Next Gen STEP AP242 Native-ish BREP Geometric Modeling Kernel
CIR-BREP-X3 — FrictionLab canonical box-cylinder recognition experiments
Scope
Lab-only experiments in Aetheris.Firmament.FrictionLab/CIRLab and Aetheris.FrictionLab.Tests/CIRLab.
1) Exact CIR shape
- Hypothesis: recognize
SdfSubtractNode(SdfBoxNode, SdfCylinderNode)with optional pure translations. - Experiments: direct node + translated wrappers tests.
- Evidence: direct and translated cases pass; non-subtract rejected.
- Conclusion: first production recognizer should require subtract(box,cylinder) after optional translation-unwrapping.
- Recommendation: accept only identity/pure-translation wrappers in v1.
- Confidence: High.
2) Box/Cylinder coordinate conventions
- Experiments: bounds/evaluate assertions.
- Evidence: box centered at origin with half extents; cylinder centered at origin, Z-axis, half-height in ±Z.
- Conclusion: CIR primitive conventions are origin-centered signed-distance primitives.
- Recommendation: normalize around these conventions, then apply extracted translations.
- Confidence: High.
3) Through-hole requirement
- Experiments: short cylinder rejection, spanning cylinder acceptance.
- Evidence: height/depth and end-cap coverage checks separate through vs blind.
- Conclusion: v1 should require full through depth with tolerance band.
- Recommendation: reject blind/partial/miss.
- Confidence: High.
4) Allowed axes
- Evidence:
SdfCylinderNodeencodes only canonical Z axis; no intrinsic arbitrary-axis field. - Conclusion: axis variation must come from transforms.
- Recommendation: v1 supports only native Z-axis cases (plus translation).
- Confidence: High.
5) Transforms
- Experiments: pure translation vs rotation wrappers.
- Evidence: translation unwrap is safe; rotation wrapper rejected.
- Conclusion: detect pure translation by transformed basis vectors.
- Recommendation: reject rotation/nonuniform/shear in v1 with explicit reason.
- Confidence: High.
6) Firmament lowering shape for boolean_box_cylinder_hole
- Evidence (source inspection): lowerer always emits primitive local-frame + placement via
SdfTransformNode, then booleanSdfSubtractNode. - Conclusion: real path is frequently subtract of transformed operands, not always literal raw primitives.
- Recommendation: recognizer should include wrapper normalization.
- Confidence: Medium-High.
7) Recognition entrypoint
- Evidence: CIR node tree has enough for canonical v1 (shape + transforms + dimensions).
- Conclusion: node-first recognizer is sufficient for first scope.
- Recommendation: implement node recognizer first; add plan/replay adapter only if needed.
- Confidence: Medium.
8) What counts as box
- Evidence: accepted only
SdfBoxNode; non-box lhs rejected in tests. - Recommendation: strict
SdfBoxNodefor v1. - Confidence: High.
9) What counts as cylinder
- Evidence: accepted only
SdfCylinderNode; sphere tool rejected. - Recommendation: strict finite circular
SdfCylinderNodeonly. - Confidence: High.
10) Hole position constraints
- Experiments: centered, offset-valid, tangent, outside.
- Evidence: strict interior clearance inequalities reject tangent/grazing/outside.
- Recommendation: allow offsets when strict clearance holds; do not force centered-only.
- Confidence: High.
11) Tolerances
- Evidence: experiments use
ToleranceContext.Default.Linearfrom kernel numerics. - Recommendation: use shared tolerance context; classify near-boundary as tangent/unsupported conservatively.
- Confidence: High.
12) Recognizer return shape
- Evidence: lab result record carries success/reason/diagnostic, normalized primitives+translations, axis, through-length.
- Recommendation: production result should be structured, not bool.
- Confidence: High.
13) Recognition vs builder coupling
- Evidence: lab recognizes and returns normalized parameters without building BRep.
- Conclusion: separation is practical.
- Recommendation: recognizer returns normalized params; builder consumes them.
- Confidence: High.
14) Unsupported variants behavior
- Evidence: unsupported test matrix exercises stable reason codes.
- Recommendation: no fallback/guess; return explicit unsupported reason vocabulary.
- Confidence: High.
15) Production test needs
- Recommendation matrix:
- success: direct subtract, translated subtract
- rejects: non-subtract, lhs non-box, rhs non-cylinder, unsupported transform, blind/not-through, tangent/outside
- tolerances: near-boundary around clearance threshold
- Confidence: High.
Recommended production recognizer policy
Recognize only canonical subtract(box,cylinder) after unwrapping identity/pure-translation transforms; require positive dimensions, Z-axis cylinder convention, strict through-hole depth coverage, and strict XY interior clearance with shared tolerance.
Recommended production recognizer result shape
Success, ReasonCode, Diagnostic, normalized Box dimensions, normalized Cylinder radius/height, BoxTranslation, CylinderTranslation, Axis, ThroughLength, optional source-node references.
Recommended production test matrix
Copy/adapt all CIRLab tests under Aetheris.FrictionLab.Tests/CIRLab into production recognizer suite once production implementation starts.
Known deferred cases
- Rotated cylinders/boxes.
- Nonuniform-scaled/sheared transforms.
- Lowering-plan/native replay metadata adapters.
- Multi-hole/composite boolean chains.