Open-source manufacturing ERP, MES and QMS. Quoting, MRP, inventory, shop floor, quality and lot/serial traceability on one Postgres schema, with a REST API and MCP server. Self-host or use Carbon Cloud.
TypeScript ai-agentsbill-of-materialserpinventory-managementleanmanufacturingmanufacturing-execution-systemmcp-servermesmrpopen-source-erppostgresqlproduction-planningqmsquality-management-systemreact-routerself-hostedsupabasetraceabilitytypescript
// SPDX-License-Identifier: AGPL-3.0-only
// Carbon (github.com/crbnos/carbon). Modified or adapted versions of this file,
// including ports, remain AGPLv3; serving them over a network requires releasing their source.
import type {
GaugeSpec,
InspectionFeatureSpec,
InspectionSpec,
NonConformanceSpec,
NonConformanceWorkflowSpec,
QualityData,
QualityDocumentSpec,
RiskSpec
} from "../../types.ts";
// The new-issue form copies source, required actions and MRB from these templates onto the issue.
export const WORKFLOWS: NonConformanceWorkflowSpec[] = [
{
key: "supplier-escape",
name: "Supplier Escape — Flight Hardware",
description:
"A purchased flight part failed receiving inspection. Quarantine the lot, find the root cause with the supplier, and put their corrective action on record before MRB closes it out.",
priority: "High",
source: "External",
requiredActions: [
"Containment Action",
"Root Cause Analysis",
"Corrective Action"
],
mrb: true
},
{
key: "customer-return",
name: "Customer Complaint — Returned Unit",
description:
"A customer reported a failure on delivered hardware. Acknowledge within one business day, contain any sister units, and verify the fix before closing.",
priority: "Medium",
source: "External",
requiredActions: [
"Customer Communication",
"Containment Action",
"Verification"
]
},
{
key: "incoming-hold",
name: "Incoming Lot Hold",
description:
"An incoming lot failed a screening test. Hold the whole lot in quarantine until teardown decides its disposition.",
priority: "Medium",
source: "Internal",
requiredActions: ["Containment Action"]
}
];
export const NON_CONFORMANCES: NonConformanceSpec[] = [
{
ref: "ncr:eps",
name: "Power harness short detected at integration",
source: "Internal",
status: "In Progress",
openDateOffset: -296,
quantity: 1,
priority: "High",
// An issue raised on the floor is raised against the operation that produced
// it. Without this link the issue page's Associations card is empty.
jobOperation: { job: "job:in-progress" },
items: [{ item: "ISR4-AV", quantity: 1 }],
assignee: "self"
},
{
ref: "ncr:fastener",
name: "Hinge-block fastener torque below spec on arm station 3",
source: "Internal",
status: "Registered",
openDateOffset: -285,
quantity: 12,
priority: "Medium",
items: [{ item: "FST-M5-A286", quantity: 12 }]
},
{
ref: "ncr:tank-wall",
purchaseReturnLine: {
purchaseReturn: "tank-wall-rtv",
line: 1,
quantity: 1
},
name: "Carbon arm wall below minimum thickness, delamination at mid-span",
description:
"Receiving UT scan on the Sentry short delivery measured 1.12 mm wall at mid-span of one ARM-CF-30 against a 1.15 mm minimum, with a 6 mm delamination. Arm quarantined; MRB to decide return-to-vendor vs. use-as-is with a strength analysis.",
type: "Supplier Issue",
source: "External",
status: "In Progress",
openDateOffset: -78,
dueDateOffset: 14,
quantity: 1,
priority: "Critical",
supplier: "Sentry Propulsion Systems",
purchaseOrderLine: { po: "po:closed-short", item: "ARM-CF-30" },
inspection: "insp:tank",
items: [
{ item: "ARM-CF-30", quantity: 1, disposition: "Return to Supplier" },
{ item: "ARM-200", quantity: 1 }
],
assignee: "self",
workflow: "supplier-escape",
actionTasks: [
{
action: "Containment Action",
status: "Completed",
dueDateOffset: -76,
completedOffset: -77
},
{
action: "Root Cause Analysis",
status: "In Progress",
dueDateOffset: 7,
processes: ["UAS Integration"]
},
{ action: "Corrective Action", status: "Pending", dueDateOffset: 21 }
],
mrb: {
status: "In Progress",
dueDateOffset: 10,
reviewers: [
{ title: "Engineering", status: "Completed", completedOffset: -70 },
{ title: "Quality", status: "In Progress" }
]
}
},
{
ref: "ncr:txrx-tvac",
salesReturnLine: { salesReturn: "transponder", line: 1 },
name: "Customer-reported mesh radio spare drifts off channel at cold soak",
description:
"Northgate reported one of two RDO-MESH-2X2 spares drifting 40 kHz off channel during their -32 °C cold-soak pre-screen. Unit returned for evaluation; root cause traced to an unstaked TCXO shield lid.",
type: "Customer Complaint",
source: "External",
status: "Closed",
openDateOffset: -12,
dueDateOffset: 2,
closeDateOffset: -3,
quantity: 1,
priority: "Low",
customer: "Northgate Defense Systems",
salesOrderLine: "soline:novasat-spares:txrx",
items: [{ item: "RDO-MESH-2X2", quantity: 1, disposition: "Rework" }],
workflow: "customer-return",
actionTasks: [
{
action: "Customer Communication",
status: "Completed",
dueDateOffset: -11,
completedOffset: -11
},
{
action: "Containment Action",
status: "Completed",
dueDateOffset: -9,
completedOffset: -10
},
{
action: "Verification",
status: "Completed",
dueDateOffset: -4,
completedOffset: -4
}
]
},
{
ref: "ncr:bat-lot",
name: "Li-ion battery lot quarantined — capacity drift on incoming cycle test",
description:
"Lot LOT-BAT-2609 lost 3.8% capacity over the first 20 incoming cycles, outside the 2% screening limit. Lot placed on hold pending cell-level teardown.",
type: "Material Issue",
source: "Internal",
status: "Registered",
openDateOffset: -6,
dueDateOffset: 20,
quantity: 1,
priority: "Medium",
trackedEntity: "LOT-BAT-2609",
items: [{ item: "BAT-SMART-11AH", quantity: 1 }],
// Feeds the supplier-quality KPI's issue this month.
