Semantic piping and local autorouting

Aetheris piping separates connection intent from route geometry and hardens the equipment endpoint seam:

PipingSystem → equipment-owned Port + Nozzle → Connection
→ explicit Route or RouteRequest → RouteProposal → accepted Route
→ endpoint Mate + PipeSegments + fittings → Assembly → BOM/Cut List → AP242

The router is a design assistant. RouteProposal is inspectable; acceptance copies its ordered anchors into an ordinary RouteIr. The accepted route retains provenance but no solver ownership. Rebuilding an explicit or previously materialized route does not invoke pathfinding.

Ports and logical connections

Piping uses PascalCase constructs, camelCase fields and preserved catalogue/enum symbols. Historical PascalCase field aliases remain admitted through the same AST binder: connectionType: Weld and connectionType: Weld mean exactly the same thing. Unknown fields, duplicate aliases, nested foreign statements and unsupported placement clauses reject with source-located errors. Optional defaults apply only when a field is absent; malformed authored values never select the default.

Port is the piping specialization of an Assembly Interface. It has stable identity, a position/DatumFrame, an outward axis direction, a PipePolicy, and a bounded connection style.

PipePolicy Pipe25 {
    outerDiameter: 25mm;
    wallThickness: 2mm;
    material: "Standard.Materials.StainlessSteel.304_Annealed";
}
Port PumpDischarge {
    position: [100mm,100mm,250mm];
    direction: [1,0,0];
    pipePolicy: Pipe25;
    connectionType: Flange;
    equipment: Pump;
    nozzleLength: 50mm;
}
Connection Supply {
    from: PumpDischarge;
    to: CoolerInlet;
    pipePolicy: Pipe25;
    service: "CoolingSupply";
}

Connections exist before routes. Different port policies require reducer: true; different connection styles require adapter: true. Piping records those requirements but does not claim a standards database.

Direct PipePolicy declarations require all three fields: outerDiameter, wallThickness, and material; there are no implicit dimensional or material defaults. Both dimensions must be positive and twice the wall thickness must be less than the OD.

Equipment-owned nozzles and endpoint mates

X3a associates a port with one equipment proxy and materializes the gap between the equipment face and route endpoint as a hollow semantic nozzle occurrence:

KeepOut PumpBody {
    min: [0mm,0mm,0mm];
    max: [50mm,300mm,350mm];
    concept: EquipmentProxy;
}
Equipment Pump { keepOut: PumpBody; }
Port PumpDischarge {
    position: [100mm,100mm,250mm];
    direction: [1,0,0];
    pipePolicy: Pipe25;
    connectionType: Flange;
    equipment: Pump;
    nozzleLength: 50mm;
}

position is the pipe-side mating plane. The nozzle root is position - direction × nozzleLength and must lie exactly on the outward face of the equipment's KeepOut. The nozzle exposes EquipmentMate at its root and the stable port Interface as PipeMate at its tip. The first or last pipe segment exposes its own endpoint Interface at the same position with the opposite outward direction; PipingMateIr records that coincidence and opposition explicitly.

The only clearance exemption is an inspectable PipingKeepOutExemptionIr scoped as NozzleEnvelopeOnly for that port's nozzle against that port's owning equipment KeepOut. It does not apply to the route, another port, another nozzle, or any foreign KeepOut. Thus a nozzle may touch its own equipment face while route and nozzle clearance remain fully enforced everywhere else.

The generic shipped product identities are Standard.Piping.Pipe, Standard.Piping.Elbow90, and Standard.Piping.Tee. Their dimensional policies are available from Use Standard.Piping. They are generic products, not ASME, DIN, or ISO parts.

Explicit routes

An explicit route is an ordered axis-aligned 3D path. The first run must follow the source port's outward direction and the final run must approach opposite the destination's outward direction.

Route SupplyRoute {
    connection: Supply;
    through: [[0mm,0mm,0mm],[300mm,0mm,0mm],[300mm,500mm,0mm]];
    bendRadius: 50mm;
    lockedSegments: [1];
    provenance: Explicit;
}

Interior anchors become semantic 90-degree turns. Straight intervals lower to hollow PipeSegment components using the declared OD and wall. Each turn lowers to a hollow analytic-torus Standard.Piping.Elbow90 occurrence with named Inlet and Outlet Interfaces. Pipe segments stop at elbow tangent points; cut length is therefore distinct from corner-to-corner route length.

For the admitted 90-degree route, a segment's cut length is its corner-to-corner interval minus one bendRadius for each adjacent interior turn: one radius at an end interval and two on an interval between two elbows. Validation rejects routes whose anchor spacing cannot accommodate those tangent setbacks.

KeepOut, clearance, and autorouting

KeepOut is semantic obstacle geometry; names have no routing meaning. Routing uses conservative axis-aligned bounds for structural members, equipment proxies, and explicit service volumes. An existing structural body is not implicitly routable space: author or generate a KeepOut from its conservative bounds. This makes avoidance semantic and inspectable instead of depending on object names.

KeepOut Frame {
    min: [400mm,-100mm,-100mm];
    max: [600mm,100mm,100mm];
    concept: StructureMember;
}
RouteSpace SkidRouting { clearance: 30mm; }
RouteRequest SupplyRequest {
    connection: Supply;
    clearance: 30mm;
    bendRadius: 50mm;
    hardWaypoints: [];
    acceptAs: SupplyRoute;
}

Forbidden centerline space is the obstacle bound inflated by pipe radius plus required clearance. Candidate search conservatively adds one bend radius to that planning inflation so an elbow torus cannot cut inside an otherwise valid sharp corner; the reported final clearance is then recomputed against the actual trimmed straights and torus centerlines without that extra planning margin. The deterministic router builds coordinates from endpoints, hard waypoints, and inflated obstacle faces, then searches the adjacent 3D coordinate graph with A*. Cost is route length plus a 1000 mm penalty per elbow, so small length savings do not add fittings. Neighbor order and priority tie-breaking are stable. Collinear search points are removed before the proposal is exposed.

