OEE Provider integration (first provider: Sense)

Status: implemented (PR #1909) Author: barbinbrad Date: 2026-10-12

Where the build differs from the first draft (the code wins; .claude/rules/oee-provider.md):

  • Unattributed machine time is a review queue with no status. Assign and dismiss delete the row. There is no dismiss reason and no Reopen.
  • The MES operation page shows no device badge. Only the work center display shows the device state.
  • The loaded operation is a history table, workCenterLoad. The open row is the load. workCenter has no pointer column.
  • The engine gives each moment of a run to an owner. Open sensor time follows its owner when a load, a block or a press changes it.
  • The MES press rules apply on every work center, with or without a device.
  • The OEE tables are read-only through the API. A device maps only to its own company's work center (composite FK). Carbon refuses Sense staging (plain HTTP) in production.

TLDR

An OEE provider is a machine-monitoring vendor. It reports whether each machine is running. OEE providers are a new class of integration, like accounting providers. A company can have more than one OEE provider active. Every provider uses the same interface, the same sync job and the same mapping screen.

Sense is the first provider. Sense clips a current sensor onto each machine and reports state changes per device. Sense calls a device a station.

The first step is the device mapping: the user pairs each provider device with one Carbon work center. When a device reports that its machine runs, Carbon creates a Machine productionEvent on that work center. The event goes to the work center's loaded operation. That is the job operation that a person last started on that work center. If nothing is loaded, the run goes to an unattributed machine time list. A supervisor assigns it to a job operation or dismisses it.

Overview diagram

sequenceDiagram
    participant S as Sense API
    participant J as oee-sync job
    participant D as Carbon database
    participant O as MES operator
    participant V as ERP supervisor
    O->>D: Start Setup on op A (loads A)
    J->>S: GET device events since cursor
    S-->>J: Active at 10:00
    J->>D: Open Machine event on op A
    O->>D: Press Machine Pause at 10:30 (ends the event)
    S-->>J: Idle at 11:00, Active at 11:05
    J->>D: Queue 10:30 to 11:00, open new event on A at 11:05
    D->>D: Op A Done unloads A
    J->>D: End A's event at the unload, queue the rest of the run
    V->>D: Assign the queued time to op B

Problem Statement

Carbon records machine time only when an operator starts and stops the Machine timer in MES. Operators forget, and machines often run unattended after setup. So job cost is low, and the work center utilization KPI is wrong.

Shops already install machine-monitoring sensors. A current clip knows only whether the machine is on. It does not know which job runs. Carbon cannot use the top of the schedule: operators skip operations for missing parts and expedites. Carbon cannot use the operator's clock-in either: an operator sets up a machine, stops the timer and walks away while the machine runs.

Sense is the first vendor. Its public API (http://bifrost-staging.sensemfg.com/docs) has these endpoints:

Endpoint Returns
GET /v1/public/companies/sites sites, each with id, name, timezone
GET /v1/public/companies/stations stations, each with id, machine_name, machine_manufacturer, machine_type, machine_model, site_id, last_calibration_attempt_status
GET /v1/public/companies/sites/{site_id}/stations/{station_id}/events state changes, each with id, status, created_at (UTC). Query: start_datetime, end_datetime, order, limit, offset, statuses
GET …/stations/{station_id}/telemetry power and vibration samples, one per minute (not used in v1)

The status values are Active, Idle, Alert and Offline. Sense has no webhooks, so Carbon must poll. The API key is company-scoped: Sense finds the company from the key. On 2026-10-12 the staging company had 3 sites and 55 stations. One site (Reston - 2) had the timezone UTC.

Research: .ai/research/oee-provider-integration.md. No surveyed product infers the job from an on/off signal. Each product keeps one active job per machine, and a person or the ERP sets it. MachineMetrics keeps unmatched run time as an "Unknown Job" that a person assigns later. This spec copies both patterns.

Proposed Solution

1. The OEE provider class

An OEE provider is an integration with providerRole: "oee". Every OEE provider implements one interface in packages/ee/src/oee/types.ts:

type MachineState = "Running" | "Idle" | "Down" | "Offline";

interface OeeDevice {
  externalDeviceId: string;
  name: string;
  externalSiteId: string | null;
  siteName: string | null;
  siteTimezone: string | null;
  manufacturer: string | null;
  model: string | null;
  machineType: string | null;
  calibrated: boolean | null;
}

interface OeeStateChange {
  externalEventId: string;
  state: MachineState;
  changedAt: string; // UTC ISO 8601
}

interface OeeProvider {
  id: OeeProviderId;
  validate(): Promise<{ valid: boolean; error?: string }>;
  listDevices(): Promise<OeeDevice[]>;
  listStateChanges(
    device: { externalDeviceId: string; externalSiteId: string | null },
    window: { since: string; until: string }
  ): Promise<OeeStateChange[]>;
}

getOeeProvider(client, companyId, integrationId) builds the provider from the company's companyIntegration row. It reads the API key from Vault with resolveIntegrationSecrets.

getOeeProvider finds the constructor in a registry, OEE_PROVIDERS (packages/ee/src/oee/registry.ts), which maps an integration id to a factory. Code outside the registry never branches on an integration id. The no-integration-id-branching check enforces this, so add "sense" to its INTEGRATION_IDS and its provider-directory exclusion. Code that must find the OEE integrations calls getIntegrationIdsByRole("oee"). A second provider adds one adapter and one registry entry. The sync job, the mapping screen and the attribution engine stay the same.

