Next Gen STEP AP242 Native-ish BREP Geometric Modeling Kernel
Circular Sweep
Sweep is a deliberately bounded wire-geometry primitive: a constant circular section transported along a semantic Concept Path.
Concept Path Centerline {
Start: Point2(0mm, 0mm)
Heading: 90deg
Line LeftLeg { Length: 25mm }
Arc Return { Radius: 6mm; Turn: -180deg }
Line RightLeg { Length: 25mm }
}
Sweep Wire {
Path: Centerline
Diameter: 1.2mm
Material: Standard.Materials.StainlessSteel.304_Annealed
}
Diameter is canonical and must be a positive finite Length. The path is resolved through the same domain-neutral Concept Path frontend used by profiles; Sweep does not introduce a second path model.
Limits
Supported:
- one open planar XY path;
- ordered analytic
LineandArcsegments; - tangent, continuous joins;
- one constant circular section;
- analytic cylindrical and toroidal side faces;
- planar end caps and an enclosed solid;
- AP242 export and reimport.
Not supported:
- arbitrary 3D guide curves or non-XY planes;
- sharp corners or implicit fillets;
- closed paths;
- variable/multiple profiles, rails, lofts, twist laws, or user-controlled moving frames.
Arc bend radius must exceed the section radius. Nonadjacent path regions must remain at least one wire diameter apart, plus MinimumGap when supplied. Line/line clearance is exact. Arc-involving clearance uses a deterministic conservative chord witness and is intentionally obvious-overlap coverage, not a complete general curve-distance proof.
Invalid paths fail before topology construction with segment-specific diagnostics. See the canonical Sweep fixtures and focused invalid fixtures.