MES ability enforcement per process

Status: Approved Date: 2026-10-22 Research: .ai/research/mes-ability-enforcement.md

TL;DR

  • Each process that requires an ability now says what MES does when an operator lacks it: Warn (default) or Block.
  • The choice sits on the process form, under "Requires Ability". It shows only while that toggle is on.
  • The toggle's description now names the ability, which is the process's own name.
  • Warn: MES shows a banner on the operation page. The operator can still start.
  • Block: MES shows the banner and refuses all production work on the operation: Start, Log completed, Scrap, Rework, Mark as Done, step records and material issue. The message names the training that grants the ability.
  • There is no company-wide setting. Today MES always blocks; after this change every process starts on Warn.

Overview diagram

flowchart LR
    A["Operator opens operation"] --> B{"Process requires ability<br/>and operator lacks it?"}
    B -- no --> S["Start works"]
    B -- yes --> C{"process.abilityPolicy"}:::new
    C -- warn --> W["Yellow banner, Start works"]:::new
    C -- block --> X["Red banner, Start refused"]
    classDef new stroke-dasharray:4 3

Problem

An operator gets an ability when they complete a training. The trigger grant_ability_on_training_completion writes the employeeAbility row.

MES checks the ability at Start with getOperationEligibility (apps/mes/app/services/operations.service.ts). That check always blocks. An admin cannot choose a softer mode, and some abilities need a block while others only need a warning. The operator also sees no warning before Start. The process form does not say which ability its toggle requires.

Goals

  1. Add a per-process mode: Warn or Block. The default is Warn.
  2. In Warn mode, show a warning and let the operator start.
  3. In Block mode, refuse all production work on the operation. Tell the operator how to get the ability.
  4. Show the warning before Start, on all three MES operation views.
  5. Name the ability in the "Requires Ability" description.

Non-goals

  • No company-wide setting.
  • No change to the ability data model, the training trigger, or expiry rules.
  • No change to the scheduler's operator eligibility (packages/planning).
  • No other UX changes to processes, abilities or trainings.

Design

Data model

Migration 20261022063357_process-ability-policy.sql:

CREATE TYPE "processAbilityPolicy" AS ENUM ('Warn', 'Block');
ALTER TABLE "process"
  ADD COLUMN IF NOT EXISTS "abilityPolicy" "processAbilityPolicy" NOT NULL DEFAULT 'Warn';

ERP and MES read the values and the type from the generated processAbilityPolicy enum.

The same migration drops and re-creates the processes view, so p.* picks up the column. The column is read only while requiresAbility is on.

ERP process form

Part Change
resources.models.ts Add processAbilityPolicies and abilityPolicy: z.enum(...).optional() to processValidator.
ProcessForm.tsx The name field is controlled. The "Requires Ability" description reads "Only employees with the {name} ability can be scheduled for and run this process".
ProcessForm.tsx AbilityPolicy renders a Select "If an operator isn't qualified": Warn / Block. It shows only while Requires Ability is on, like the batch type select.
processes.$processId.tsx, processes.new.tsx Initial value abilityPolicy (stored value, else Warn).

insertProcess / updateProcess spread the validated input, so they write the field with no change.

MES

  1. getAbilityShortfall returns what the operator lacks, or null. One embedded read gets the process and its ability. Then the qualification and the granting training are read in parallel. A shortfall carries policy, processName, expiredOn and trainingName.
  2. abilityBlockRefusal is the only check the routes call. It builds the English flash text when the policy is Block.
  3. abilityBlockRefusal returns the refusal text when the policy is Block. These routes call it before they write: event (Start), start.$operationId, end.$operationId (kanban complete scan), batch.$batchId.complete and batch.$batchId.record (one member is checked, because every member runs the batch's process), complete, finish, scrap, rework, record, record.$id.delete, issue, issue-tracked-entity (single operation), unconsume, entity+/…scrap, and the inspection sample, measurement, disposition and complete-passed routes.
  4. The operation view disables the same actions when the policy is Block. Pause, Maintenance, Quality Issue, Instructions and Chat stay enabled. Not guarded: steps.complete-all (a manager override), steps.inspection (an automatic sync) and a batch pick.
  5. x+/event.tsx redirects a full-page POST (Sec-Fetch-Mode: navigate, a press before the page hydrates) back to the referring page, keeping the flash.
  6. The three loaders (operation, assembly, inspection) pass the shortfall to the view as abilityWarning. The assembly and inspection views disable the same work, and skip their timer auto-start, when the policy is Block.
  7. AbilityWarning renders a warning Alert (Warn) or a destructive Alert (Block). Its copy uses Lingui.

The server flash text stays English. MES routes have no server-side translation today.

Design decisions

Decision Choice Why
Where the mode lives On process Some abilities need a block and others a warning. User answer.
Company-wide setting None The per-process mode replaces it. User answer.
Column type Enum processAbilityPolicy: Warn / Block One generated type for ERP and MES, with no casts. Same pattern as invoiceAutomation.
Default Warn The original request.
Ability name on the form In the toggle's description Minimal. User answer.
Field visibility Only while Requires Ability is on Same pattern as the batch type select.
Warn UX Banner on the page, no extra click User answer.
Views with the banner Operation, assembly and inspection All three post Start to x+/event.tsx.
Which training to name One Active training with grantsAbilityId = the ability The trigger grants the ability from that link.

Acceptance criteria

  1. An existing process has abilityPolicy = 'Warn' after the migration.
  2. An admin opens a process and turns on Requires Ability. The description names the process. The "If an operator isn't qualified" select appears with Warn selected. Turning the toggle off hides the select.
  3. The admin picks Block and saves. The value is Block after a reload.
  4. Process "Welding" requires an ability, with policy Warn. Operator A has no employeeAbility row for it and opens a Welding operation. A yellow banner names the ability and its training. Operator A presses Start. The timer starts.
  5. Same setup with policy Block. Operator A sees a red banner. Start, Log completed, Scrap, Rework, Mark as Done, Record and Issue Material are disabled. A direct POST to any guarded route is refused, and nothing is written.
  6. Same setup with policy Block. Operator A scans the operation's start QR code. MES redirects to the operation page with the error toast.
  7. Operator A's employeeAbility.expiresAt is yesterday. The banner says the qualification expired, with the date.
  8. Operator B has a valid employeeAbility row. No banner shows. Start works in both modes.
  9. The assembly and inspection views show the same banner as the operation view.

Open questions (resolved)

  • Existing companies already get a hard block. What default do they get? — Answer: Warn, as the request says.
  • How does an operator see the warning in Warn mode? — Answer: A banner on the operation page. Start needs no extra click.
  • Company setting or per process? — Answer: Per process, on the process form. No company setting.

Changelog

  • 2026-10-22: First draft with a company-wide setting in Production → Shop Floor.
  • 2026-10-22: Implemented with the company setting.
  • 2026-10-22: Thermo-nuclear review fixes: enum column, one shared check, getAbilityShortfall, Block gating and no auto-start in the assembly and inspection views.
  • 2026-10-22: Block covers all production work, not only Start. The event route recovers from a full-page POST.
  • 2026-10-22: Moved the mode onto the process and removed the company setting. Named the ability in the toggle's description.