The Sense adapter (packages/ee/src/sense/) maps Sense statuses to MachineState with an explicit allowlist:

Sense status MachineState
Active Running
Idle Idle
Alert Down
Offline Offline

If Sense returns another status, the adapter throws. The sync job then fails that device and keeps its cursor (.ai/lessons.md → "Financial discriminators require explicit verified allowlists").

Sense ignores offset, and offset=0 returns HTTP 400 (verified against staging on 2026-10-13). So the adapter pages by time: it requests order=asc&limit=500, and if the page is full it requests again from the last event's created_at. It drops events it has already seen, by id, and stops when a page is short or adds nothing new.

2. Installing Sense

Settings → Integrations → Sense. The descriptor packages/ee/src/sense/config.tsx copies the Rillet descriptor. It has 3 settings:

Setting Type Default
apiKey secret none (required)
environment options: Production (https://bifrost.sensemfg.com), Staging (http://bifrost-staging.sensemfg.com) Production
minimumStateSeconds number 60

onHealthcheck calls validate(), which calls GET /v1/public/companies/sites.

3. Device mapping

The drawer of each OEE integration gets a Devices tab. The loader calls listDevices() and reads the mappings in parallel. Redis caches the device list for 60 seconds. Each integration save clears the cache. The tab shows one row per device:

Column Source
Device name, then manufacturer, model and machine type as muted text
Site siteName
Calibrated calibrated as a badge
Work center a Combobox of active work centers, plus a mapped work center that is inactive

Rules:

  1. The user picks a work center and saves the row. The action upserts a workCenterDevice row. It stores the name, site and site timezone of the device in the current provider list, not the form's values.
  2. If the device is not in the current provider list, the action refuses.
  3. If the work center already has a device from any OEE provider, the action refuses. The message names the other device and provider. The combobox leaves out the work centers that another device holds.
  4. If the device's site timezone differs from the work center's location timezone, the row shows a warning icon. The tooltip names both timezones. A location with no timezone (null or '') uses the company's. Carbon uses the location timezone for all local time.
  5. The user clears the combobox to unmap. The action ends the time that the device's sensor opened on the work center (endSensorMachineTime). Then it deletes the workCenterDevice row. A remap does the same on the old work center and inserts a new row.
  6. A new mapping charges no time before the moment of the save. The first sync reads the 24 hours before the mapping only to learn the starting state.

4. The loaded operation (community)

The table workCenterLoad holds the loads of each work center. Each row has jobOperationId, loadedAt and unloadedAt. The row with unloadedAt null is the loaded operation. The loaded operation is the operation that is physically on the machine. It does not depend on a sensor, so it is AGPL code. It exists on every work center, with or without a device.

Two interceptors write the table. The API can only read it.

  1. A writer inserts a productionEvent row with endTime IS NULL and a workCenterId. Then sync_load_work_center_operation loads the row's operation. Setup, Labor and Machine starts all load. So does the QR start (/x/start/:operationId).
  2. The interceptor takes a transaction advisory lock for the work center. Loads on one work center run one at a time.
  3. If the event's startTime is earlier than the newest loadedAt or unloadedAt of the work center, the interceptor writes nothing. A late event never undoes a later load or unload.
  4. If the operation is already loaded, the interceptor writes nothing.
  5. Else the interceptor ends the open row at startTime. Then it inserts a row with loadedAt = startTime.
  6. A row inserted with an endTime (an ERP entry or an assigned interval) never loads. An event loads only its own company's operation onto its own company's work center.
  7. sync_unload_work_center_operation ends the operation's open row. It does this when the status changes to Done or Canceled, when the operation is deleted, and when it moves to another work center. It sets unloadedAt = GREATEST(NOW(), loadedAt).
  8. Stopping a timer does not unload the operation. That is what lets an unattended run reach the job.

The interceptor has no status rule. A starting event reopens a Done operation first (sync_set_job_operation_in_progress, a BEFORE interceptor).

A CHECK refuses unloadedAt < loadedAt. A partial unique index allows one open row per work center. jobOperationId has no foreign key. A second relationship between jobOperation and workCenter makes PostgREST refuse the existing embeds between the two tables (PGRST201).

The sync reads this history. A run that the provider reports late goes to the operation that was loaded when the machine ran.

The MES work-center display (/display/:workCenterId/work) shows the loaded operation. It reads loadedJobOperationId from the view workCentersWithBlockingStatus, which takes it from the open row. If the work center has a workCenterDevice, the display also shows the machine state.

pg_cron deletes a row 7 days after its unloadedAt. It keeps the row longer while a device on the work center has not planned past the unload (appliedThrough is null or earlier than unloadedAt). It never deletes an open row.

5. Attribution rules

The engine is a pure function, planMachineTime, in packages/ee/src/oee/engine.ts. It returns a list of writes. The sync job applies them.

Inputs.

