Next Gen STEP AP242 Native-ish BREP Geometric Modeling Kernel
Model AutoRouteWitness {
units: mm
PipingSystem AutoWitness {
PipePolicy Pipe25 { OuterDiameter: 25mm; WallThickness: 2mm; Material: "Standard.Materials.StainlessSteel.304_Annealed"; }
Port Pump { Position: [0mm,0mm,0mm]; Direction: [1,0,0]; PipePolicy: Pipe25; ConnectionType: Flange; }
Port Cooler { Position: [1000mm,0mm,0mm]; Direction: [-1,0,0]; PipePolicy: Pipe25; ConnectionType: Flange; }
Connection Supply { From: Pump; To: Cooler; PipePolicy: Pipe25; }
KeepOut Frame { Min: [400mm,-100mm,-100mm]; Max: [600mm,100mm,100mm]; Concept: StructureMember; }
RouteSpace Skid { Clearance: 30mm; }
RouteRequest SupplyRequest { Connection: Supply; Clearance: 30mm; BendRadius: 50mm; HardWaypoints: []; AcceptAs: SupplyRoute; }
}
}