Next Gen STEP AP242 Native-ish BREP Geometric Modeling Kernel
Cadmata — browser-first Windows bundle
Download Aetheris-2.0.0-win-x64.zip from
Aetheris releases.
Extract the entire ZIP to a local folder. Open Aetheris-win-x64 and run
Cadmata.exe. It starts a local CAD session and opens your default browser.
It uses your existing browser; the normal ZIP contains no private Chromium,
Edge or WebView2 runtime. No WebView2 installation is needed for this mode.
.\Cadmata.exe
# Or open a part directly:
.\aetheris.exe view .\testdata\firmament\inline-step\canonical-through-hole.step
Cadmata opens a blank workspace. Use STEP 242 Viewer to open your own STEP file,
or generate a part in Product Gallery. Set Export filename before
generation; the part appears in the viewport and keeps that name for downloads.
Download Canonical 242 keeps the imported or generated product's filename;
browser downloads use the filename portion of an export path.
Close the server console window, or press Ctrl+C there, to end the session.
Closing only the browser tab does not stop the local server. Reopen Cadmata.exe
to start another session. Cadmata.exe --no-browser --urls http://127.0.0.1:5090
starts an explicitly addressed server without opening a browser.
Left-drag to orbit freely through the top and bottom orientations, right-drag or Shift-drag to pan, and scroll to zoom. Standard view selects exact top, bottom, front, back, left, right or isometric views. Refresh Display Data refreshes the currently loaded model and is disabled in an empty workspace.
The Modeling Demo builds one composed part from a rectangular base and a centered raised block. Set their dimensions in millimetres and select Build composed part. It uses the same Firmament Compose planning and STEP export as the compiler; it does not run the retired two-body Boolean demo. The raised block must fit within the base footprint. Expand Firmament source to inspect the program used to construct the part.
Windows 11 x64 is the initial qualification target. A WebGPU-capable GPU/driver is recommended. Three Telos uses automatic CIR where qualified and mesh otherwise. A browser without WebGPU uses the labeled existing WebGL fallback; initialization/device failures show a diagnostic. The ZIP includes the .NET runtimes and production UI assets. No SDK, Node or internet connection is needed for local CAD in an existing browser. Extract into a fresh local directory when updating, rather than merging old browser/runtime files into the new package.
Optional desktop window
Run Cadmata.Desktop.exe to use a dedicated Windows window instead of a browser tab. It uses the shared Microsoft Evergreen WebView2 Runtime. If that runtime is missing, it offers Microsoft's download page and a Retry button. Installation is explicit; Cadmata never downloads or installs a browser automatically. Normal Cadmata.exe does not need this prerequisite. Closing the optional desktop window stops its local server.
An explicitly packaged offline desktop edition may carry a webview2 directory.
Keep that directory intact and update that edition to receive browser fixes.
Fixed-runtime editions require a local ASCII extraction path; spaces work,
but a CJK path previously failed loading the runtime's dxil.dll. Network/UNC
locations are unsupported for that fixed runtime. These restrictions do not
describe the normal browser-first package.
The executable is unsigned. Windows may display an unknown-publisher warning for a downloaded ZIP. The portable application has no installer or automatic updater. Your browser and shared Evergreen runtime receive their own updates; download a newer ZIP to update Cadmata itself.
In the optional desktop window, About Cadmata shows the version and source identity. Open diagnostic log shows
the current session log. Logs and disposable browser profiles live under
%LOCALAPPDATA%\Aetheris\Cadmata; the extracted application is read-only during
normal use. Twenty diagnostic logs are retained. Exports use browser downloads,
and model state is session-local. Reopening starts a blank workspace. An explicit
STEP or Firmament file argument still opens that file at startup.
STEP import keeps its qualification status visible. Warnings and informational messages are summarized as counts; errors remain visible with their explanations. Use Download diagnostic log beside the summary to save all messages, including their severity, code and source. The same API diagnostics are recorded in the desktop session log, accessible through Open diagnostic log. This presentation does not change import tolerances, qualification or geometry.
Aetheris is AGPL-3.0-only; the managed Copeland compiler retains GPLv3.
See LICENSE and licenses/ for bundled dependency notices.
CORRESPONDING-SOURCE.md supplies exact source revisions and downloadable source
archives for both projects. Source: https://github.com/yuechen-li-dev/Aetheris.
BUILD-METADATA.json identifies the source revision, modifications, default browser
presentation and optional desktop runtime mode. Evergreen has no packaged browser pin.
A package marked modifiedSource is a local qualification candidate, not a
published source-identical release.