Input Meaning
loads The work center's loads in the planned window. Each has jobOperationId, from, to and assignable.
blocks The periods when maintenance blocks the work center (from, to).
lastManualChangeAt The latest operator press.
firstUnplannedPressAt The earliest press since the last sync (workCenterDevice.unplannedPressAt).
openMachineEvent The newest open Machine event on the work center: id, jobOperationId, startTime, and system (true when the sync created it).
openUnattributed The open unattributed row.
lastMachineEventEndTime The latest Machine endTime after currentStateAt.
recordedIntervals The Machine events and unattributed rows in the window: id, kind, startTime, endTime.
currentState, currentStateAt The applied state.
mappedAt, minimumStateSeconds, now The mapping time, the debounce and the clock.
changes The stored changes after appliedThrough, in time order.

assignable is false when the operation is Done or Canceled, when its job is locked (Completed, Closed or Cancelled), or when the operation no longer exists. machineTimeRefusal (packages/ee/src/oee/assignable.ts) holds this rule. The sync, the assign write and the ERP suggestion cards all use it.

The owner rule. The sensor decides whether the machine ran. The owner of each moment of a run decides who gets the time:

  1. If maintenance blocks the work center at that moment, the owner is the queue.
  2. If an operator pressed Machine after the run started, and at or before that moment, the owner is the queue. The press stopped the operator's time, not the machine.
  3. Else, if the operation loaded at that moment is assignable, the owner is that operation.
  4. Else the owner is the queue.

"The queue" is unattributedMachineTime. The owner changes only at an edge: a load begins or ends, a block begins or ends, or a press. The engine splits each stretch of run time at these edges and gives each piece to its owner. It never records time that a Machine event or an unattributed row already holds. So the same facts give the same result in any order of arrival.

A closed piece for an operation becomes a Machine event with employeeId = null and createdBy = system. The engine drops a closed queue piece shorter than minimumStateSeconds. A piece that reaches the present while the machine runs stays open. A queue piece opens only after it lasts minimumStateSeconds.

Debounce. The engine drops a state that lasts less than minimumStateSeconds. The previous state continues through it. The engine applies a state change only after the change has lasted minimumStateSeconds, or after the next change confirms it. Repeated reports of one state count as one run.

Applied state. currentState is the state the engine applied last. currentStateAt is the time that state began. appliedThrough is the changedAt of the last stored change the engine consumed, applied or dropped. Each sync reads the machineStateChange rows after appliedThrough. A change that has not yet lasted minimumStateSeconds stays pending, and the next sync reads it again.

First sync. A new device has no currentState. The first sync reads from 24 hours before the mapping. The engine takes the last change before the mapping as the starting state, at the time of the mapping. So a machine that was already running when the user mapped it opens time from the mapping, never earlier.

State changes. For each new state change, in time order:

  1. If the state does not change, skip it.
  2. If changedAt <= lastManualChangeAt, the provider reported the change late. The press already decided the time after it. A late run is recorded closed by the owner rule, up to the press or up to an earlier stop. A late stop trims the queue (see "Time around a press").
  3. If the state is Running and a Machine event or an unattributed row is open, do nothing.
  4. If the state is Running, open time for the owner at changedAt: a Machine event on the loaded operation, or an unattributed row.
  5. If the state is Idle, Down or Offline, end the open Machine event and the open unattributed row at changedAt.

Open time follows its owner. An open sensor event or open unattributed row closes at the first edge where its owner changes. The new owner gets the rest of the run. Examples:

  • An operator starts Setup on operation B while a sensor event runs on A. The next sync ends the event on A at B's loadedAt. It opens an event on B at the same instant.
  • Maintenance ends while the machine runs. The open unattributed row ends, and an event on the loaded operation opens.
  • Operation A goes Done while the machine runs. The unload ends A's load, so A's event ends at the unload. The rest of the run goes to the queue.

An operator's open Machine event follows only the start of a block. A load change does not move it.

Blocked work center. A Down dispatch blocks the work center from its createdAt until it is Completed or Cancelled. A Planned dispatch blocks it from actualStartTime while it is In Progress. The view workCentersWithBlockingStatus counts In Progress dispatches only. The engine uses the broader periods, because the MES ends every event on the work center when a user creates a Down dispatch. A supervisor dismisses the queued time as maintenance.

Steady state. After the changes, the engine checks one more case. The device is Running, currentStateAt > lastManualChangeAt, and nothing is open. Then the engine records the run up to now, by the owner rule. The start is the latest Machine endTime after currentStateAt, or currentStateAt when that is later. This rule covers a Machine event that a maintenance dispatch or End Shift closed during a run.

Time around a press.

  • Running past a press. The machine runs at a press and keeps running. The time after the press goes to the queue. If the machine stops within minimumStateSeconds of the press, the engine records nothing.
  • Two presses between syncs. The sync passes the earliest press since the last sync. If the machine ran through it, the time between the presses that nothing holds goes to the queue.
  • A late stop. A stop can arrive after a press and fall inside a queue row that the press ended. The engine cuts the row to the time the machine ran: it updates, splits or deletes the row. The engine never trims a Machine event. Queue rows do not post, so a trim is safe.

Short rows. Each sync deletes the closed unattributed rows on its work center that are shorter than minimumStateSeconds.

6. The MES Machine button (community)

The Machine timer stays visible. It shows the open Machine event, as it does today (useOperation treats an open Machine event as active for every operator). The MES operation page shows no device badge. The work center display shows the device state.

A machine has one machine time, and operators share it. The press rules apply on every work center, with or without a device:

  1. Start on operation C: end every open Machine event on the work center at the press time, from any operator or the sensor. Insert a Machine event on C that starts at the press time. The insert loads C.
  2. Pause: end every open Machine event on the work center at the press time. The operation stays loaded.

