Open-source manufacturing ERP, MES and QMS. Quoting, MRP, inventory, shop floor, quality and lot/serial traceability on one Postgres schema, with a REST API and MCP server. Self-host or use Carbon Cloud.
BOM-Driven Subassembly Planning — Plan Nested Units, Not Leaf Soup
Problem
A real customer model ("431 parts") planned for 11 minutes and produced
hundreds of junk steps. The assembly is really 7 BOM lines — one of them a
purchased PCB whose 3D model carries hundreds of tiny child solids (chips,
caps, connectors). Today the planner flattens every leaf mesh into an
independent rigid body (_collect_world_parts in services/geometry/app/plan.py
discards the hierarchy), so it fights 400+ bodies that can never separate in
real life, then step generation surfaces them all.
Everything needed to fix this already exists in the system:
| Signal | Where it lives | State |
|---|---|---|
| CAD hierarchy (PCB = one subassembly node) | graph.json (convert.py preserves isAssembly + children) |
built, ignored by planner |
| Engineering BOM (7 items) | getFlattenedBomMaterials(client, itemId, companyId) |
built |
| Geometry ↔ BOM item mapping | assemblyPartMapping (geometryHash → itemId), auto-matched by autoMatchAssemblyParts (nameSimilarity ≥ 0.45 greedy) |
built |
| Persisted "these nodes are one unit" | assemblyGroup table (becomes lean assemblyUnit per D0) |
built, display-only |
| One-step-per-unit playback | plan.json v2 groups: { gN: { partNodeIds, motion } } → buildAssemblyStepGroups makes a group ONE step; AssemblyPlayer animates it |
built |
The change is therefore mostly wiring: derive the planned units in TS from BOM + hierarchy + authored units, hand them to the planner, and let the planner treat each unit as a single rigid body. Collapsing 431 → ~7 bodies also collapses the O(N²) collision work — this should take the 11-minute run back to well under a minute.
Prerequisite (uncommitted work in tree)
The async /plan refactor (submit → 202 + poll GET /plan/{jobId}, worker
polls via step.sleep) is already implemented and typechecked in the working
tree (services/geometry/app/main.py, schemas.py,
packages/jobs/src/inngest/functions/tasks/assembly-plan.ts). It fixes the
UND_ERR_HEADERS_TIMEOUT retry-storm on long plans. Commit it first (or with
Task 3) — this plan builds on that flow.
Design
D0. One grouping concept: the Subassembly (drop the parity taxonomy)
The assemblyGroup types Cluster / Kit / Combination are leftovers of
the abandoned feature-parity direction: all three are display-only (nothing
consumes them), kitting belongs on the materials side if it ever returns, and
"Combination = parts treated as one unit" is superseded by BOM-driven unit
derivation. assemblyInstructionStep.groupIds is a dead column (no reads or
writes anywhere).
childInstructionId goes too (user-confirmed): instructions attach to
items, and each BOM level is its own item — a Make subassembly's item gets
its own assemblyInstruction with its own model. The parent instruction never
spawns or links child instructions; it just consumes the subassembly as one
part. With that gone, nothing about the override is instruction-specific, so
the row rescopes from assemblyInstructionId to modelUploadId — the same
scoping (and survival semantics across instruction delete/recreate) as
assemblyPartMapping. The worker also only has modelUploadId, so derivation
reads it directly.
Simplify while the branch is unshipped (user-confirmed):
- Schema — edit migration
20260611134652_assembly-editor-parity.sqlin place: replaceassemblyGroupwith a leanassemblyUnittable —id, modelUploadId (FK modelUpload, CASCADE), name, partNodeIds TEXT[],itemId TEXT NULL (mapped BOM item), companyId, audit fields. Drop theassemblyGroupTypeenum,childInstructionId,partNumber, andassemblyInstructionStep.groupIds(dead column). Local DB patch (no rebuild): dropassemblyGroup+ the enum + thegroupIdscolumn, createassemblyUnit(exact SQL written at execution time from the edited migration). Then regenerate DB types (pnpm run generate:types) BEFORE typechecking. - Models/service —
assemblyUnitValidator,get/upsert/deleteAssemblyUnitreplace the group equivalents (mechanical rename + simplification; routes$id.groups.*→$id.units.*). - UI — BOM tree "Groups" section becomes "Subassemblies" (label stays
in manufacturing language even though the table is
assemblyUnit); the four-option Group dropdown becomes one "Create subassembly" action.
