Lightweight server monitoring with historical data, docker stats, and alerts.
fix(agent): keep LHM helper alive after sensor failures (#2624)
Jimmy Liu Jiae84eb25e1c6d
diff --git a/agent/lhm/beszel_lhm.cs b/agent/lhm/beszel_lhm.csindex 638128795..9dc3ce052 100644--- a/agent/lhm/beszel_lhm.cs+++ b/agent/lhm/beszel_lhm.cs@@ -51,8 +51,7 @@ class Programvar updated = false;foreach (var sensor in hardware.Sensors){- var validTemp = sensor.SensorType == SensorType.Temperature && sensor.Value.HasValue;- if (!validTemp ||+ if (sensor.SensorType != SensorType.Temperature ||sensor.Name.IndexOf("Distance", StringComparison.OrdinalIgnoreCase) >= 0 ||sensor.Name.IndexOf("Limit", StringComparison.OrdinalIgnoreCase) >= 0 ||sensor.Name.IndexOf("Critical", StringComparison.OrdinalIgnoreCase) >= 0 ||@@ -64,10 +63,25 @@ class Programif (!updated){- hardware.Update();+ try+ {+ hardware.Update();+ }+ catch (Exception ex)+ {+ Console.Error.WriteLine($"Could not update {hardware.HardwareType} {hardware.Name}: {ex.Message}");+ return;+ }updated = true;}+ // Read the value once after Update(), which may reset it to null.+ var temperature = sensor.Value;+ if (!temperature.HasValue)+ {+ continue;+ }+var name = sensor.Name;// if sensor.Name starts with "Temperature" replace with hardware.Identifier but retain the rest of the name.// usually this is a number like Temperature 3@@ -77,7 +91,7 @@ class Program}// invariant culture assures the value is parsable as a float- var value = sensor.Value.Value.ToString("0.##", CultureInfo.InvariantCulture);+ var value = temperature.Value.ToString("0.##", CultureInfo.InvariantCulture);// write the name and value to the writerwriter.WriteLine($"{name}|{value}");}