A press does not end an event that starts after the press time. On a work center with a device, the press also does 2 things:

  1. It ends the open unattributed row at the press time.
  2. It sets lastManualChangeAt to the later of its value and the press time. It sets unplannedPressAt to the earlier of its value and the press time. The sync clears unplannedPressAt.

Example: the machine is Active. The operator presses Pause at 10:03. Machine time on the operation stops at 10:03. If the machine runs on, the time after 10:03 goes to the queue until the machine stops.

Locks. A press takes its locks in one order:

  1. The workCenterDevice row FOR UPDATE (lockWorkCenterDevice). The sync takes this lock first too.
  2. A transaction advisory lock on the work center. It exists with or without a device.
  3. For an End only: the event row FOR UPDATE, while the event is open.

lockMachinePress (@carbon/database/machine-time) takes the first 2 locks. recordManualMachinePress reads the press time under them. So presses on one work center run one at a time, and the recorded press never moves backwards.

Start and End. startMachineProductionEvent (MES operations.service.ts) runs the press, the event insert and the tracked activity in one Kysely transaction. If one write fails, nothing ends. endMachineProductionEvent refuses an event that has already ended, and an event that starts after the press. The route then says "This event has already ended". The End route reads the event's own work center and type, not the form's values.

Permissions. The Kysely writes skip RLS. So event.tsx and start.$operationId.tsx check create or update on production before any write. event.tsx returns a flash message when it refuses.

Posting. The routes post every event that a press ends, except batch events (postEndedProductionEvents). The QR start with type=Machine follows rule 1. After the start, it ends the operation's Setup and Labor events and posts them.

7. The sync job

  1. The Inngest cron oee-sweep runs every 2 minutes. It selects active companyIntegration rows whose integration has providerRole = 'oee' and at least 1 workCenterDevice. It sends one carbon/oee-sync event per (company, integration). It copies ramp-sweep.ts.
  2. oee-sync runs with concurrency 1 per company and a singleton (skip) per company and integration. It syncs all devices of the integration inside one step.run. One step per device would multiply the Inngest cost by the device count.
  3. If the company is not entitled to INTEGRATIONS, the integration is inactive, or the key is empty, getOeeProvider returns an error. The job skips the integration.
  4. For each device, the job reads state changes from lastEventAt − 10 minutes to now. The overlap catches events that Sense stores late. The first sync reads from 24 hours before the mapping.
  5. The job inserts the changes into machineStateChange with ON CONFLICT DO NOTHING. The unique key is (workCenterDeviceId, externalEventId, companyId).
  6. The job opens one Kysely transaction per device. It locks the workCenterDevice row FOR UPDATE. The MES press takes the same lock first, so a press and a sync never interleave.
  7. The job reads the open Machine event, the open unattributed row, the latest Machine endTime and the stored changes. It computes the start of the window: the earliest instant this plan can touch. It reads the loads, the block periods and the recorded intervals inside the window.
  8. The job runs planMachineTime and applies the writes. A close matches only a row that is still open.
  9. The job deletes the closed unattributed rows on the work center that are shorter than minimumStateSeconds.
  10. In the same transaction, the job sets currentState, currentStateAt, appliedThrough, lastEventAt and lastSyncedAt. It clears unplannedPressAt and lastSyncError. lastEventAt follows the newest stored change, never the clock.
  11. If one device fails, the job writes lastSyncError on that device and keeps its cursor. The other devices continue. An OeeProviderUnavailableError (network failure, timeout, 5xx) stops the run, because every device would fail the same way.

A Machine event posts to the GL when it ends. After each device's transaction commits, the job posts the Machine events that its sync ended (postEndedMachineEvents, which invokes post-production-event). The other writers that end sensor time also post what they end: an assignment of unattributed time, an unmap or remap, the Sense uninstall, a press and a Down maintenance dispatch. A posting failure is logged and does not stop the sync. Operation finish (finishJobOperation, completeOperation) and job completion (complete_job_to_inventory) post any ended event that is still unposted. Carbon has no scheduled sweep that posts production events. A supervisor can still edit a posted event on the job's Events tab: the edit reverses the posted amount and posts the new one.

When a user uninstalls Sense, its onUninstall hook (senseOnUninstall) ends the open sensor time of every Sense device of the company. The mappings stay.

8. Unattributed machine time (ERP)

Production → Unattributed Time (x+/production+/machine-time.tsx). The nav item shows only while an OEE integration is active. The list copies the Batches list.

Column Value
Work center name
Location the work center's location
Start, End in the work center's location timezone
Duration endTime − startTime; "Running" while open
State "Running" (blue) or "Stopped" (green)

The list has 5 filters: work center, location, start date, end date and state. The date filters use the same timezone as the list (the view unattributedMachineTimes). The list has no sort.

unattributedMachineTime is a review queue, not a record. It has no status. A row leaves the queue in 3 ways:

  1. Assign: the action inserts a Machine productionEvent with the row's startTime and endTime, employeeId = null and createdBy = the user. Then it deletes the row. The event is the record.
  2. Not job time (dismiss): the action deletes the row. It takes no reason.
  3. pg_cron deletes the row 30 days after its endTime.

Assign and dismiss refuse a row that has no endTime: the machine is still running. Assign also refuses a Done or Canceled operation and a locked job. It checks them under row locks, inside its transaction.

The drawer (machine-time.$id.tsx) reviews the rows of the filtered list one at a time:

  • Suggestion cards show the operations that ran on the work center on the days the row covers, best match first. Keys 1 to 6 assign a card.
  • A search card lists the open operations at the work center's location, including operations with no work center.
  • "Not job time" dismisses the row. Skip, j and k move between rows.