D1. Unit derivation is a pure TS function (BOM is the source of truth)
New deriveAssemblyUnits in packages/viewer/src/units.ts (pure — no DB, no
IO — so it unit-tests trivially and both the worker and the UI can call it):
type AssemblyUnit = {
id: string; // subtree root nodeId (or authored unit id)
name: string; // BOM item name > node name
nodeIds: string[]; // member LEAF nodeIds (what the planner merges)
itemId?: string; // BOM item this unit maps to, when known
source: "authored" | "bom" | "hierarchy";
};
function deriveAssemblyUnits(args: {
graph: AssemblyGraph;
bomMaterials: { itemId: string; name: string | null }[];
partMappings: { geometryHash: string; itemId: string }[];
authoredUnits: { id: string; partNodeIds: string[] }[]; // assemblyUnit rows
}): AssemblyUnit[];
Rules, in precedence order:
- Authored
assemblyUnitrows are explicit units (the user's override — both "collapse this" and, by deleting the unit, "expand this"). - Unwrap wrappers: descend through single-child assembly chains from the
root (STEP exports often nest
Product → Assembly → actual children). - Top-level candidates: the (unwrapped) root's direct children. A leaf child is a unit of itself.
- BOM refinement for assembly-node candidates:
- If the node (or its subtree) corresponds to ≤ 1 BOM item — via
nameSimilarity(nodeName, bomName)at the thresholdautoMatchAssemblyPartsalready uses, or because every mapped leaf inside it maps to the same item — collapse it into one unit (the PCB case). - If the node does NOT correspond to a BOM item but its children match several BOM items, descend one level and re-apply (handles gratuitous grouping layers).
- No BOM / no matches → keep the top-level-only fallback (collapse the subassembly node as one unit). Flat models (all leaves at root) behave exactly as today.
- If the node (or its subtree) corresponds to ≤ 1 BOM item — via
nameSimilarity moves from production.service.ts to a shared pure module
(packages/viewer/src/similarity.ts or @carbon/utils) and is re-imported by
the service — one implementation, not two.
D2. Planner contract: options.units, plan version 3
POST /plan request gains an optional field (geometry service stays dumb —
it receives geometry decisions, it doesn't make BOM decisions):
"options": {
"units": [ { "id": "nodeId-of-subtree", "name": "PCB Assembly", "nodeIds": ["leaf1", "leaf2", ...] } ]
}
In plan_step / _collect_world_parts: leaves listed in a unit concatenate
into one _Part (single trimesh, node_id = unit.id). Contacts inside a
unit are self-exempt by construction. Multi-member units emit into plan.json
as the existing v2 groups shape (partNodeIds = member leaves, shared
motion) plus an additive optional name — downstream step generation and the
viewer already handle groups as one step.
Bump PLAN_VERSION (plan.py) and CURRENT_PLAN_VERSION
(packages/viewer/src/plan.ts) 2 → 3 so pre-grouping plans are treated as
absent and auto-replan — same staleness mechanism that retired v1.
D3. Worker derives units before submitting
assembly-plan.ts start-plan step, before the POST: download graph.json
(small), load BOM (modelUpload → assemblyInstruction.itemId → getFlattenedBomMaterials equivalent via service role), assemblyPartMapping
rows, and assemblyUnit rows (all modelUploadId-scoped); call deriveAssemblyUnits;
pass options.units. No instruction/BOM found → pass only hierarchy-derived
units (the function handles empty inputs).