supplier: "Vanguard Electronics Supply",
workflow: "incoming-hold",
actionTasks: [
{ action: "Containment Action", status: "Pending", dueDateOffset: 2 }
]
}
];
// Lot of 2 at AQL 1.0 / level II → code letter A, n = 2.
const BARE_BOARD_PLAN = {
drawingNumber: "PCB-BARE-R3 Fab Dwg Rev C",
aql: 1.0,
features: [
{
label: "1",
description: "Board thickness over copper",
nominalValue: "1.60",
tolerancePlus: "0.16",
toleranceMinus: "0.16",
unit: "mm"
},
{
label: "2",
description: "Plated through-hole diameter, J1 connector pattern",
nominalValue: "1.00",
tolerancePlus: "0.05",
toleranceMinus: "0.05",
unit: "mm"
}
] satisfies InspectionFeatureSpec[]
};
export const INSPECTIONS: InspectionSpec[] = [
{
source: "Receipt",
ref: "insp:tank",
receipt: "receipt:short",
item: "ARM-CF-30",
drawingNumber: "ARM-CF-30 Rev C",
aql: 1.0,
features: [
{
label: "1",
description: "Hinge-pin bore diameter (reamed)",
nominalValue: "0.4050",
tolerancePlus: "0.0020",
toleranceMinus: "0.0020",
unit: "in"
},
{
label: "2",
description: "Wall thickness at mid-span (UT)",
nominalValue: "1.20",
tolerancePlus: "0.10",
toleranceMinus: "0.05",
unit: "mm"
}
],
status: "Partial",
dispositionOffset: -78,
notes:
"S/N 0417 accepted. S/N 0418 wall under minimum at mid-span with a delamination — quarantined and raised to MRB.",
samples: [
{
status: "Passed",
inspectedOffset: -79,
measurements: [
{ feature: "1", value: 0.4052 },
{ feature: "2", value: 1.22 }
]
},
{
status: "Failed",
inspectedOffset: -79,
measurements: [
{ feature: "1", value: 0.4049 },
{ feature: "2", value: 1.12 }
]
}
]
},
// 10 boards at AQL 1.0 → n = 3.
{
source: "Receipt",
ref: "insp:bare-boards",
receipt: "receipt:paid",
item: "PCB-BARE-R3",
...BARE_BOARD_PLAN,
status: "Passed",
dispositionOffset: -67,
notes: "Three boards measured; thickness and via sizes nominal.",
samples: [
{
status: "Passed",
inspectedOffset: -67,
measurements: [
{ feature: "1", value: 1.62 },
{ feature: "2", value: 1.01 }
]
},
{
status: "Passed",
inspectedOffset: -67,
measurements: [
{ feature: "1", value: 1.58 },
{ feature: "2", value: 0.99 }
]
},
{
status: "Passed",
inspectedOffset: -67,
measurements: [
{ feature: "1", value: 1.61 },
{ feature: "2", value: 1.02 }
]
}
]
},
{
source: "Receipt",
ref: "insp:bare-boards-queue",
receipt: "receipt:bare-boards",
item: "PCB-BARE-R3",
...BARE_BOARD_PLAN,
status: "Pending",
samples: []
},
{
source: "Job Operation",
ref: "insp:eps-fpt",
job: "floor-eps-pcb",
status: "In Progress",
notes: "Board 1 of 4 measured; boards 2–4 still curing.",
samples: [
{
status: "Passed",
inspectedOffset: -1,
measurements: [
{ feature: "1", value: 5.02 },
{ feature: "2", value: 2.05 }
]
}
]
}
];
export const QUALITY_DOCUMENTS: QualityDocumentSpec[] = [
{
name: "Flight Hardware Receiving Inspection",
version: 1,
status: "Archived",
description:
"Superseded receiving procedure for flight hardware — visual and certificate review only.",
steps: []
},
{
name: "Flight Hardware Receiving Inspection",
version: 2,
status: "Active",
description:
"Receiving procedure for flight hardware: certificates, NDAA and origin evidence, packaging and critical dimensions before stock-in.",
steps: [
{
name: "Certificate of conformance matches PO and drawing revision",
type: "Checkbox",
required: true
},
{
name: "NDAA compliance letter and country of origin on file",
type: "Checkbox",
required: true
},
{
name: "Packaging and ESD condition on arrival",
type: "List",
required: true,
listValues: [
"ESD-sealed, intact",
"ESD seal broken",
"Out of specification"
]
},
{
name: "Hinge-pin bore gauge engagement",