Each answer moves to the next row. Closing the drawer returns to the list with its filters.

9. Out of scope for v1

Item Why not now
An MES prompt ("What's running on W1?") User decision (Q3). The ERP list comes first.
Splitting one unattributed row across 2 operations A run without a load is normally one job. The supervisor can edit the event on the job's Events tab.
An OEE availability or downtime report machineStateChange stores the data for it. The report is a later spec.
Telemetry, cycle counts, program numbers A current clip gives no program. Telemetry is not needed to attribute time.
Sense partner tokens (/v1/public/partners/…) Sense issues company-scoped keys to customers.
A pool work center with several devices The mapping is 1:1 (Q1).
Importing history from before the mapping No loaded operation exists for that period.

Design Decisions

Decision Choice Rationale
Provider cardinality Several OEE providers can be active at once. A work center has at most 1 device across all providers. User decision (Q1). Shops mix vendors. The single-active trigger skips the oee role. UNIQUE(workCenterId, companyId) on workCenterDevice holds the real rule.
Mapping cardinality 1 device ↔ 1 work center User decision (Q1). The scheduler treats a work center as capacity 1 (.claude/rules/scheduling-data-structures.md). A pool work center ("VF2 ×3") must be split into one work center per machine.
Mapping storage New table workCenterDevice, not externalIntegrationMapping The row also holds the cursor, the live state and lastManualChangeAt. The cross-provider unique rule is a plain UNIQUE here. In externalIntegrationMapping the unique key includes integration, so it cannot enforce it.
Attribution The loaded operation per work center. It is never the top of the schedule. Carbon never infers a job. User decision (Q2). Research: every vendor keeps an explicit active job per machine.
How an operation is loaded Any open productionEvent insert on the work center Setup, Labor, Machine and the QR start already insert one. Shops change nothing.
Unattributed time Its own table, cleared from an ERP list User decision (Q3). productionEvent.jobOperationId is NOT NULL, so unattributed time cannot be a production event.
Manual Machine timer Kept on every work center. A press ends every open Machine event on the work center. The time after a press in the same run goes to the queue. Pause keeps the operation loaded. User decision (Q4, Q4b, Q4c). A work center has one machine time, so time is never counted twice.
GL posting A sensor event posts when it ends: at the sync that ends it, at an assignment, an unmap or uninstall, or a press. Operation finish and job completion post what a failure left. There is no posting sweep. User decision (Q5, revised 2026-10-14). Machine cost reaches WIP in the period the machine ran, not when the operation finishes. A posted event stays editable: an edit reposts the difference.
License boundary Provider, sync, mapping and the unattributed list are commercial (packages/ee, .ee.tsx), gated by INTEGRATIONS. The loaded operation, the MES button rules and the display are AGPL. User decision (Q6). Matches every other integration.
Timezone Store UTC instants. Use the work center's location.timezone for local time. Warn on a site/location mismatch. User decision (Q7).
Polling Inngest cron every 2 minutes, 10-minute overlap, idempotent insert Sense has no webhooks. A 2-minute delay keeps the work center display useful. The overlap plus the unique key makes a re-read safe.
Debounce minimumStateSeconds, default 60 Research: MachineMetrics uses 60 s for micro-stops. Vendors use 30 s to 3 min.
Alert and Offline Both end machine time. Offline means "no data", not "down". Research: vendors treat a sensor gap as unknown, never as running.
Blocked work center Running time goes to the unattributed list Maintenance run time must not reach a job. The supervisor dismisses it as maintenance.
Backfill None. A mapping charges no time before the moment of the save. The first sync reads the 24 hours before the mapping only to learn the starting state.
Load storage The history table workCenterLoad. The open row is the load. A pointer column held the same fact twice. Clearing its timestamp on unload let a late event load a replaced operation (.ai/lessons.md).
Who gets each moment The owner rule (section 5) The same facts give the same result in any order of arrival.
Sync errors lastSyncError and lastSyncedAt on workCenterDevice, shown in the Devices tab accountingSyncOperation.direction allows only accounting directions. A per-device column is enough for v1.
Heuristic 1: multi-tenancy Every new table has companyId, composite PK ("id", "companyId") and id('prefix') .claude/rules/conventions-database.md
Heuristic 2: service shape Service functions take client first and return { data, error }. The ee write functions call requireEntitlement(client, companyId, "INTEGRATIONS") first. .claude/rules/conventions-services.md, .claude/rules/commercial-licensing.md
Heuristic 3: RLS workCenterDevice, machineStateChange, unattributedMachineTime and workCenterLoad are SELECT-only for company employees (packages/database/src/authz/manifest.ts). Every write goes through Kysely in the sync, the MES press, the Sense uninstall hook, an entitlement-gated ee function or an interceptor (.claude/rules/authz-manifest.md).
Heuristic 4: permissions Devices tab: settings_update. Unattributed list: production_view. Assign or dismiss: production_update. MES Machine start: production_create. MES Machine end: production_update. Same scopes as integration settings and job events. The MES routes check them because the Kysely writes skip RLS.
Heuristic 5: forms The drawer submits Assign and Dismiss with a fetcher. The route action validates them with zod validators in production.models.ts. .claude/rules/conventions-forms.md
Heuristic 6: module layout ERP UI in modules/production/ui/MachineTime/*.ee.tsx and modules/settings/ui/Integrations/OeeDevices.ee.tsx. Reads in production.service.ts. Writes in @carbon/ee/oee.server. One service and one models file per module. Gated writes live in packages/ee.
Heuristic 7: compatibility Additive, with one change for work centers with no device: a Machine press ends every open Machine event on the work center. No public contract changes.

