PMI showcase: dogfooding PMI on a real machined part

Goal. Specify a composed machined part (boss, pockets, bore, counterbored holes, chamfer) completely enough to make it without a drawing, and present it as an annotated GLB. Use the attempt to find out whether the PMI system is usable, not just technically present.

Part. fixtures/Canonical/PMI/showcase-bearing-mount.firmament, built by demos/Aetheris.PmiShowcase into STEP AP242 and GLB. 28 semantic records: 3 datums, 17 sizes and locations, 5 geometric controls, 3 notes.

What blocked a complete specification, and what changed

Found Change
dimension: never bound on Compose bodies (Statics were not passed to the Compose PMI binder) Bound Statics flow to every mechanical construction route
No way to target a boss top or pocket floor; face(+Z) is ambiguous on a stepped part face(op.Top), face(op.Bottom), face(pocket.Floor)
Datums on faces split by construction exported unattached, silently Axis faces resolve to the extreme support plane (all coplanar pieces); an authored datum with no face rejects
No quantity: one hole annotated, or four separate callouts Hole lists: one requirement with its quantity, on every shaft wall
Position on a counterbored hole also associated the counterbore wall Hole sizes and controls apply to the shaft only
No part notes (material, general tolerance) Note
Sizes written only in an Aetheris-private AP242 form Also written as standard DIMENSIONAL_SIZE/DIMENSIONAL_LOCATION + PLUS_MINUS_TOLERANCE; readers count once
No way to state block, boss, pocket, counterbore or chamfer sizes, or feature locations Dimension (construction parameters, values from the built body), Location, HoleCallout
face(h.Wall) rejected on Compose holes with a bare code Accepted (the shaft); PMI record errors are located at the record and explained
Hole-wall strips tessellated as 32×256 grids (chord tolerance read as a parameter step) Straight direction of a rectangular trim is one cell; the curved direction keeps its edge samples. GLB 95 MB → 2.6 MB

Presentation was rewritten: callouts grouped per feature and placed in annotation planes with collision avoidance (including in the default view's projection), Y14.5-shaped frames and datum symbols drawn as vectors, filled text on panels, B-rep edges over a translucent body, per-feature leader colours, sizes on their features, overall dimensions outside the part, baseline locations.

Evidence

  • Showcase readback: every record associated with faces; display draws all 28.
  • Standard form checked independently: with the native records renamed away, the foreign-PMI reader recovers each diameter, tolerance and location from the standard entities alone (PmiShowcaseTests.Sizes_AreAlsoWrittenInStandardAp242Form_AndReadOnce).
  • Full lane passes. Drawing generation accepts the standard entities that restate a native record (StandardMirrors on the inspection); it still rejects foreign ones.

Verdict

Meaningful progression toward success: the part is fully specified by its model and the GLB reads as an engineering presentation.

Stopped or deferred, with reasons

  • Rounded stock corners + boss + chamfer: works, after one gate change. Arc outlines route to the rim planner (the chimera route: exact plane and cone chamfer patches), which grafts the source-planned cavities back into the finished skin. It admitted only through round holes. The graft was already generic, so it now retains anything hanging off the stock caps' inner loops (boss, blind pockets, counterbores), provided every footprint clears the rim corridor and no retained face reaches the stock's side walls. The showcase keeps the sharp outline; the rounded variant is covered by PmiShowcaseTests.RoundedStock_RimChamferRetainsBossPocketsAndCounterbores. The section-stack route stays line-only (inset, variable-outer interval, emitter). Not projected: the stock corner radius as a Dimension.
  • Standard form for quantity lists. 2X pocket lengths, depths and the chamfer are written in the native form only; single-feature sizes and all locations are written in both. A list needs one standard dimension per feature.
  • Basic flag in AP242. basic: true is native and presentation-only; the standard qualifier for basic dimensions is not written yet.
  • Not projected yet: fillet radius, countersink callouts, locations between two features (only from an axis face).
  • Helios draws PMI from Lines; glyph outlines remain there, so it keeps showing text, but it does not yet use the filled text, panels or leader colours.