description: "Measured with the go plug gauge fully seated.",
type: "Measurement",
required: true,
unitOfMeasureCode: "INCH",
minValue: 0.4,
maxValue: 0.5
}
]
},
{
name: "ESD Control Plan (ANSI/ESD S20.20)",
version: 0,
status: "Draft",
description:
"Draft ESD control plan for the avionics integration cell — grounding, wrist-strap checks and packaging.",
steps: []
}
];
export const GAUGES: GaugeSpec[] = [
{
key: "gauge-blocks",
gaugeType: "Gauge Block",
description: "Grade K steel gauge block set, 81 pc — metrology lab master",
modelNumber: "GBS-81K",
serialNumber: "MB-22-0144",
role: "Master",
status: "Active",
calibrationIntervalInMonths: 12,
acquiredOffset: -700,
calibrations: [
{
dateOffset: -560,
result: "Pass",
temperature: 20,
humidity: 45,
measurementStandard: "ISO 3650, NIST-traceable interferometry"
},
{
dateOffset: -200,
result: "Pass",
temperature: 20,
humidity: 43,
measurementStandard: "ISO 3650, NIST-traceable interferometry"
}
]
},
{
key: "caliper",
gaugeType: "Caliper - Outside",
description: "150 mm digital caliper — new unit for the integration cell",
modelNumber: "DC-150",
serialNumber: "C24-88213",
role: "Standard",
status: "Active",
calibrationIntervalInMonths: 6,
acquiredOffset: -10,
calibrations: []
},
{
key: "micrometer",
gaugeType: "Micrometer - Outside",
description:
"0–25 mm outside micrometer — retired after failed calibration",
modelNumber: "OM-25",
serialNumber: "M19-40522",
role: "Standard",
status: "Inactive",
calibrationIntervalInMonths: 6,
acquiredOffset: -900,
calibrations: [
{ dateOffset: -400, result: "Pass", temperature: 20, humidity: 46 },
{
dateOffset: -220,
result: "Fail",
requiresAction: true,
requiresRepair: true,
temperature: 20,
humidity: 44,
notes: "Anvil faces worn — flatness 1.8 µm, limit 0.6 µm. Retired."
}
]
}
];
export const RISKS: RiskSpec[] = [
{
title: "Single-source carbon arm supplier quality",
description:
"Sentry is the only qualified source for ARM-CF-30 and has now shipped two escapes in one lot.",
type: "Risk",
status: "Mitigating",
severity: 5,
likelihood: 3,
source: "Supplier",
supplier: "Sentry Propulsion Systems"
},
{
title: "Export classification review on payload spares",
description:
"The Army office requested EO/IR gimbal spares that may fall under USML XII(c) — confirm the classification before shipment.",
type: "Risk",
status: "In Review",
severity: 4,
likelihood: 2,
source: "Customer",
customer: "Army Small UAS Program Office"
},
{
title: "Gen1 motor magnets fail the 2027 DFARS magnet rule",
description:
"MTR-4114-G1 stator magnets are Chinese-origin NdFeB. DFARS 252.225-7052 bars them from 1 Jan 2027, so Gen2 must replace Gen1 in every open build.",
type: "Risk",
status: "Open",
severity: 3,
likelihood: 3,
source: "Item",
item: "MTR-4114-G1"
},
{
title: "Environmental chamber availability for ISR4-AV acceptance",
description:
"The environmental chamber was double-booked for the acceptance window; slot confirmed with the outside test house.",
type: "Risk",
status: "Closed",
severity: 3,
likelihood: 2,
source: "Job",
job: "job:in-progress"
},
{
title: "Qualify a second PDB board fab to cut lead time",
description:
"A second IPC-6012 Class 3 fab could halve the 21-day PCB lead time — accepted into next year's plan.",
type: "Opportunity",
status: "Accepted",
severity: 2,
likelihood: 4,
source: "General"
}
];
export const defenseQuality: QualityData = {
workflows: WORKFLOWS,
nonConformances: NON_CONFORMANCES,
inspections: INSPECTIONS,
qualityDocuments: QUALITY_DOCUMENTS,
gauges: GAUGES,
risks: RISKS
};