D4. UI: units in the BOM tree + re-run
AssemblyBomTree.tsx gains a subassembly-node view: an assembly node that was
(or would be) collapsed renders as one row — name, member count, mapped BOM
item — with a "Plan as one part" toggle that upserts/deletes the
assemblyUnit (partNodeIds = subtree leaf ids). This
also de-noises the current distinct-parts list (the PCB's 300 internals fold
into one row). The existing Re-run plan action
($id.plan.rerun.tsx) already covers "apply my change".
D5. Step generation niceties
buildAssemblyStepGroups passes the group name through so the draft step
titles read "Install PCB Assembly" instead of a 300-part enumeration
(describeStep prefers the group name when present). Auto-linking the step's
assemblyInstructionStepMaterial to the unit's mapped itemId is a natural
follow-up — noted, not in this pass.
Tasks
T0 — Commit the async /plan prerequisite already in tree. Verify:
pnpm exec turbo run typecheck --filter=@carbon/jobsgreen;services/geometry/.venv/bin/python -m pytest -qgreen.T0.5 — Simplify the group model (D0) Files:
packages/database/supabase/migrations/20260611134652_assembly-editor-parity.sql(in-place edit), local psql patch (SQL in D0),pnpm run generate:types,production.models.ts,production.service.ts,AssemblyBomTree.tsx(Subassemblies section, single create action), routes$id.groups.*→$id.units.*(no child-instruction creation). Verify:pnpm exec turbo run typecheck --filter=erpgreen; BOM tree renders and creates a subassembly locally.T1 —
deriveAssemblyUnits+ sharednameSimilarityFiles:packages/viewer/src/units.ts(new),packages/viewer/src/units.test.ts(new), movenameSimilarityout ofproduction.service.ts, export frompackages/viewer/src/index.ts. Tests: wrapper unwrap; flat model → per-leaf units; PCB-like fixture (7 children, one with 300 leaves + BOM of 7) → 7 units; authored unit precedence; descend-when-no-BOM-match. Verify:pnpm --filter @carbon/viewer testand typecheck green.T2 — Geometry service: units + PLAN_VERSION 3 Files:
services/geometry/app/schemas.py(PlanOptions.units),services/geometry/app/plan.py(plan_step(units=...), merge in_collect_world_parts, emitgroupswithname,PLAN_VERSION = 3),services/geometry/tests/test_plan.py(nested fixture viatests/fixtures/make_fixtures.py: enclosure + board-with-children → collapsed unit plans as one body, group payload carries members + name). Verify:services/geometry/.venv/bin/python -m pytest -qgreen.T3 — Worker passes units File:
packages/jobs/src/inngest/functions/tasks/assembly-plan.ts— fetch graph/BOM/mappings/groups, callderiveAssemblyUnits, sendoptions.units. Verify: typecheck green; local run (see T6).T4 — Viewer/step-gen: v3 + names Files:
packages/viewer/src/plan.ts(CURRENT_PLAN_VERSION = 3, parse optional groupname, title passthrough inbuildAssemblyStepGroups),packages/viewer/src/plan.test.ts. Verify:pnpm --filter @carbon/viewer testgreen.T5 — BOM tree unit rows + toggle Files:
apps/erp/app/modules/production/ui/Assemblies/AssemblyBomTree.tsx,production.service.ts(group upsert already exists — reuse), route for the toggle if one doesn't fit an existing action. Verify: typecheck; browser check in T6.T6 — End-to-end on the real model Re-upload (or plan.rerun) the 431-part model: expect ~7 planned units, plan runtime ≪ 11 min (target < 2 min), Generate Steps produces ~7 draft steps with sane titles, PCB animates as one unit. Verify:
assemblyPlanJobrow Success + timing; steps count; visual check.T7 — Spec + docs sync Update
.ai/specs/2026-07-04-animated-work-instructions-contracts.md(units option, v3, group name) and the production moduleAGENTS.mdrow forgenerateAssemblyStepsFromPlan/plan pipeline.
Risks / notes
Name-similarity misgrouping: a subassembly wrongly collapsed hides real steps. Mitigations: only subtree candidates are eligible (never arbitrary node sets), the BOM tree shows what collapsed and why, and the toggle undoes it per model. The failure mode is conservative (fewer, coarser steps), not corrupt motion.
