Skip to content

Run frontier MoE models on hardware you already own — pure C, zero deps, experts streamed from disk. Tiny engine, immense model. 🐦

C

fix(windows): make coli stop actually find the serve, and stop orphaning engines

JustVugg35349e1e01cd
diff --git a/c/coli b/c/coli
index 2ce41bd1..cafa4ae2 100755
--- a/c/coli
+++ b/c/coli
@@ -1370,6 +1370,36 @@ def cmd_serve(a):
try: os.unlink(serve_pidfile(a.port))
except OSError: pass
+def _pid_alive(pid):
+ """Is `pid` a live process?
+
+ `os.kill(pid, 0)` is the POSIX idiom, but on Windows os.kill() has no signal
+ semantics: for a pid this process did not spawn it raises
+ OSError [WinError 87] "The parameter is incorrect" instead of reporting
+ liveness. cmd_stop caught that as "not running", so `coli stop` printed
+ "nothing running" while the port was still LISTENING and ~5 GB of engines
+ were resident (#1049, reported with a reproduction on Windows 11 native).
+ On win32 ask the OS directly instead."""
+ if sys.platform != "win32":
+ try: os.kill(pid, 0); return True
+ except OSError: return False
+ import ctypes
+ from ctypes import wintypes
+ PROCESS_QUERY_LIMITED_INFORMATION, STILL_ACTIVE = 0x1000, 259
+ k32 = ctypes.WinDLL("kernel32", use_last_error=True)
+ k32.OpenProcess.restype = wintypes.HANDLE
+ handle = k32.OpenProcess(PROCESS_QUERY_LIMITED_INFORMATION, False, pid)
+ if not handle: return False
+ try:
+ code = wintypes.DWORD()
+ if not k32.GetExitCodeProcess(handle, ctypes.byref(code)): return False
+ # STILL_ACTIVE is also a legal exit code; a process that exited with 259
+ # reads as alive here. SIGTERM on a dead pid is harmless, so the failure
+ # mode is a redundant kill, never a missed one.
+ return code.value == STILL_ACTIVE
+ finally:
+ k32.CloseHandle(handle)
+
def cmd_stop(a):
"""Shut down a running `coli serve` AND its engine — one command, no pkill.
The engine re-execs itself for OMP tuning, so its process is named `exe`,
@@ -1382,7 +1412,7 @@ def cmd_stop(a):
pf=serve_pidfile(a.port)
try:
with open(pf) as f: pid=int(f.read().split()[0])
- os.kill(pid,0); targets[pid]=f"coli serve (pidfile, port {a.port})"
+ if _pid_alive(pid): targets[pid]=f"coli serve (pidfile, port {a.port})"
except (OSError,ValueError,IndexError): pass
try: proc_entries=os.listdir("/proc")
except OSError: proc_entries=[] # native Windows has no /proc; the pidfile still works
@@ -1408,7 +1438,11 @@ def cmd_stop(a):
except OSError: pass
time.sleep(2.0)
for pid in targets:
- try: os.kill(pid, signal.SIGKILL); print(f" {pid}: forced (SIGKILL)")
+ # signal.SIGKILL does not exist on win32 and AttributeError is not OSError,
+ # so the bare `except OSError` let it escape and abort the command AFTER
+ # the SIGTERMs above (#1049). Line 752 in this file already uses the
+ # getattr form; os.kill(SIGTERM) is TerminateProcess on Windows anyway.
+ try: os.kill(pid, getattr(signal, "SIGKILL", signal.SIGTERM)); print(f" {pid}: forced")
except OSError: pass # gia' morto: bene
try: os.unlink(pf)
except OSError: pass
diff --git a/c/openai_server.py b/c/openai_server.py
index d2fbce69..ea2c5548 100644
--- a/c/openai_server.py
+++ b/c/openai_server.py
@@ -1685,6 +1685,87 @@ def tune_child_env(env, arch):
return env
+def _win_kill_on_close_job(pid):
+ """Tie an engine process to this server's lifetime, on Windows.
+
+ The engine re-execs itself for OMP tuning, and the re-exec's parent exits
+ immediately -- so the surviving engine is orphaned at birth. It is not a
+ descendant of anything the launcher can walk to, and it is not the pid the
+ server recorded, so neither the pidfile nor a parent-child scan can reach
+ it. #1049 measured the consequence on Windows 11: 2,617 MB still resident
+ after a shutdown that reported success, accumulating one ghost per
+ serve/stop cycle. (Same failure that OOM'd a box on 2026-07-16 with two
+ 17+5 GB ghosts, where `pkill -x glm` matched nothing because the re-exec
+ renames itself.)
