Skip to content

Open-source Revit MCP server: let Claude and other AI assistants read and edit BIM models, with human approval on every change.

feat(addin): add WebView2 dockable panel host (P16.1)

A. Sam Mohammade5154a6d6454
diff --git a/packages/revit-bridge-addin/RevitBridge.csproj b/packages/revit-bridge-addin/RevitBridge.csproj
index a9a8f6c..24b6e58 100644
--- a/packages/revit-bridge-addin/RevitBridge.csproj
+++ b/packages/revit-bridge-addin/RevitBridge.csproj
@@ -48,6 +48,7 @@
</ItemGroup>
<ItemGroup>
+ <PackageReference Include="Microsoft.Web.WebView2" Version="1.0.4078.44" />
<PackageReference Include="Serilog" Version="3.1.1" />
<PackageReference Include="Serilog.Sinks.File" Version="5.0.0" />
<PackageReference Include="System.Text.Json" Version="6.0.10" Condition="'$(TargetFramework)'=='net48'" />
diff --git a/packages/revit-bridge-addin/src/Bridge/AdditionalCommands.cs b/packages/revit-bridge-addin/src/Bridge/AdditionalCommands.cs
index 3ec146a..5c376d8 100644
--- a/packages/revit-bridge-addin/src/Bridge/AdditionalCommands.cs
+++ b/packages/revit-bridge-addin/src/Bridge/AdditionalCommands.cs
@@ -9,6 +9,22 @@ using MediaBrush = System.Windows.Media.SolidColorBrush;
namespace RevitBridge.Bridge
{
+ [Transaction(TransactionMode.Manual)]
+ public class CommandOpenPanel : IExternalCommand
+ {
+ public Result Execute(ExternalCommandData commandData, ref string message, ElementSet elements)
+ {
+ if (BridgePanelProvider.Show(commandData.Application, out var error))
+ {
+ return Result.Succeeded;
+ }
+
+ message = error;
+ TaskDialog.Show(ProductInfo.ProductName, "The AEC Model Bridge panel could not be opened.\n\n" + error);
+ return Result.Failed;
+ }
+ }
+
[Transaction(TransactionMode.Manual)]
public class CommandSettings : IExternalCommand
{
diff --git a/packages/revit-bridge-addin/src/Bridge/App.cs b/packages/revit-bridge-addin/src/Bridge/App.cs
index 2c52c13..66cdd7d 100644
--- a/packages/revit-bridge-addin/src/Bridge/App.cs
+++ b/packages/revit-bridge-addin/src/Bridge/App.cs
@@ -34,6 +34,15 @@ namespace RevitBridge.Bridge
Server = _server; // Expose statically
_server.Start();
+ try
+ {
+ BridgePanelProvider.Register(application);
+ }
+ catch (Exception ex)
+ {
+ Log.Error(ex, "Bridge started, but the AEC Model Bridge dockable pane could not be registered");
+ }
+
try
{
CreateModernRibbonInterface(application);
@@ -173,6 +182,18 @@ namespace RevitBridge.Bridge
// === TOOLS PANEL ===
+ // Open Panel Button
+ PushButtonData panelBtnData = new PushButtonData(
+ "cmdOpenPanel",
+ "Open Panel",
+ assemblyPath,
+ "RevitBridge.Bridge.CommandOpenPanel"
+ );
+ panelBtnData.ToolTip = "Open the AEC Model Bridge panel";
+ panelBtnData.LongDescription = "Shows the dockable AEC Model Bridge panel inside Revit.";
+ panelBtnData.Image = brandIcon16;
+ panelBtnData.LargeImage = brandIcon32;
+
// Settings Button (future)
PushButtonData settingsBtnData = new PushButtonData(
"cmdSettings",
@@ -210,6 +231,8 @@ namespace RevitBridge.Bridge
aboutBtnData.Image = brandIcon16;
aboutBtnData.LargeImage = brandIcon32;
+ toolsPanel.AddItem(panelBtnData);
+ toolsPanel.AddSeparator();
toolsPanel.AddItem(settingsBtnData);
toolsPanel.AddItem(helpBtnData);
toolsPanel.AddSeparator();
