Humanoid X2 constrained kinematics research (historical)

Experimental. Humanoid work is research, not part of the supported product. Its APIs, syntax and results may change or be withdrawn. See experimental modules.

REST-X1 supersedes the relative-to-rest angle convention described below. Current RequestedHumanoidPose values are absolute anatomical states. See Semantic humanoid pose normalization.

Status: Meaningful progression, not an accepted humanoid. Antonia remains the X1 adoption candidate. The new solve admits hip, elbow and knee requests; it does not claim a complete anatomical domain or replace the historical quaternion research API. See the X2 release record.

Public API

The Aetheris.Humanoid project exposes:

using System.Text.Json;
using Aetheris.Humanoid;

var candidate = JsonSerializer.Deserialize<AntoniaAdoptionCandidate>(
    File.ReadAllText("artifacts/local/humanoid-x1/antonia-adoption-candidate.json"),
    HumanoidArtifactIO.JsonOptions)!;
var skeleton = candidate.PreparedSkeleton;
var surface = candidate.SourcePoseSurface with
{
    Vertices = candidate.SourcePoseSurface.Vertices.Select((v, i) =>
        v with { Position = candidate.PreparedPositions[i] }).ToArray()
};
const long shapeRevision = 0;
var request = new RequestedHumanoidPose(
    "hip-knee-90", skeleton.SkeletonId, skeleton.RestPoseId, shapeRevision,
    [new(HumanoidJointKind.LeftHip, FlexionDegrees: 90),
     new(HumanoidJointKind.LeftKnee, FlexionDegrees: 90)]);
var result = HumanoidKinematicSolver.Solve(skeleton, request, shapeRevision);
if (result.Pose is { } solved)
{
    // GlobalTransforms has the same order as skeleton.Joints.
    // Joints reports solved coordinates; Residuals exposes CenterMm and LinkLengthMm.
    var surfaceResult = HumanoidConstrainedSurface.Evaluate(surface, skeleton, shapeRevision, solved);
    // Positions remain available as diagnostic evidence when Evidence.IsAdmissible is false.
    // Do not present a failed surface as an accepted humanoid or production export.
}
// Inspect result.Diagnostics and result.Projections even when a solve succeeds.

AnatomicalSolvePolicy.Reject is the default. Pass policy: AnatomicalSolvePolicy.Project to request deterministic parameter projection. It is radial projection after component clipping, not a minimum geodesic-distance optimization. Rejected requests have no Pose.

RequestedHumanoidPose accepts semantic angles only; it cannot express joint translation, scale, arbitrary quaternion, or link-length edits. These are not disguised as zero-residual requests. Duplicate/unknown joints, nonfinite angles, stale skeleton/rest/revision identities, corrupt binds, invalid hierarchy and side mismatches fail closed. SolvedHumanoidPose has no public constructor or mutable exposed collections. Skin evaluation rejects a solved pose from another rest skeleton or shape revision.

For the local candidate, deserialize AntoniaAdoptionCandidate with HumanoidArtifactIO.JsonOptions, use PreparedSkeleton, and replace the positions in SourcePoseSurface.Vertices with PreparedPositions using with. Use revision 0. Do not load this candidate as CanonicalHumanoid or substitute the X0 synthetic fixture. This conversion changes positions only; connectivity and weights are retained.

Interfaces and pose invariants

HumanoidKinematicSolver.Interfaces(skeleton) returns typed AnatomicalHingeInterface and AnatomicalBallInterface definitions with participants, parent socket, axes/ranges. Links(skeleton) returns parent/child identities and rest lengths. They follow Aetheris' participant, constraint, residual and explicit rejection patterns. This progression does not register a new Firmament Concept<T> or Interface<T> compiler family.

Interface Admitted coordinates Projection and equation
Hip Flexion −20..120°, abduction −25..45°, twist ±45° at rest Normalized flexion/abduction squared sum ≤1; twist limit decreases to ±22.5° at swing boundary
Elbow Flexion 0..145° Hinge axis from rest forearm × forward; abduction and twist zero
Knee Flexion 0..140° Hinge axis opposite rest lower leg × forward; abduction and twist zero

The original X2 implementation used an exponential-map delta from the supplied rest. REST-X1 replaced that behavior with a direct solve from absolute flexion and abduction to the canonical bone direction. Positive hip flexion moves the leg forward; positive knee flexion moves the lower leg backward. Source elbow and knee bends are removed in their measured source plane before canonical flexion is applied.

These bounds are explicit engineering assumptions. The CDC reference study provides context for useful adult flexion ranges; the coupled domain and twist reduction above are not values validated by that study. No medical certification or complete human ROM coverage is claimed.

Every parent socket transformed by the parent's solved frame must coincide with the child origin within 0.001 mm. All parent-child distances must remain within 0.001 mm of rest length. Rest/bind consistency uses a 0.0001 matrix-component tolerance. Finite rigid transforms, acyclic ordered hierarchy, side consistency and current revision are checked before skinning. Input order is canonicalized by joint kind. Unsupported joints remain at rest when omitted; explicitly requesting one returns HUM209, even at zero.

Shoulder ball coordinates are now admitted for bounded REST-X1 comparison. They do not model clavicle/scapular coupling. Wrist, ankle, neck, spine and finger requests remain unsupported. Collision, self-contact, scapular motion, and a complete clinical biomechanics model remain unimplemented.

Surface screening and migration boundary

Order: validate rest and request → reject/project coordinates → compute rigid transforms → validate center/length residuals → LBS → inspect surface. HUM200 means a rejected range; HUM201/202 identify failed center/length residuals; HUM205 records projection; HUM208 identifies invalid/stale input; HUM209 identifies unsupported interfaces. Surface HUM206/207 diagnostics are independent of pose success.

The surface screen rejects nonfinite positions, triangles below 0.0001 mm², bidirectional edge ratio above 4, or a dominant-influence normal reversal. It reports unique edges per face region with nearest-rank median/p95/p99/max. An edge shared by different regions participates in each region's statistics. The 4× bound is a provisional catastrophe screen, not visual acceptance. The reversal count is a transported-normal proxy, not a certified inversion or self-intersection count. Self-intersection and volume are unavailable.

There are no admitted Antonia foot attachment frames, landmarks, morphs or measurements. The existing 88 landmarks/19 attachments belong to the X0 regression fixture. A solved ankle matrix is not a sole attachment frame. Morphing must rebuild binds and frames and increment the shape revision before solving again. Antonia morph qualification is still blocked.

HumanoidPosing remains the unconstrained historical evaluator needed for source-pose preparation and X0/X1 comparison. It can bypass X2 constraints; therefore the overall runtime replacement criterion is not met. Callers of the new constrained path must use HumanoidKinematicSolver followed by HumanoidConstrainedSurface, and preserve failure evidence.

Reproduce

dotnet run --project tools/Aetheris.Humanoid.X0 -- constrained-antonia --input artifacts/local/humanoid-x1/antonia-adoption-candidate.json --out-dir artifacts/local/humanoid-x2
dotnet test Aetheris.Humanoid.Tests/Aetheris.Humanoid.Tests.csproj

The candidate is produced by the existing X1 workflow. evidence.json is deterministic; timings.json is separate. Failed OBJ outputs include .failed-diagnostic in their filenames. Passing numeric screens do not constitute human visual signoff.

Render with Blender's background mode and scripts/render-humanoid-x2.py. Optional repeatable --fbx <local-file> arguments inspect supplied references without copying them into the repository. ASCII FBX receives a declaration inventory because the installed Blender importer rejects ASCII; no FBX posed deformation comparison is claimed in that case.