+
+ A Job Object with KILL_ON_JOB_CLOSE fixes it at the OS level rather than by
+ guessing pids: job membership is INHERITED by child processes, so the
+ re-exec stays inside the job, and when the last handle closes -- normal
+ exit, TerminateProcess, or a crash of this server -- Windows terminates
+ everything in it. Returns the handle, which the caller must keep alive for
+ as long as the engine should live; returns None on any failure, which
+ simply restores today's behaviour.
+ """
+ if sys.platform != "win32" or not pid:
+ return None
+ try:
+ import ctypes
+ from ctypes import wintypes
+
+ class IO_COUNTERS(ctypes.Structure):
+ _fields_ = [("ReadOperationCount", ctypes.c_ulonglong),
+ ("WriteOperationCount", ctypes.c_ulonglong),
+ ("OtherOperationCount", ctypes.c_ulonglong),
+ ("ReadTransferCount", ctypes.c_ulonglong),
+ ("WriteTransferCount", ctypes.c_ulonglong),
+ ("OtherTransferCount", ctypes.c_ulonglong)]
+
+ class JOBOBJECT_BASIC_LIMIT_INFORMATION(ctypes.Structure):
+ _fields_ = [("PerProcessUserTimeLimit", ctypes.c_longlong),
+ ("PerJobUserTimeLimit", ctypes.c_longlong),
+ ("LimitFlags", wintypes.DWORD),
+ ("MinimumWorkingSetSize", ctypes.c_size_t),
+ ("MaximumWorkingSetSize", ctypes.c_size_t),
+ ("ActiveProcessLimit", wintypes.DWORD),
+ ("Affinity", ctypes.POINTER(ctypes.c_ulong)),
+ ("PriorityClass", wintypes.DWORD),
+ ("SchedulingClass", wintypes.DWORD)]
+
+ class JOBOBJECT_EXTENDED_LIMIT_INFORMATION(ctypes.Structure):
+ _fields_ = [("BasicLimitInformation", JOBOBJECT_BASIC_LIMIT_INFORMATION),
+ ("IoInfo", IO_COUNTERS),
+ ("ProcessMemoryLimit", ctypes.c_size_t),
+ ("JobMemoryLimit", ctypes.c_size_t),
+ ("PeakProcessMemoryUsed", ctypes.c_size_t),
+ ("PeakJobMemoryUsed", ctypes.c_size_t)]
+
+ JobObjectExtendedLimitInformation = 9
+ JOB_OBJECT_LIMIT_KILL_ON_JOB_CLOSE = 0x00002000
+ PROCESS_SET_QUOTA, PROCESS_TERMINATE = 0x0100, 0x0001
+
+ k32 = ctypes.WinDLL("kernel32", use_last_error=True)
+ k32.CreateJobObjectW.restype = wintypes.HANDLE
+ k32.OpenProcess.restype = wintypes.HANDLE
+ job = k32.CreateJobObjectW(None, None)
+ if not job:
+ return None
+ info = JOBOBJECT_EXTENDED_LIMIT_INFORMATION()
+ info.BasicLimitInformation.LimitFlags = JOB_OBJECT_LIMIT_KILL_ON_JOB_CLOSE
+ if not k32.SetInformationJobObject(job, JobObjectExtendedLimitInformation,
+ ctypes.byref(info), ctypes.sizeof(info)):
+ k32.CloseHandle(job); return None
+ handle = k32.OpenProcess(PROCESS_SET_QUOTA | PROCESS_TERMINATE, False, pid)
+ if not handle:
+ k32.CloseHandle(job); return None
+ ok = k32.AssignProcessToJobObject(job, handle)
+ k32.CloseHandle(handle)
+ if not ok:
+ k32.CloseHandle(job); return None
+ return job
+ except Exception:
+ return None # never let process bookkeeping break starting the engine
+
+
class Engine:
# cap=None = "not explicitly set": a glm-arch model's engine resolves the
# 0 sentinel (8 historically, 1 on Metal+darwin+fast SSD -- colibri.c
@@ -1701,6 +1782,14 @@ class Engine:
[str(executable), str(cap_for_arch(arch, cap))], env=child_env,
stdin=subprocess.PIPE, stdout=subprocess.PIPE, bufsize=0,
)
+ # Keep the job handle on the instance: KILL_ON_JOB_CLOSE fires when the
+ # LAST handle closes, so this reference is what ties the engine (and the
+ # OMP re-exec that orphans itself) to the server's lifetime (#1049).
