Drawing definition and PDF reconstruction qualification

Engineering review and replacement acceptance gate

The earlier drawing integration preserved diameter PMI and produced readable vectors, but its example did not define hole locations or a controlling thickness. Approximate REF envelopes did not specify stock acceptance. Zero annotation collisions and successful export were insufficient acceptance tests. The original integration report is retained with a superseding review note.

The replacement gate asks whether a reader can reconstruct the nominal part from the PDF alone, then distinguishes specified limits from actual process capability and engineering approval. A 3D nominal model is not evidence of manufacturing capability. No source geometry was changed for this correction.

Ownership and implementation

BrepRectangularPlateQuery is a read-only kernel query. It admits six stock planes with exact rectangular boundaries and separated, inward-oriented circular Z-through-hole walls. Every face, outer loop, opening, seam and edge count is accounted for. Bound straight curves agree with their vertices; full circle trims and axis directions are checked. Imported shell orientation must be qualified. No sampled display bounds, source-name heuristic, history reconstruction or new geometry operation establishes completeness.

The drawing dimension planner consumes those facts and associated PMI. It emits controlling stock/thickness dimensions, an entry-face coordinate schedule from finished edges, hole IDs/center marks and grouped size/limit/THRU callouts. Source PMI identities survive grouping. An associated plane datum is shown in a useful view, rather than attached ambiguously to a plan-view corner. The side view uses qualified internal cylinder silhouettes as dashed lines, excluding parameter seams from the exterior outline.

Both generation modes share numeric, kind and face-association PMI admission. The default path does not execute the old overlay planner first. Reference-only views remain an explicit visualization mode marked incomplete/not for manufacture. Unhandled geometry or additional PMI families reject the default complete-plan path; there is no implicit success fallback. Source Drawing declarations still delegate to their authored owner and have no automatic completeness assessment.

PDF/SVG/PPTX/React project shared IR. The title/signoff table is retained, and hole schedules are native editable tables. Notes, tables, dimensions, labels and leaders participate in layout keepouts/audits. Long table values and impossible allocations reject instead of truncating data. Round-trip numeric text avoids rounding small tolerances to zero.

Requirements and bounded tolerance screen

The demonstration supplies explicit drawing inputs: 6061-T6 aluminium, bilateral stock/coordinate tolerance 0.1 mm and general angular tolerance 0.5 degrees. These are example authoring choices, not inferred source facts. The original diameter requirement remains 4 +0.05/-0.02 mm (3.98-4.05 mm); it is not advertised as a clearance fit for a 4 mm shaft. AP242 body geometry and original PMI are not rewritten with the additional drawing inputs.

The compiler records nominal completeness, specified dimensional tolerances, material, missing requirements and process capability separately. Missing linear, angular, material or hole-size requirements stay visible. Checked/Approved names and dates remain blank. The source-record and CLI signoff paths remain compatible.

The arithmetic screen checks positive stock/diameter intervals and hole web limits for independent Cartesian entry-center limits and cylinder-axis lean on ideal orthogonal planar stock. Projected bore radius accounts for lean. Its assumptions are explicit in IR. It does not qualify stock form, general angular stacks, surface finish, a functional fit, measurement uncertainty or machining capability. Diameter/depth/quantity contradictions and zero-width diameter limits reject.

For the example's 4 mm bore through 8 mm stock, a finishing/inspection operation would need to be selected and qualified. The 0.07 mm size band is not a guarantee for ordinary drilling. The Protolabs material/process capability table distinguishes ordinary holes from specified bore tolerances. That is feasibility context, not evidence that this part has been made or inspected. Functional fit and release remain engineering decisions; processCapabilityVerified is false.

