Next Gen STEP AP242 Native-ish BREP Geometric Modeling Kernel
Model InvalidRibThickJunction { Units: mm PlasticShell Housing {
Exterior: Frustum BottomRadius: 50 mm TopRadius: 52 mm Height: 20 mm Material: ABS ToolingDirection: [0,0,1] MinimumDraftAngle: 3 deg Preserve: [ExteriorDesignSurface]
WallPolicy { NominalThickness: 2.2 mm MinimumThickness: 2.1 mm MaximumThickness: 2.3 mm ThicknessTolerance: 0.05 mm }
PartingPlane P { Origin: [0,0,20] Normal: [0,0,1] } Gate G { Kind: Edge Position: [0,52,20] Target: TopAnnularRim Size: 1 mm }
Standoff A { Position: [-20,-20,2.2] Height: 8 mm OuterDiameter: 12 mm HoleDiameter: 2 mm SupportIntent: Pcb } Standoff B { Position: [20,-20,2.2] Height: 8 mm OuterDiameter: 12 mm HoleDiameter: 2 mm SupportIntent: Pcb }
Standoff C { Position: [20,20,2.2] Height: 8 mm OuterDiameter: 12 mm HoleDiameter: 2 mm SupportIntent: Pcb } Standoff D { Position: [-20,20,2.2] Height: 8 mm OuterDiameter: 12 mm HoleDiameter: 2 mm SupportIntent: Pcb }
EjectorPin E { Position: [0,-30,2.2] Diameter: 3 mm Target: InnerBottom }
AutoRib R { Support: [A,B,C,D] Gate: G KeepOut: [] RibPolicy { ThicknessRatio: 1.0 MinimumHeight: 3 mm MaximumHeight: 7 mm MinimumSpacing: 4 mm DraftAngle: 3 deg BaseBlendRadius: 0.8 mm } }
} }