CTC-03 formed and flat comparison after Profile-M2 edge composition

Command:

aetheris sheetmetal compare testdata/step242/nist/CTC/nist_ctc_03_asme1_ap242-e2.stp docs/development/milestones/modules/sheetmetal/artifacts/m8/ctc03-final.firmament --json

Formed

Overall status is NeedsReview.

Measure Result
Thickness residual 0.0025400000 mm
Source → intent RMS / p95 / max 10.6140 / 19.0713 / 52.8161 mm
Intent → source RMS / p95 / max 6.75046 / 8.31005 / 19.0713 mm
Bend matches 7/7 Pass
Opening matches 17/17 Pass

Bend axis residual is at most 0.002542 mm; bend-axis angle residual is zero; bend-angle and radius residuals are numerical noise; all adjacency checks pass. Profile-M2 reconstructs the front and rear mounting-flange free-edge programs as semantic SteppedNotch fragments. Against the M8/Profile-M1 baseline, source-to-intent RMS fell from 19.4627 to 10.6140 mm and p95 from 52.4846 to 19.0713 mm. Remaining maximum error is localized to wall-end/corner topology.

Flat

Measure Result
Generated bounds 404.751790441 x 612.597760706 mm
Width residual 0.00244728 mm
Height residual 0.00781965 mm
Outer-contour RMS / p95 / max 12.0385 / 19.0475 / 19.0475 mm
Inner cuts 17/17 Pass
Bend-line count delta 0
Overlap none
Generated exact contour Valid
Source comparison status Fail

The generated blank is internally valid, connected, non-self-intersecting, and exact on the authored model. Mounting-flange reconstruction removes essentially all height error (12.7078 to 0.00782 mm). It is not yet tolerance-equivalent because the remaining wall corner/end transitions require cross-edge corner ownership rather than a baseline-returning single-edge fragment.

Independent regeneration and reimport

The final source reads no STEP path or recovered topology identifiers. Tests copy it into an isolated temporary directory before compilation. Generated formed and flat STEP files reimport as enclosed manifold bodies:

Artifact Bodies / shells Faces Edges Vertices Supports
Formed 1 / 1 113 260 166 84 plane, 29 cylinder
Flat 1 / 1 112 330 220 82 plane, 30 cylinder

DFM is Pass. Restoring the semantic mounting-flange outlines raises the two front mounting-hole edge clearances from the simplified 0.7849 mm result to 5.2324 mm without moving the source-matched holes.