Independent PDF reconstruction witness

fixtures/Regression/DrawingGeneration/reconstruct_from_pdf.py receives only a PDF, output directory and optional CLI executable. It reads visible dimension text and coordinate/type tables, then writes and compiles a fresh Firmament part. It does not access the original source, Drawing IR or embedded attachments. The reader convention is bounded to the documented dimensioned plate layout; it is not general-purpose drawing OCR.

qualify_pdf_roundtrip.py freezes that independent reconstruction before reading the reference STEP. It then uses the real CLI to compare topology, normalized bounds, surface families and volume. A verification-only adapter independently reads canonical STEP cylinder placements/radii, checking every hole's center and size, so misplaced holes cannot pass merely by preserving volume and counts. Global rigid placement is irrelevant to the local part definition.

Qualification runs the original ten-hole plate and a non-grid variant with one center changed to (-34.125, -17.25) mm. Four incomplete PDF text variants must be rejected: absent stock size, absent coordinate row, missing extent, and missing coordinate tolerance. No fixture expectations or original part dimensions are hard-coded into the independent reader.

python fixtures/Regression/DrawingGeneration/qualify_pdf_roundtrip.py --pdf artifacts/local/drawing-definition/final/InspectionPlateDrawing.pdf --reference-step artifacts/local/drawing-definition/final/InspectionPlate.step --out-dir artifacts/local/drawing-definition/roundtrip --cli Aetheris.CLI/bin/Release/net10.0/aetheris.exe

Qualification results

Raw evidence belongs in ignored artifacts/local/drawing-definition/; the independent readers are durable fixture support. Public usage and boundaries are maintained in docs/public/drawings.md.

Gate Result
Full solution Release build build-full.log: zero errors, 30 pre-existing warning occurrences
Focused Firmament drawings focused-final.log: 49 passed, including Open XML validation
Focused CLI drawings cli-final.log: 7 passed
Core fast lane fast-final.log: 1,087 passed
Complete solution regression full-final.log: 5,660 passed, zero failures/skips; FrictionLab reports no discovered tests
Client TypeScript / complete Vitest Typecheck passed; 19 files / 91 tests passed
Existing FrontendX4 corpus corpus-final.log: 32/32 passed; no baseline recording
Independent reconstruction Original and non-grid PDF-only reconstructions compile and match all cylinder axes/radii, topology, bounds and reported volume
Missing-data mutation checks All four rejected for each of the two PDFs
Geometry preservation Original 414 STEP geometric entities byte-identical to pre-refactor baseline; SHA256 c7ec5a43100cdf5368016315bbd02bbca59c82855f68cb50737f8845a73efe9c
Part / STEP presentation parity PDF, SVG and PPTX bytes identical
Final visual inspection Original and non-grid variants each fit one A4 landscape page; both PDFs rendered and inspected
Layout evidence Zero text/model, text/text or text/stroke collisions and zero failed annotations for both examples

git diff --check passes. The solution lanes ran serially with MSBUILDDISABLENODEREUSE=1, DOTNET_PROCESSOR_COUNT=2, -m:1, -nr:false, UseSharedCompilation=false and the prescribed full solution test command. At closeout no dotnet, testhost, MSBuild, VBCSCompiler or aetheris runtime hosts remain. Skill frontmatter/UI metadata validation also passes.

The CLI mass-property volume is explicitly NumericalWithBound with a triangulated boundary integral, not an authoritative exact volume assertion. Its agreement is a parity check. Independent analytic volumes from the printed stock/hole recipe and reference primitive parameters are also compared; the plate's analytic nominal volume is approximately 54,994.6903508513 mm3. This drawing pass does not change the verification engine's numerical integration policy.

Final example files are under final/InspectionPlateDrawing.*. The frozen reconstructions, PDF-only extracted definitions and comparison evidence are under roundtrip/ and asymmetric-roundtrip/. No original geometry expectations or source part fixtures were rewritten. PowerPoint desktop rendering/editing was not tested; native package validity, PDF rendering and shared presentation data were checked.

The focused gate includes successful geometry/coordinate coverage and native PPTX validation, perturbed non-grid centers, unsupported sphere/blind geometry, missing requirements, invalid tolerances, edge breakout, contradictory diameter/depth/ quantity, reference-only admission and preservation of previous drawing behavior.