diff --git a/packages/revit-bridge-addin/src/UI/BridgePanel.xaml b/packages/revit-bridge-addin/src/UI/BridgePanel.xaml
new file mode 100644
index 0000000..85dc102
--- /dev/null
+++ b/packages/revit-bridge-addin/src/UI/BridgePanel.xaml
@@ -0,0 +1,32 @@
+<UserControl x:Class="RevitBridge.UI.BridgePanel"
+ xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation"
+ xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml"
+ xmlns:wv2="clr-namespace:Microsoft.Web.WebView2.Wpf;assembly=Microsoft.Web.WebView2.Wpf"
+ MinWidth="360"
+ MinHeight="420"
+ UseLayoutRounding="True"
+ SnapsToDevicePixels="True"
+ FontFamily="Segoe UI">
+ <Grid Background="#F8FAFC">
+ <wv2:WebView2 x:Name="Browser" />
+
+ <Border x:Name="Fallback"
+ Visibility="Collapsed"
+ Background="#F8FAFC"
+ Padding="20">
+ <StackPanel VerticalAlignment="Center">
+ <TextBlock Text="AEC Model Bridge"
+ FontSize="18"
+ FontWeight="SemiBold"
+ Foreground="#1F2937"
+ Margin="0,0,0,8" />
+ <TextBlock x:Name="FallbackMessage"
+ Text="Panel runtime unavailable."
+ FontSize="13"
+ LineHeight="20"
+ TextWrapping="Wrap"
+ Foreground="#4B5563" />
+ </StackPanel>
+ </Border>
+ </Grid>
+</UserControl>
diff --git a/packages/revit-bridge-addin/src/UI/BridgePanel.xaml.cs b/packages/revit-bridge-addin/src/UI/BridgePanel.xaml.cs
new file mode 100644
index 0000000..b8eb7ca
--- /dev/null
+++ b/packages/revit-bridge-addin/src/UI/BridgePanel.xaml.cs
@@ -0,0 +1,130 @@
+using System;
+using System.Text.Json;
+using System.Threading.Tasks;
+using System.Windows;
+using System.Windows.Controls;
+using Microsoft.Web.WebView2.Core;
+using RevitBridge.Bridge;
+using Serilog;
+
+namespace RevitBridge.UI
+{
+ public partial class BridgePanel : UserControl
+ {
+ private bool _initialized;
+
+ public BridgePanel()
+ {
+ InitializeComponent();
+ Loaded += async (_, _) => await InitializeWebViewAsync();
+ }
+
+ private async Task InitializeWebViewAsync()
+ {
+ if (_initialized)
+ {
+ return;
+ }
+
+ _initialized = true;
+
+ try
+ {
+ await Browser.EnsureCoreWebView2Async();
+ Browser.CoreWebView2.WebMessageReceived += OnWebMessageReceived;
+ Browser.NavigateToString(BuildShellHtml());
+ }
+ catch (Exception ex)
+ {
+ Log.Warning(ex, "WebView2 panel runtime is unavailable");
+ Browser.Visibility = Visibility.Collapsed;
+ Fallback.Visibility = Visibility.Visible;
+ FallbackMessage.Text = "WebView2 runtime is unavailable. Install Microsoft Edge WebView2 Runtime and restart Revit.";
+ }
+ }
+
+ private void OnWebMessageReceived(object? sender, CoreWebView2WebMessageReceivedEventArgs args)
+ {
+ string message;
+ try
+ {
+ message = args.TryGetWebMessageAsString();
+ }
+ catch
+ {
+ message = args.WebMessageAsJson;
+ }
+
+ Log.Information("Bridge panel message received: {Message}", message);
+ PostHostStatus();
+ }
+
+ private void PostHostStatus()
+ {
+ var payload = JsonSerializer.Serialize(new
+ {
+ type = "host.status",
+ serverRunning = App.Server?.IsRunning == true,
+ port = App.Server?.Port,
+ revitVersion = App.RevitVersion,
+ activeDocument = App.ActiveDocumentName
+ });
+
+ Browser.CoreWebView2?.PostWebMessageAsJson(payload);
+ }
+
+ private static string BuildShellHtml()
+ {
+ return @"
+<!doctype html>
+<html lang=""en"">
+<head>
+ <meta charset=""utf-8"">
+ <meta name=""viewport"" content=""width=device-width, initial-scale=1"">
