MES Serial Selector Picker (scan/select unit on a later operation)

Last tested: 2026-08-04 App: MES Route: /x/operation/:operationId (standard Process operation view, not Assembly/Inspection)

Verifies the serial picker (SerialSelectorModal, driven by useOperation) prompts once on arrival, stays dismissed across loader revalidations, and re-opens only on the completion edge or via the Scan button.

Prerequisites

  • A Make item with itemTrackingType = 'Serial'.
  • An itemSerialSequence row for that item — without it the job's tracked entity stays a single quantity-N seed and never splits into N quantity-1 serial units (assignJobSerialNumbers in production.service.ts skips the assign-serial-numbers edge function when no sequence exists).
  • Its method has ≥2 operations with a non-Assembly, non-Inspection process (processType Process), so the standard operation view renders.
  • A released job (release is what writes jobOperationDependency, which is how the loader decides isFirstOperation).

Fast seed (dev DB)

update item set "itemTrackingType"='Serial' where "readableId"='FG-1';
insert into "itemSerialSequence" ("companyId","itemId",prefix,next,size,step,"createdBy")
values ('<companyId>','<itemId>','FG1-',1,4,1,'<userId>');

Then ERP UI: /x/job/new → item, quantity 3 → Save → Release → Release Job. Find the non-first op:

select jo.id, jo.status,
  (select count(*) from "jobOperationDependency" d where d."operationId"=jo.id) as prior_deps
from "jobOperation" jo where jo."jobId"='<jobId>' order by prior_deps;

prior_deps = 1 is the target (later operation).

Steps

1. Login

MES shares ERP cookies, but opening a deep MES link while unauthenticated bounces to an internal 127.0.0.1:<port>/login where the dev bypass does not apply (it mails a magic link). Log in on ERP_URL/login first, then open MES_URL/x once, then the operation URL.

2. Arrival — open /x/operation/<laterOpId>

Expect exactly 1 [role=dialog] ("Select Serial Number"), and no ?trackedEntityId in the URL (only the first operation gets one seeded by the loader).

3. Dismiss + churn (the regression)

Escape, then force loader revalidations — a job row UPDATE fires the realtime subscription in useOperation, which calls revalidator.revalidate():

update job set "updatedAt"=now() where id='<jobId>';

Expect document.querySelectorAll('[role=dialog]').length === 0 after each. Repeat 3–4×.

4. Scan button re-opens

Click the Scan button in the Serial Numbers section → picker returns.

5. Select a unit → quiet

Select tab → Select on a serial. URL gains ?trackedEntityId=<id>, dialog closes, and stays closed across further job UPDATEs.

6. Completion edge → re-opens once

Mark the held unit complete for this operation, then revalidate:

update "trackedEntity" set attributes = attributes ||
  jsonb_build_object('Operation <opId>', now()::text) where id='<heldEntityId>';
update job set "updatedAt"=now() where id='<jobId>';

Picker re-opens. Dismiss it → stays closed across further revalidations.

7. First operation unaffected

Open the prior_deps = 0 op → loader seeds ?trackedEntityId, no dialog.

Selector Notes

  • Modal detection: document.querySelectorAll('[role=dialog]').length — the picker has no stable test id; its text starts "Select Serial Number".
  • The picker opens on the Scan tab; click the Select tab to get per-unit Select buttons.
  • The Serial Numbers section's Scan button is the only manual re-open affordance.

Common Failures

  • Picker re-opens after every dismiss — the regression this playbook covers. Level-triggered re-prompt (if (!selectedIsIncomplete) serialModal.onOpen()) fires on every revalidation because trackedEntities gets a fresh array identity each time. Fixed by the edge-triggered heldEntityRef in useOperation.
  • No picker at all — jobMakeMethod.requiresSerialTracking false (item wasn't Serial when the job was created), or the op has no jobOperationDependency (job not released → treated as the first operation → auto-select).
  • Only one tracked entity of quantity N — no itemSerialSequence; the seed never split into serial units.