Remaining limits and code-quality review

The complete-plan family is rectangular stock with disjoint Z-through holes. Other outlines, blends, blind/counterbored/countersunk holes, oblique holes, sections and automatic Assembly planning require their own qualified production owners. The current layout supports four distinct hole size/limit groups and paginates coordinate schedules after twelve rows; dense labels can reject. These are named stops, not evidence that an incomplete drawing defines a part.

This pass introduces no DSL parser, rewrite, diagnostic allowlist, geometry solver or UI-side dimension inference. Kernel queries own geometric facts; the drawing planner owns coverage/presentation; backends consume shared data. Authored drawing and old reference-view tests remain, with changed automatic expectations reflecting the new one-sheet complete definition rather than duplicate diameter sheets.

A reusable mechanical-drawing-review skill was created and validated in the user's Codex skill directory. It requires reconstruction from the exported artifact, function-driven limits, process/inspection distinction and truthful signoff. It supports review rather than becoming a parallel compiler validator. Layout choices follow MIT's completeness/nonredundancy guidance.

Verdict

Success for the qualified plate/through-hole family. The corrected one-page PDF contains enough visible information to reconstruct the nominal part, with explicit dimensional requirements and material rather than inferred defaults. An independent PDF-only reader reconstructs both the original and irregular variants, and geometry comparisons pass. The source body's exact geometry is unchanged; unsupported automatic families stop explicitly.

This is not a general manufacturing-release or process-capability certification. Qualified shop execution, stock form/finish, functional fit, inspection uncertainty and engineering signoff remain distinct from the successful drawing-definition gate. The implementation and public documentation preserve that distinction.

Coordinate zero and table limits follow-up (2026-10-19)

The review correctly identified that naming reference edges in a note did not make their zeros immediately visible, and burying coordinate limits in general notes made the hole schedule harder to use. The shared dimension planner now projects X0 and Y0 leaders onto the exact left/bottom finished stock planes and marks their intersection (0,0) on the top face. These are drawing coordinate references; source datum A and AP242 PMI remain unchanged.

Both table headers carry explicit independent bilateral limits (X ±0.1, Y ±0.1 mm for the example). These define Cartesian entry-center intervals, not a circular GD&T position zone. --linear-tolerance remains the explicit authoring input; unspecified limits print TOL?. Header widths are checked alongside row values. Notes were shortened to retain missing-requirement warnings within the reserved area, including the case where diameter limits are absent too.

Evidence is under artifacts/local/drawing-coordinate-datums/. Fifty focused drawing tests and seven CLI drawing tests pass. Coverage checks both zero leaders and the origin against the projected stock, the existing datum A, missing limits, and a nondefault ±0.025 mm input without changing nominal coordinates. Both PDFs were rendered and visually inspected; the regular and asymmetric variants have zero text/model, text/text or text/stroke collisions. Native PPTX validation passes.

The independent PDF reader now obtains each axis limit from its table header and requires the zero labels in the view region separately from the explanatory notes. Eight missing-data mutations reject for each PDF, including each zero reference, the origin and each axis tolerance. Both frozen PDF-only reconstructions compile and match the reference topology, bounds, exact cylinder centers/radii and analytic volume. PDF/SVG/PPTX bytes match between part and STEP input. Original STEP content through the geometric entities is byte-identical to the pre-refactor baseline.

The follow-up full solution regression passes 5,661 tests across 20 test assemblies, with zero failures/skips; FrictionLab still discovers no tests. The prescribed Core fast lane passes 1,087 tests. Logs are full.log and fast.log in the follow-up evidence directory. The final build completes with zero errors.

FrontendX4 passes 32/32 (corpus.log), without recording new geometry baselines. The final code-quality pass confirms that the references, limits and provenance belong to the existing shared dimension planner; no renderer-specific inference, new drawing schema or body modification was introduced. git diff --check passes, and no dotnet, testhost, aetheris, MSBuild or VBCSCompiler hosts remain at closeout. This follow-up is Success for the requested coordinate-reference refinement; manufacturing approval and process capability remain unqualified.