No instruction/BOM at plan time (model uploaded standalone): derivation degrades to hierarchy-only — still strictly better than today's flat soup.
Collision cost of merged meshes: a collapsed PCB keeps its full triangle count in one body; pair count drops quadratically so net runtime falls sharply. If a pathological model is still slow, decimating unit collision meshes is the follow-up lever (not in this pass).
Plan v3 staleness bump auto-invalidates every existing v2 plan — intended (they're leaf-soup plans), but note reruns will trigger on next Generate Steps for existing models.
assemblyUnit.partNodeIdsvs re-uploads: nodeIds are stable per the nodeId contract for the same geometry; a changed model re-derives units fresh (authored units referencing vanished nodeIds are skipped by derivation).Two meanings of "group": plan.json
groups(wire format for a multi-part planned unit) is unrelated to theassemblyUnittable (persisted subassembly override). Post-D0 nothing DB-side is called a "group", which dissolves the collision.
Revision — CAD is flat, group by BOM membership (2026-07-06)
Inspecting the real model (SA-BCU, 431 leaves) disproved the nesting
assumption: the STEP export is completely flat — all 431 solids are direct
children of the root, no subassembly nodes. The PCB's ~400 component solids
(R_0402, SOT-23, PG-TSDSO, minimalBCU_gen2_PCB, …) are top-level
siblings of the enclosure, seal, and screws. The BOM has 7 lines including
BCU PCB (qty 1).
So units cannot come from the tree. deriveAssemblyUnits is rewritten to group
by BOM membership:
- The LLM (
assignPartsToBom, gpt-4o-mini) assigns each distinct part name to a BOM line — electronic footprints → the PCB line — since text similarity can't (minimalBCU_gen2_PCBvsBCU PCBscores 0.25;R_0402shares nothing withBCU PCB). Exact geometry↔BOM mappings win over the LLM guess. - Leaves group by assigned item. A group collapses into one rigid body only when quantity ≤ 1 and it has ≥ 2 leaves (a single subassembly shown in detail — the PCB). Multi-quantity lines (8 screws, 4 clips) stay separate bodies; the viewer's identical-part grouping still merges them into a step.
- The qty≤1 heuristic is imperfect (user: "1 seems most correct… may not be
true in other instances") — the T5 manual override (
assemblyUnit) is the escape hatch for the exceptions.
Replaces the hierarchy-unwrap/descend rules and assemblyUnitCandidates from
the original D1. AssemblyUnit.source is now authored | bom | loose. The
worker sends only collapsed (multi-leaf) units as options.units.
T6 result — verified on SA-BCU (2026-07-06)
Triggered a fresh plan for the real 431-leaf model end-to-end:
- LLM assigned all 431 leaves, 0 unmatched: 412 → BCU PCB, 8+4 screws, 4 clips, seal/lid/box (~1s, gpt-4o-mini).
- Geometry planned ~20 bodies in 105s (was 431 bodies / ~11 min).
- plan.json v3 with two collapsed units:
BCU PCB(411 members) andElectronics Box - 36 Pin(2 members). - buildAssemblyStepGroups over the real graph → 431 parts render as 11 steps, the PCB one step titled "BCU PCB".
- Caveat: the merged PCB and Box bodies flag (motion "none", fade in) — no collision-free insertion into the sealed enclosure. Structurally correct; motion quality is a follow-up (manual motion or an authored split).
Execution log (running)
- 2026-07-06 — Plan drafted; rule = BOM-driven with top-level hierarchy fallback + authored-group override (user-confirmed).
- 2026-07-06 — D0 added: collapse the parity taxonomy to Subassembly-only, in-place migration edit + local psql patch (user-confirmed).
- 2026-07-06 — D0 revised: no child instructions at all (instructions attach
to items; each BOM level's item has its own instruction), so the override
rescopes to
modelUploadIdas leanassemblyUnit(user-confirmed).