Data Model Changes

erDiagram
    workCenter ||--o| workCenterDevice : "mapped to"
    workCenter ||--o{ workCenterLoad : "loads"
    workCenterLoad }o--|| jobOperation : "loaded operation (no FK)"
    workCenterDevice ||--o{ machineStateChange : "reports"
    workCenter ||--o{ unattributedMachineTime : "has"
    jobOperation ||--o{ productionEvent : "has"

The migrations, in order:

Migration Change
20261013030022_oee-provider.sql The role, the machineState enum and the three OEE tables
20261013170425_unattributed-time-queue.sql The queue drops its status columns
20261013191915, 20261013201722 Composite foreign keys to workCenter, and retention
20261013233811 The view unattributedMachineTimes
20261014010130_work-center-load-history.sql The table workCenterLoad
20261014024119_oee-load-is-history.sql Drops the pointer columns. Adds the constraints, unplannedPressAt and the sync's indexes
Table Columns and constraints
integration providerRole CHECK allows 'oee'. check_single_active_provider_role() returns early for oee. Row sense with providerRole = 'oee'.
workCenterDevice (id('wcd')) workCenterId, integration, externalDeviceId, externalSiteId, siteTimezone, deviceName, currentState (machineState), currentStateAt, appliedThrough, lastEventAt, lastManualChangeAt, unplannedPressAt, lastSyncedAt, lastSyncError, audit columns. UNIQUE (workCenterId, companyId), UNIQUE (integration, externalDeviceId, companyId). FK (workCenterId, companyId) → workCenter.
machineStateChange (id('msc')) workCenterDeviceId, workCenterId, externalEventId, state, changedAt. UNIQUE (workCenterDeviceId, externalEventId, companyId). FK (workCenterId, companyId) → workCenter. pg_cron deletes rows older than 30 days and rows of an unmapped device.
unattributedMachineTime (id('umt')) workCenterId, startTime, endTime, audit columns. No status. FK (workCenterId, companyId) → workCenter. pg_cron deletes rows 30 days after endTime.
workCenterLoad (id('wcl')) workCenterId, jobOperationId (no FK), loadedAt, unloadedAt, createdAt. CHECK unloadedAt IS NULL OR unloadedAt >= loadedAt. Partial unique index: one open row per work center. FK (workCenterId, companyId) → workCenter.

machineState is the enum 'Running', 'Idle', 'Down', 'Offline'. The view workCentersWithBlockingStatus exposes loadedJobOperationId from the open workCenterLoad row. Two indexes serve the sync: productionEvent (workCenterId, endTime) WHERE type = 'Machine' and maintenanceDispatch (workCenterId).

The migrations write no policies. The authz manifest renders them: the four OEE tables are SELECT-only for company employees. Every write goes through Kysely in the sync, the MES press, the Sense uninstall hook or an entitlement-gated @carbon/ee/oee.server function. The two interceptors are AFTER interceptors in packages/database/src/event-system/attachments.ts: sync_load_work_center_operation on productionEvent and sync_unload_work_center_operation on jobOperation. The dispatchers are SECURITY DEFINER, so the interceptors write workCenterLoad for an operator who has no resources_update permission. workCenterDevice and unattributedMachineTime have a statement broadcast (broadcast_table_changes). Backups remap workCenterLoad.jobOperationId and machineStateChange.workCenterDeviceId (packages/jobs/src/backups/id-refs.ts).

SECRET_KEYS (packages/ee/src/integrations/secrets.ts) gets sense: ["apiKey"]. The key stays at metadata.apiKey, as Linear's does, so the install path needs no credential fold. FORM_SECRET_INTEGRATIONS in integrations.$id.tsx gets "sense". Three unions get "oee": the descriptor type (packages/ee/src/types.ts), ProviderRole (packages/ee/src/index.ts) and ProviderRole (packages/ee/src/sync/topology.ts). The topology picks only the accounting and spend roles, so an oee row never enters it. The integration drawer hides Sync Activity for the oee role, and IntegrationCard does not treat an active oee integration as an incumbent.

