Next Gen STEP AP242 Native-ish BREP Geometric Modeling Kernel
Grooves and manual ribs
Use named Concept guides or Paths to locate a channel or reinforcing rib. The guide retains layout intent; the feature supplies its section and dimensions. Both features produce one integrated analytic body, rather than overlapping tool solids.
Manual rib
This complete example is manual-rib.firmament:
Model ManuallyRibbedPlate {
units: mm
Concept Struct Layout on XY {
Point2 Start { position: [-18mm, 0mm] }
Point2 End { position: [18mm, 0mm] }
Line2 Spine { from: Start; to: End }
}
Box Plate { size: [60mm, 40mm, 6mm] }
Modify Plate {
Rib<Rectangular> Stiffener {
on: face(Plate.Top)
path: Layout.Spine
thickness: 3mm
height: 10mm
draft: 2deg
ends: Round
}
}
}
Rib adds material to an existing host. It does not run AutoRib, relocate a guide,
or select a reinforcement network.
pathnames a line, circular arc, circle, or a Path resolving to one such segment. Guide coordinates are XY coordinates local to the support.thicknessis the full base thickness, centered on the guide.heightis measured outward from the support.draftdefaults to0deg. Positive draft narrows both sides toward the top: top thickness = base thickness − 2 × height × tan(draft).endsdefaults toFlat. Straight guides also admitRound, giving semicircular ends in plan. Flat end planes remain at the guide endpoints: side draft does not shorten the guide. Flat end faces therefore have zero end draft, even when the band sides have positive draft.- A closed circular guide has no ends; omit the field.
For a rounded straight rib, the guide endpoints are the centers of its rounded ends. Overall length is guide length plus thickness at the relevant height. An arc rib uses exact conical sides when drafted.
Rib junctions and mixed features
Separate named ribs may meet as T, L or X junctions. Their footprints are united into one material boundary; internal overlapping walls are removed. Zero-draft line, arc and circular ribs may have different heights. Drafted junctions currently require straight Flat-ended ribs of one common height. The compiler proves the boundary stays affine through every possible section event; topology-changing taper rejects rather than emitting an approximate loft.
The complete reinforced mounting plate
combines two crossing drafted ribs, counterbored and countersunk through holes,
and a top perimeter fillet. Top-entry ThroughAll holes and one +Z perimeter
Fillet or Chamfer reuse the ordinary stock feature builders. Rib and groove
footprints must clear the holes' largest entry diameter and the perimeter finish.
The holes do not require a perimeter finish. Noninteracting grooves may share the same stock. A hole crossing a rib, or a
groove crossing another path feature, is explicitly rejected.
Build JSON exposes ribPlanning: the selected construction, candidate admission
and utility, and checked section intervals. Existing isolated constructions are
preferred to preserve their geometry. A completely buried/redundant named rib
is rejected because no independent feature boundary survives. Feature order does
not change a junction network's generated geometry or semantic names.
Plate channels and circular face grooves
plate-channels.firmament
contains two separate straight channels. Inside Modify Plate, write:
Groove<Rectangular> Channel {
on: +Z
path: Upper
width: 4mm
depth: 2mm
ends: Round
}
Groove<Rectangular> removes a centered band of the specified width and depth.
Groove<Semicircular> takes radius instead: opening width is twice the radius
and depth equals the radius. Supplying independent width/depth to a semicircle
is rejected.
For Round-ended straight channels, guide endpoints are cap centers: the opening extends by half its width beyond each end.
A straight semicircular channel has a cylindrical bottom and, with Round ends, spherical end patches. A circular or arc channel has a toroidal bottom. plate-seal-groove.firmament demonstrates a circular face groove.
Cylindrical grooves
shaft-seal-groove.firmament declares a coaxial Circle2 with the shaft radius, then uses:
Modify Shaft {
Groove<Rectangular> SealSeat {
on: face(Shaft.OuterWall)
path: Layout.Seal
station: 20mm
width: 4mm
depth: 2mm
}
}
station is the axial center measured from the stock base (Z = 0). Width is
axial; depth is radial into material. OuterWall cuts inward, and InnerWall
cuts outward. The latter requires a top-open Cylinder<Hollow> host; its guide
circle radius equals the inner radius. See
bore-seal-groove.firmament.
Both rectangular and semicircular sections are supported. The cut must leave
positive wall and axial end margins.
These constructs define geometry. An O-ring gland's squeeze, fill, clearances, material compatibility and pressure suitability require separate engineering requirements; a groove is not an automatic seal-design approval.
Current limits
- Planar ribs/channels require a direct Box's top support (
+Z,Toporface(Body.Top)). Other faces, Extrude/Compose and imported-body hosts reject. - Cylindrical grooves require coaxial full circles on a direct Cylinder or
top-open
Cylinder<Hollow>, with no bottom blend. Cylindrical ribs, axial/helical cylinder channels and arbitrary surface paths reject. - Open arcs require Flat ends and a positive sweep of at most 180 degrees. Compound Paths and arbitrary sections reject; junctions use separate named ribs.
- Planar footprints must remain strictly inside the support. Rib networks use exact line/arc arrangements. Grooves remain separate; their interactions reject. Groove-only sets retain conservative disjoint XY envelope admission. Cylindrical groove axial envelopes must be disjoint.
- Box ribs/channels may combine with the bounded holes and perimeter finish described above. Perforation, Thread and mixed cylindrical-groove operations remain unsupported. No requested operation is silently dropped.
- A rib top may not collapse under draft; a groove must leave positive material. No base fillet, molding-release certification or automatic rib placement is implied. Existing PlasticShell AutoRib retains its separate qualified limits.
- Construction points and guides must have unique names, including across Concept Struct scopes. Non-XY construction frames are rejected for these support-local feature consumers.
- Feature names and source provenance are retained. This does not introduce
public selectors such as
face(Stiffener.Top). - Authoritative volume assertions and SDF measurement are not yet qualified for these composite bodies. The CLI reports that limitation; topology inspection and explicitly numerical mesh comparisons remain available.
Related: Profiles and construction, material offsets, PlasticShell, and solids and features.