RouteSpace.clearance is the system default. RouteRequest.clearance, when present, is the request-local value used for proposal and final verification; current fixtures repeat it deliberately so generated state remains self-evident. acceptAs performs the explicit acceptance step and names the materialized ordinary route. Omit acceptAs to retain a proposal without adding its route geometry when the system also has an explicit or accepted route. A system containing only unaccepted requests rejects normal engineering compilation with piping-route-required; proposal-only compilation is not admitted. Search neighbor order is +X, -X, +Y, -Y, +Z, -Z; exact anchors also depend on port positions/directions, policy radius, bend radius, hard waypoints, and obstacle bounds.

aetheris inspect source.firmament --json reports proposals separately from accepted routes. A successful proposal includes anchors, length, elbow count, minimum clearance, cost, and diagnostics. Failures distinguish endpoint direction, hard-waypoint reachability, excessive clearance, disconnection, and lock conflicts.

Local rerouting

LocalReroute authorizes one anchor interval:

LocalReroute AroundMotor {
    route: SupplyRoute;
    fromAnchor: 0;
    toAnchor: 2;
    avoid: [Motor];
    clearance: 25mm;
}

The prefix before fromAnchor and suffix after toAnchor are copied unchanged. Locks outside the interval are shifted only by the number of replacement anchors; a lock inside the interval fails with piping-local-reroute-crosses-lock. The resulting ordinary route has LocallyRerouted provenance.

Anchor and segment ordinals are zero-based. The authorized interval includes both boundary anchors but only segments with ordinals FromAnchor .. ToAnchor-1; the toAnchor and the segment leaving it begin the preserved suffix. LocalReroute updates the named route in place and retains its identity—there is no acceptAs because the operation is already an explicit authored edit. LocalReroute.clearance overrides the RouteSpace default for the replacement interval. All system KeepOuts remain active; avoid adds/names edit-specific obstacles and never disables unlisted KeepOuts.

Build and fabrication output

aetheris inspect fixtures/Canonical/Piping/autorouted-connection.firmament --json
aetheris build fixtures/Canonical/Piping/pump-skid.firmament --output artifacts/local/x3a/x3a-pump-skid.step --json

Build emits an AP242 occurrence assembly plus sibling .routing.json, .cutlist.json, and .bom.json. The routing report contains the system, equipment, ports, nozzles, endpoint mates, scoped exemptions, connections, proposals, accepted routes and their anchors/segments/turns/provenance, KeepOuts, realized pipe segments/fittings, minimum clearance, and timing evidence. The Cut List contains deterministic fabrication groups keyed by policy/material/cut length; the BOM separately groups semantic pipe, fitting, and nozzle-stub products. Routing proxies are separate named assembly components; they are not equipment-detail models. Grouping uses semantic product/policy/material and cut length, never geometry hash alone. Final qualification independently checks exact axis-aligned cylinder/nozzle centerline intervals and each realized elbow's torus centerline against the applicable original KeepOut bounds, then subtracts the pipe radius. Elbow arcs use deterministic dense sampling with the maximum chord sagitta subtracted, so the reported clearance is a conservative lower bound rather than an optimistic sample.

Bounded support

supported:

  • logical Connections independent of geometry;
  • stable port Interfaces and endpoint directions;
  • equipment-owned hollow nozzle stubs, scoped owner exemptions, and coincident endpoint mates;
  • explicit orthogonal 3D routes and 90-degree elbows;
  • deterministic local autorouting around axis-aligned KeepOut bounds;
  • hard waypoints, locked segments, and bounded local rerouting;
  • hollow analytic pipe and elbow bodies;
  • AP242 assembly, BOM, pipe Cut List, and routing evidence.

Not supported:

  • freeform or spline routing, arbitrary bends, or 45-degree elbows;
  • tees in automatic branch realization (the generic Tee product policy is shipped for future branch lowering);
  • reducers, flanges, and adapters as automatic geometry;
  • penetrations, pipe supports, spools, pressure class, or standards lookup;
  • stress, flow, gravity-slope, or plant-scale optimization.

Copy the autorouted connection fixture, local reroute fixture, or pump skid fixture as current examples.

Frontend admission

schema Piping is optional. A conflicting explicit schema rejects; Piping does not reinterpret another domain's source. The parser route in validation reports is UnifiedPiping, and valid has validation level Built: validate uses the same binding, routing, capability and geometry path as build without writing artifacts. Validate, inspect and build expose structured diagnostics with codes, messages and source locations. Existing raw diagnostic strings remain on the .NET compilation result for compatibility.

Lengths accept mm quantities and historical bare numbers interpreted as mm. Omitting document units retains the historical mm convention; an explicit conflicting unit rejects. Direction components are dimensionless. connectionType admits Generic, Flange, Weld and Threaded; enum symbols remain case-sensitive. Index lists must contain valid nonnegative integer segment indices. One optional RouteSpace sets the system default; multiple defaults reject rather than choosing the first.

Direct system children belong to their documented production owners. The existing Standard catalogue resolves Use directives and compile-time catalogue Let aliases; declaring such an alias does not instantiate its product. In particular, the shipped tee.firmament catalogue witness builds its explicitly authored straight route, not a three-way fitting. Record/Static data and existing compile- time expansion bind through the shared domain value owner, including the specialized configuration emitted by Forge. Unknown or incomplete record fields reject; unsupported declarations still reject.