API / Service Changes

Location Function Purpose
packages/ee/src/oee/types.ts OeeProvider, MachineState, OeeDevice, OeeStateChange The provider contract
packages/ee/src/oee/engine.ts planMachineTime Pure attribution rules (section 5). Unit-tested.
packages/ee/src/oee/assignable.ts machineTimeRefusal Can an operation take machine time
packages/ee/src/oee/service.server.ts getOeeProvider, upsertWorkCenterDevice, deleteWorkCenterDevice, assignUnattributedMachineTime, dismissUnattributedMachineTime The writes call requireEntitlement first.
packages/ee/src/sense/provider.ts SenseProvider The Sense adapter
packages/ee/src/sense/config.tsx, hooks.server.ts Sense descriptor, senseHealthcheck, senseOnUninstall Install, health and uninstall
packages/database/src/machine-time.ts lockWorkCenterDevice, lockMachinePress, recordManualMachinePress, endSensorMachineTime The locks and the writes that end machine time
packages/jobs/src/inngest/functions/integrations/oee-sweep.ts cron, every 2 minutes Sends carbon/oee-sync per company and integration
packages/jobs/src/inngest/functions/integrations/oee-sync.ts, oee-sync-device.ts oeeSyncFunction, syncOeeDevice Section 7
apps/erp/app/modules/production/production.service.ts getUnattributedMachineTimes, getUnattributedMachineTime, getUnattributedMachineTimeNeighbors, getWorkCenterDayEvents, getMachineTimeOperationCandidates Reads for the list and the drawer
apps/erp/app/modules/production/production.models.ts assignMachineTimeValidator, dismissMachineTimeValidator Form validators
apps/erp/app/modules/settings/oee-devices.server.ts getOeeDevicesTabData, saveWorkCenterDeviceMapping Devices tab loader and action
apps/mes/app/services/operations.service.ts startMachineProductionEvent, endMachineProductionEvent, postEndedProductionEvents Section 6
apps/mes/app/routes/x+/event.tsx, start.$operationId.tsx Machine start and end on every work center Section 6
apps/mes/app/services/display.service.ts getDisplayWorkCenter, getDisplayDeviceState Work-center display

Closest Sibling

Part Sibling Files copied
Provider class Accounting providers (providerRole: "accounting") packages/ee/src/accounting/core/types.ts (provider interface shape), packages/ee/src/index.ts (getIntegrationIdsByRole)
Descriptor and API-key settings Rillet packages/ee/src/rillet/config.tsx, rillet/hooks.server.ts
Role-targeted polling Ramp packages/jobs/src/inngest/functions/integrations/ramp-sweep.ts, ramp-sync.ts
Devices tab Account Mapping apps/erp/app/modules/settings/ui/Integrations/AccountMapping.tsx (row form, Combobox, per-row save). The row is flipped: the provider object is on the left and the Carbon record is the combobox.
Unattributed list Production → Batches apps/erp/app/routes/x+/production+/batches.tsx, modules/production/ui/Batches/BatchesTable.tsx
Assign drawer Job events apps/erp/app/routes/x+/job+/$jobId.events.new.tsx, ProductionEventForm

The feature deviates from its siblings in 3 places. Each one is a row in Design Decisions:

  1. The mapping lives in its own table, not externalIntegrationMapping.
  2. The oee role allows several active providers.
  3. Sync errors are columns on the device, not Sync Activity rows.

UI Changes

Surface Change Archetype
ERP Settings → Integrations → Sense New integration card. Drawer with Connection settings and a Devices tab. Integration drawer (same as Rillet)
ERP Production nav New item Unattributed Time in the Production group, after Batches. It shows only while an OEE integration is active. List page with a drawer (same as Batches)
ERP Production → Unattributed Time → row Review drawer: suggestion cards, a search card, "Not job time" and Skip Drawer
MES operation screen No change. The Machine toggle's dot already marks running time. Button rules in section 6. No new archetype
MES work-center display Loaded operation, and the device state when mapped Existing display
Docs docs/content/docs/integrations/oee.mdx, added to meta.json; a "Loaded operation" section in docs/content/docs/reference/work-centers.mdx Integration guide

If the company is not entitled to INTEGRATIONS, the Devices tab and the Unattributed Time page render the upgrade overlay (usePlanGate). The Unattributed Time nav item shows only while an OEE integration is active, so a company with no OEE integration does not see it.

Acceptance Criteria

  • With the staging API key, installing Sense shows a healthy connection. The Devices tab lists the 55 Sense stations with their site names.
  • Mapping Station 0002 to work center W1 saves a workCenterDevice row. The action refuses a second station on W1. Its message names Station 0002.
  • Mapping a station from site Reston - 2 (UTC) to a work center whose location is in America/New_York shows the timezone warning.
  • Activating Sense while another oee integration is active succeeds. The single-active trigger still refuses a second active accounting integration.
  • An operator starts Setup on operation A at W1 and stops it. The open workCenterLoad row of W1 names A.
  • An event that starts before the newest loadedAt or unloadedAt of W1 loads nothing.
  • Sense reports Active at T1 and Idle at T2 for the mapped station. Within 2 sync runs, a Machine productionEvent on A exists with startTime = T1, endTime = T2, employeeId null and postedToGL true.
  • That event has a Production Event journal. Its cost is (T2 − T1) × W1's machine rate plus overhead.
  • With nothing loaded on W1, an Active change creates an open unattributedMachineTime row. The row appears on Production → Unattributed Time.
  • Assigning a stopped row to operation B creates a Machine event on B with the row's start and end, posts it, and deletes the row.
  • Dismissing a stopped row deletes it, and no event exists. Dismissing a running row fails.
  • The machine is Active and the operator presses Pause at 10:03. The event ends at 10:03. The time after 10:03 until the machine stops goes to an unattributed row. The next Idle→Active change opens a new event on the same operation.
  • A sensor event runs on A, and the operator presses Machine Start on operation C. A's event ends at the press time. C's event starts at the press time. C is loaded.
  • A sensor event runs on A, and an operator starts Setup on operation B. The next sync ends A's event at B's loadedAt and opens an event on B at that instant.
  • Running the sync twice over the same window creates no duplicate machineStateChange, productionEvent or unattributedMachineTime rows.
  • A state that lasts 30 seconds with minimumStateSeconds = 60 creates no event and does not close an open one.
  • If Sense returns a status outside the allowlist, that station gets lastSyncError and keeps its cursor. Other stations still sync.
  • W1 has an In Progress maintenance dispatch with OEE impact Down. Running time on W1 creates an unattributed row, not an event on the loaded operation.
  • Operation A goes Done while the machine runs. The event ends at the unload, and the rest of the run becomes an unattributed row that starts at that time.
  • On a work center with no workCenterDevice, a Machine press ends every open Machine event on the work center and writes no device column.
  • Uninstalling Sense ends the open sensor events and unattributed rows of its devices. The workCenterDevice rows stay.
  • On a plan without INTEGRATIONS, the Devices tab and the list show the upgrade overlay. Calling assignUnattributedMachineTime throws EntitlementError.
  • planMachineTime has unit tests for every rule in section 5 and the press examples in section 6, including the same facts in different orders of arrival.