+ <style>
+ :root { color-scheme: light dark; font-family: Segoe UI, system-ui, sans-serif; }
+ body { margin: 0; min-height: 100vh; background: #f8fafc; color: #1f2937; }
+ main { box-sizing: border-box; min-height: 100vh; padding: 18px; display: grid; gap: 14px; align-content: start; }
+ header { border-bottom: 1px solid #d1d5db; padding-bottom: 12px; }
+ h1 { margin: 0; font-size: 18px; line-height: 1.25; font-weight: 650; }
+ p { margin: 6px 0 0; color: #4b5563; font-size: 12px; line-height: 1.5; }
+ button { width: max-content; border: 0; border-radius: 6px; background: #2563eb; color: white; font: inherit; font-size: 13px; padding: 8px 12px; cursor: pointer; }
+ button:hover { background: #1d4ed8; }
+ pre { margin: 0; white-space: pre-wrap; word-break: break-word; border: 1px solid #d1d5db; border-radius: 6px; padding: 10px; background: white; color: #111827; font-size: 12px; }
+ @media (prefers-color-scheme: dark) {
+ body { background: #202124; color: #f3f4f6; }
+ header { border-color: #3f3f46; }
+ p { color: #cbd5e1; }
+ pre { background: #111827; border-color: #374151; color: #e5e7eb; }
+ }
+ </style>
+</head>
+<body>
+ <main>
+ <header>
+ <h1>AEC Model Bridge</h1>
+ <p id=""state"">Panel host connected.</p>
+ </header>
+ <button id=""ping"" type=""button"">Refresh Host Status</button>
+ <pre id=""status"">Waiting for host status...</pre>
+ </main>
+ <script>
+ const statusEl = document.getElementById('status');
+ const stateEl = document.getElementById('state');
+ function post(message) {
+ if (window.chrome && window.chrome.webview) {
+ window.chrome.webview.postMessage(message);
+ }
+ }
+ document.getElementById('ping').addEventListener('click', () => post('status.request'));
+ window.chrome.webview.addEventListener('message', event => {
+ stateEl.textContent = 'Host bridge active.';
+ statusEl.textContent = JSON.stringify(event.data, null, 2);
+ });
+ post('panel.loaded');
+ </script>
+</body>
+</html>";
+ }
+ }
+}
diff --git a/packages/revit-bridge-addin/src/UI/BridgePanelProvider.cs b/packages/revit-bridge-addin/src/UI/BridgePanelProvider.cs
new file mode 100644
index 0000000..7848165
--- /dev/null
+++ b/packages/revit-bridge-addin/src/UI/BridgePanelProvider.cs
@@ -0,0 +1,43 @@
+using System;
+using Autodesk.Revit.UI;
+using Serilog;
+
+namespace RevitBridge.UI
+{
+ public class BridgePanelProvider : IDockablePaneProvider
+ {
+ public static readonly DockablePaneId PaneId = new DockablePaneId(
+ new Guid("4E6D3F28-1C74-4B41-9B6E-7B1D3A2C0C4F"));
+
+ public static void Register(UIControlledApplication application)
+ {
+ application.RegisterDockablePane(PaneId, "AEC Model Bridge", new BridgePanelProvider());
+ Log.Information("AEC Model Bridge dockable pane registered");
+ }
+
+ public static bool Show(UIApplication application, out string error)
+ {
+ try
+ {
+ application.GetDockablePane(PaneId).Show();
+ error = "";
+ return true;
+ }
+ catch (Exception ex)
+ {
+ error = ex.Message;
+ Log.Warning(ex, "Failed to show AEC Model Bridge dockable pane");
+ return false;
+ }
+ }
+
+ public void SetupDockablePane(DockablePaneProviderData data)
+ {
+ data.FrameworkElement = new BridgePanel();
+ data.InitialState = new DockablePaneState
+ {
+ DockPosition = DockPosition.Right
+ };
+ }
+ }
+}