Skip to content

graff — a fast agentic coding harness in Zig: multi-provider, MCP, workflows, DGM evolution loop, TS/Python SDKs

Python
3.5 KB
Raw Blame

0148. A mid-stream provider "internal error" is a transient 500, not overflow

Status: accepted 2026-09-21. Reverses the #1019 classification.

Context

xAI (grok-4.6 on the Responses wire) sometimes ends a streamed response with a type:error frame whose message is Internal error during token parsing. #1019 read that as the tokenizer rejecting an over-window prompt and put "during token parsing" in the overflow table, with a matching carve-out so the gateway-flake ladder would never retry it. The remedy was emergency-trim and resend.

The frame does not behave like an input-size rejection:

  • It arrives after the model has already streamed output text, on requests well under the advertised window. A rejection for size arrives before any output, with no partial answer.
  • Trim-and-resend hit the same error again; resending the same body sometimes succeeded. Both are the signature of a server-side fault, not a size limit.
  • The provider's own reference harness classifies a streamed error / response.failed as a retryable HTTP 500 with bounded backoff, discarding the partial output; "token parsing" is not in its context-length list.

Treating it as overflow had a second cost. applyOverflowRecovery pins the context meter to the window before it decides whether it can trim (#174), so the between-turn compaction still engages after a genuine rejection that returned no usage. On a misclassified frame in a small conversation there was nothing to trim, the pin stayed, and the next turn force-compacted a conversation that was nowhere near the window.

Decision

  • A streamed provider "internal error" that lands after output began is a transient server error. It rides the bounded transient ladder in agent_gateway_retry.zig (3 attempts, 1·2·4 s backoff), with partial text cleared and, on the WS arm, the socket already retired so the rebuild reconnects with full input. The user sees [provider error mid-response — retrying in Ns (i/3)]; the overloaded wording is kept for overloaded cases.
  • Overflow classification requires a size or length phrasing, or a structured overflow code. An "internal error" with neither is never overflow, whatever else the message says.
  • The context meter is pinned only on a real overflow rejection. The pin-first order in applyOverflowRecovery is unchanged: for a genuine overflow that cannot trim in-turn (a compaction summary request, a second overflow after one trim, nothing left to drop) the pin is what lets the outer compactOrRecover path recover, and existing tests hold it there. Removing the misclassification removes the stale pin.

Consequences

A transient mid-stream fault costs one to three resends of the same body instead of a destructive trim, and a repeat surfaces as the provider's own error text after the ladder is spent. A real xAI over-window rejection still classifies through "maximum prompt length". Tier 2 midstream-provider-error-retries-not-trims scripts the frame after text deltas and asserts a retry, a text event with the retry line (ACP renders it as agent_message_chunk; a bound TUI sink gets session_notice), no error event, no partial text in history, and no extra compaction call on the following turn. ACP has no replace/reset update, so a client that already painted the first stream will append the retry. If xAI ever returns this message for an oversized prompt before any output, add a size-bearing phrasing to the overflow table rather than reinstating this needle.