Next Gen STEP AP242 Native-ish BREP Geometric Modeling Kernel
Humanoid source-pose comparison
Experimental. Humanoid work is research, not part of the supported product. Its APIs, syntax and results may change or be withdrawn. See experimental modules.
HUMANOID-X4 adds a corresponding-index diagnostic path for the admitted Antonia topology. It does not add a deformation algorithm or retune Judgment.
Source lineage and current boundary
Antonia 1.2 was authored as a Poser figure. The pinned original OBJ supplies
the adopted geometry and the pinned Poser CR2 supplies declaration evidence
for joint centers, falloff spheres, bulge controls and joint-controlled morphs.
The later CharMorph char.blend is a Blender conversion/package, not the
original rig authority.
The current legal/admission record permits read-only local research inspection of the hash-pinned CharMorph Antonia inputs. It does not admit the conversion's Rigify generation, shared tweaks, weights, sliding-joint behavior, drivers or modifier stack as a canonical/runtime dependency. X4 therefore extracts neutral geometry and rest frames safely, but refuses to label an approximate Blender rig as an authored source pose evaluator.
Reproduce the available evidence
Prerequisites are the existing X1 adoption candidate and the pinned local CharMorph research inputs from HUMANOID-RECON-X0. Blender is launched with factory startup and auto-execution disabled.
powershell -ExecutionPolicy Bypass -File scripts/qualify-humanoid-x4.ps1 -SkipFullTests
The script:
- verifies pinned source hashes;
- extracts the neutral CharMorph mesh without executing bundled scripts;
- creates and hashes the explicit canonical-to-source vertex map;
- proves every admitted quad exists in the source mesh;
- extracts source metarig rest frames as data blocks;
- compares the neutral source positions through the real constrained and Judgment-driven Aetheris path;
- renders the measured hip centers/axes; and
- replays all deterministic JSON/OBJ evidence byte for byte.
Generated output is under artifacts/local/humanoid-x4/ and remains ignored.
Comparison command
Once a source pose dump has the X4 schema and a verified canonical mapping:
dotnet run --project tools/Aetheris.Humanoid.X0 -- compare-source-pose `
--input artifacts/local/humanoid-x1/antonia-adoption-candidate.json `
--source-pose artifacts/local/humanoid-x4/source-neutral.json `
--output artifacts/local/humanoid-x4/neutral-comparison.json
The command refuses topology or connectivity mismatches. It solves the declared left-hip request through current Aetheris kinematics, evaluates all current deformation candidates, records the Judgment result, and reports corresponding-vertex RMS/p50/p95/p99/max, signed mean displacement, regional metrics, edge ratios, orientation reversals, and the known X2/X3 hip-edge witness. It never performs pose-time nearest-surface matching.
Pose dump contract
A source pose dump records:
- canonical topology and connectivity IDs;
- the SHA-256 of the explicit neutral index map;
- the hash-pinned source asset and extractor versions;
- positions in canonical vertex order and millimeters;
- joint, side, angle, frame, convention, and rest basis; and
- limitations preventing a stronger interpretation.
The current extractor accepts only neutral. Non-neutral source dumps must not
be produced until the exact conversion/deformation stack is reviewed and the
pose control semantics are documented. A future posed extractor must retain
this topology/mapping contract and export all materially changed rig nodes.
Current semantic result
The Poser lThigh_jointx center is a deformation pivot. The CharMorph
metarig thigh.L head is a control-rig pivot / weighted-anchor candidate.
They are independently derived and land 1.8182 mm apart in the canonical
frame. The current Aetheris LeftHip bind origin is a socket proxy derived
from a mesh-group seam, not a proven anatomical joint center. It is 108.8132
mm from the Poser deformation pivot. Aetheris has no distinct femur-head frame.
Those concepts must remain explicit. Neither source rig pivot should be renamed into an anatomical hip center without anatomical evidence.