Next Gen STEP AP242 Native-ish BREP Geometric Modeling Kernel
Model LocalRerouteWitness {
Units: mm
PipingSystem LocalWitness {
PipePolicy Pipe25 { OuterDiameter: 25mm; WallThickness: 2mm; Material: "Standard.Materials.StainlessSteel.304_Annealed"; }
Port Pump { Position: [0mm,0mm,0mm]; Direction: [1,0,0]; PipePolicy: Pipe25; ConnectionType: Flange; }
Port Cooler { Position: [1000mm,300mm,300mm]; Direction: [-1,0,0]; PipePolicy: Pipe25; ConnectionType: Flange; }
Connection Supply { From: Pump; To: Cooler; PipePolicy: Pipe25; }
KeepOut Motor { Min: [250mm,-50mm,-50mm]; Max: [450mm,150mm,150mm]; Concept: EquipmentProxy; }
RouteSpace Skid { Clearance: 28mm; }
Route SupplyRoute { Connection: Supply; Through: [[0mm,0mm,0mm],[500mm,0mm,0mm],[500mm,300mm,0mm],[500mm,300mm,300mm],[1000mm,300mm,300mm]]; BendRadius: 50mm; LockedSegments: [2]; Provenance: AutoGenerated; }
LocalReroute AroundMotor { Route: SupplyRoute; FromAnchor: 0; ToAnchor: 2; Avoid: [Motor]; Clearance: 28mm; }
}
}