+ # Guarded so the non-Windows path never touches .pid -- the test suite
+ # drives this class with a fake process object that has none.
+ self._win_job = None
+ if sys.platform == "win32":
+ self._win_job = _win_kill_on_close_job(getattr(self.process, "pid", None))
self.write_lock = threading.Lock()
self.pending_lock = threading.Lock()
self.pending = {}
diff --git a/c/tests/test_stop_liveness.py b/c/tests/test_stop_liveness.py
new file mode 100644
index 00000000..6b80313a
--- /dev/null
+++ b/c/tests/test_stop_liveness.py
@@ -0,0 +1,79 @@
+"""#1049: `coli stop` must actually find a live serve, on every platform.
+
+The bug these cover: `os.kill(pid, 0)` is the POSIX liveness idiom, but on
+Windows os.kill() has no signal semantics and raises OSError [WinError 87] for
+a pid the caller did not spawn. cmd_stop swallowed that as "not running", so
+`coli stop` reported "nothing running" while the port was still LISTENING and
+~5 GB of engines were resident.
+"""
+import importlib.machinery, importlib.util, os, subprocess, sys, unittest
+
+HERE = os.path.dirname(os.path.abspath(__file__))
+COLI = os.path.join(os.path.dirname(HERE), "coli")
+
+
+def load_coli():
+ loader = importlib.machinery.SourceFileLoader("coli_mod", COLI)
+ spec = importlib.util.spec_from_loader("coli_mod", loader)
+ mod = importlib.util.module_from_spec(spec)
+ loader.exec_module(mod)
+ return mod
+
+
+class StopLivenessTest(unittest.TestCase):
+ def setUp(self):
+ self.coli = load_coli()
+
+ def test_probe_exists(self):
+ """cmd_stop must not use the raw POSIX idiom for liveness."""
+ self.assertTrue(hasattr(self.coli, "_pid_alive"))
+ src = open(COLI, encoding="utf-8").read()
+ stop = src[src.index("def cmd_stop("):]
+ stop = stop[:stop.index("\ndef ")]
+ self.assertNotIn("os.kill(pid,0)", stop)
+ self.assertIn("_pid_alive(pid)", stop)
+
+ def test_self_is_alive(self):
+ self.assertTrue(self.coli._pid_alive(os.getpid()))
+
+ def test_reaped_child_is_not_alive(self):
+ """A process we started and waited on must read as dead."""
+ p = subprocess.Popen([sys.executable, "-c", "pass"])
+ p.wait()
+ self.assertFalse(self.coli._pid_alive(p.pid))
+
+ def test_sigkill_lookup_is_guarded(self):
+ """signal.SIGKILL is absent on win32 and AttributeError is not OSError."""
+ src = open(COLI, encoding="utf-8").read()
+ stop = src[src.index("def cmd_stop("):]
+ stop = stop[:stop.index("\ndef ")]
+ # the *call* must not name it directly; the explanatory comment may.
+ self.assertNotIn("os.kill(pid, signal.SIGKILL)", stop)
+ self.assertIn('getattr(signal, "SIGKILL"', stop)
+
+
+class OrphanJobTest(unittest.TestCase):
+ """The engine re-execs for OMP tuning and orphans itself; a Job Object with
+ KILL_ON_JOB_CLOSE is what ties it to the server's lifetime on Windows."""
+
+ def test_engine_takes_a_job_handle(self):
+ src = open(os.path.join(os.path.dirname(HERE), "openai_server.py"),
+ encoding="utf-8").read()
+ self.assertIn("_win_kill_on_close_job", src)
+ self.assertIn("JOB_OBJECT_LIMIT_KILL_ON_JOB_CLOSE", src)
+ self.assertIn("_win_kill_on_close_job(getattr(self.process,", src)
+ # the non-Windows path must not even read .pid: the suite drives Engine
+ # with a fake process object that has none.
+ self.assertIn('if sys.platform == "win32":', src)
+
+ def test_helper_is_a_noop_off_windows(self):
+ sys.path.insert(0, os.path.dirname(HERE))
+ try:
+ import openai_server
+ self.assertIsNone(openai_server._win_kill_on_close_job(os.getpid()))
+ finally:
+ sys.path.pop(0)
+
+
+if __name__ == "__main__":
+ unittest.main()