Skip to content

Next Gen STEP AP242 Native-ish BREP Geometric Modeling Kernel

1008 B
Raw Blame

M4 DFM summary

New/strengthened rules:

  • exact analytic blank must exist and pass contour validation;
  • exact rectangular/round relief topology must exist;
  • relief width >= thickness;
  • relief depth >= inside radius + thickness;
  • minimum tangent-to-edge flange length;
  • existing inside-radius ratio, cut-to-bend, cut-to-edge, overlap, duplicate-cut, bend-line containment, and zero-width checks remain active.

Suggestions are structured and numeric (increase relief depth to 2.7 mm, increase flange Height/Length by X) and are never auto-applied. Findings use semantic subjects such as corner-Front-Right, FrontWall, and relief-Front-Right.

Template output uses normal SheetMetalDfm.Evaluate; no template duplicates DFM logic. The deliberate bad/fixed tray pair demonstrates semantic-only repair. The PSU enclosure passes. The four-relief M3 tray and CTC-03 fail the strict exact-blank rule, correctly preventing M4 from presenting compatibility boundaries as fabrication authority.