Risks

Risk Severity Mitigation
A stale loaded operation: nobody finishes or reloads it, so another job's run time goes to it Med The work center display shows the loaded operation. Any timer start on the right operation reloads. A supervisor can edit the event on the job's Events tab until the operation is finished.
The staging host is plain HTTP, so the API key travels unencrypted Med Production uses HTTPS. The Staging option says "testing only" in its description.
Sense rate limits and backfill behavior are not documented Med Verify with one curl before the job is wired into the cron (.ai/lessons.md → "A VERIFY-flagged provider endpoint in a cron loop is an outage"). The 10-minute overlap tolerates late events. Confirm the limits with Sense before launch.
Inngest cost of a 2-minute cron Low The sweep sends events only for companies with at least one mapped device.
sync_set_job_operation_in_progress reopens a Done operation on an open-event insert Low The engine opens an event only on an assignable operation, which is never Done or Canceled. Assign inserts a closed event and refuses a Done or Canceled operation.
A long Sensor Offline gap hides real run time Low Offline ends machine time. The Devices tab shows currentState = Offline and the time of the last sync.
An operator presses Machine Start while the machine is Idle. The event runs until the sensor reports the next change. Med This is the override the user chose (Q4c). The work center display shows the sensor's Idle state. The supervisor can edit the event until the operation is finished.
One work center models a pool of machines Low Out of scope. The mapping refuses a second device, and the docs say to split the work center.

Open Questions

HARD STOP: Do not proceed with implementation until these are answered.

  • Can a company have more than one OEE provider active at once? — Answer: Yes. A work center has at most one device across all providers.
  • How does Carbon pick the job operation for sensor run time? — Answer: The loaded operation per work center. The latest Setup, Labor or Machine start there sets it, and it survives clock-out. Run time with nothing loaded is unattributed. Never the top of the schedule. No inference from In Progress operations.
  • Where is unattributed time resolved in v1? — Answer: An ERP supervisor list only. Assign to a job operation, or dismiss. The MES prompt is later work. (Shipped: dismiss takes no reason and deletes the row.)
  • What happens to the manual MES Machine timer on a mapped work center? — Answer: It stays visible and in sync with the sensor. There is one Machine event at a time, so no duplicates.
  • What does the Machine button do when the sensor drives the timer? — Answer: It overrides the sensor for the operator's time. Pause keeps the operation loaded. (Shipped as the owner rule: the time after a press in the same run goes to the queue.)
  • When does sensor machine time post to the GL? — Answer: At operation finish or job completion. Revised 2026-10-14: when the event ends (section 7); operation finish and job completion are the catch-up.
  • Which parts are commercial? — Answer: The provider, the sync, the mapping and the unattributed list are in packages/ee, gated by INTEGRATIONS. The loaded operation and its MES display are AGPL.
  • Which timezone wins for local time? — Answer: The work center's location timezone. Store UTC. Warn when the Sense site timezone differs.

Changelog

  • 2026-10-14: Sensor time posts when it ends (Q5 revised). The sync, assign, unmap/remap, the Sense uninstall and a Down maintenance dispatch post the Machine events they end. post-production-event locks the event row, and complete_job_to_inventory locks the unposted events it posts (migration 20261014135003), so two callers never post one event twice.
  • 2026-10-14: Fixes from the strict self-review (.ai/plans/2026-10-14-oee-review-fixes.md). The open workCenterLoad row is the load: the migration drops workCenter.loadedJobOperationId and loadedAt. A load older than the newest boundary in the history writes nothing. An unload ends the open row at GREATEST(NOW(), loadedAt). The engine applies one owner rule to every piece of a run. Open sensor time follows its owner across load, block and press edges. A late stop trims the closed queue rows. A press takes its time under the locks and records unplannedPressAt. A Machine start writes the press, the event and the tracked activity in one transaction. The routes check permission before any write and post every event a press ends. Uninstalling Sense ends its open sensor time. The ERP review keeps the list filters and spans the days of the row.
  • 2026-10-13: Build changes. Unattributed time became a queue with no status. Maintenance blocks became periods. The load gained its history table, workCenterLoad. The OEE tables became read-only through the API, with composite foreign keys to workCenter. The MES press rules apply on every work center.
  • 2026-10-12: Planning pass. Corrected the secret path, the interceptor timing, the view recreation and the indexes. Added the engine's inputs, applied state (appliedThrough) and first-sync rules. The steady-state rule now reopens time on the loaded operation when the rules allow it.
  • 2026-10-12: Created. Research: .ai/research/oee-provider-integration.md. Prior thinking: the kyoto session of 2026-10-07 ("Current clip job identification").