revit_mcp_server, preferring+ /// an explicit override, then falling back to whatever's on PATH. Does not+ /// search for a project .venv, since the add-in has no reliable way to know+ /// where the hub's source checkout lives once installed — that's exactly the+ /// gap the bundled-runtime installer (D-010) is meant to close.+ /// </summary>+ private static string? ResolvePythonInterpreter()+ {+ var overridePath = Environment.GetEnvironmentVariable("AEC_MODEL_BRIDGE_PYTHON");+ if (!string.IsNullOrWhiteSpace(overridePath))+ {+ return overridePath;+ }++ foreach (var candidate in new[] { "python", "py" })+ {+ if (CanRun(candidate))+ {+ return candidate;+ }+ }++ return null;+ }++ private static bool CanRun(string command)+ {+ try+ {+ using var process = Process.Start(new ProcessStartInfo+ {+ FileName = command,+ Arguments = "--version",+ UseShellExecute = false,+ CreateNoWindow = true,+ RedirectStandardOutput = true,+ RedirectStandardError = true,+ });+ process?.WaitForExit(2000);+ return process is { HasExited: true, ExitCode: 0 };+ }+ catch+ {+ return false;+ }+ }++ /// <summary>+ /// Kills the hub process only if this launcher started it — a hub that was+ /// already running before Revit started (a developer's own instance) is left+ /// untouched, matching the same restraint EnsureRunning applies at startup.+ /// </summary>+ public void StopIfLaunched()+ {+ if (_launchedProcess == null)+ {+ return;+ }++ try+ {+ if (!_launchedProcess.HasExited)+ {+ _launchedProcess.Kill();+ Log.Information("Stopped the panel hub process this launcher started (pid {Pid})", _launchedProcess.Id);+ }+ }+ catch (Exception ex)+ {+ Log.Warning(ex, "Failed to stop the panel hub process cleanly");+ }+ finally+ {+ _launchedProcess.Dispose();+ _launchedProcess = null;+ }+ }+}