Apache DataFusion SQL Query Engine
docs: Label `bloom_filter_on_read` as a reading config (#15933)
Nuno Fariab4b77e949d9f
diff --git a/datafusion/common/src/config.rs b/datafusion/common/src/config.rsindex e3f88994d9..08e9a0c453 100644--- a/datafusion/common/src/config.rs+++ b/datafusion/common/src/config.rs@@ -473,6 +473,9 @@ config_namespace! {/// nanosecond resolution.pub coerce_int96: Option<String>, transform = str::to_lowercase, default = None+ /// (reading) Use any available bloom filters when reading parquet files+ pub bloom_filter_on_read: bool, default = true+// The following options affect writing to parquet files// and map to parquet::file::properties::WriterProperties@@ -548,9 +551,6 @@ config_namespace! {/// default parquet writer settingpub encoding: Option<String>, transform = str::to_lowercase, default = None- /// (writing) Use any available bloom filters when reading parquet files- pub bloom_filter_on_read: bool, default = true-/// (writing) Write bloom filters for all columns when creating parquet filespub bloom_filter_on_write: bool, default = falsediff --git a/datafusion/sqllogictest/test_files/information_schema.slt b/datafusion/sqllogictest/test_files/information_schema.sltindex 4f0a46c725..c95dc25576 100644--- a/datafusion/sqllogictest/test_files/information_schema.slt+++ b/datafusion/sqllogictest/test_files/information_schema.slt@@ -339,7 +339,7 @@ datafusion.execution.parquet.allow_single_file_parallelism true (writing) Controdatafusion.execution.parquet.binary_as_string false (reading) If true, parquet reader will read columns of `Binary/LargeBinary` with `Utf8`, and `BinaryView` with `Utf8View`. Parquet files generated by some legacy writers do not correctly set the UTF8 flag for strings, causing string columns to be loaded as BLOB instead.datafusion.execution.parquet.bloom_filter_fpp NULL (writing) Sets bloom filter false positive probability. If NULL, uses default parquet writer settingdatafusion.execution.parquet.bloom_filter_ndv NULL (writing) Sets bloom filter number of distinct values. If NULL, uses default parquet writer setting-datafusion.execution.parquet.bloom_filter_on_read true (writing) Use any available bloom filters when reading parquet files+datafusion.execution.parquet.bloom_filter_on_read true (reading) Use any available bloom filters when reading parquet filesdatafusion.execution.parquet.bloom_filter_on_write false (writing) Write bloom filters for all columns when creating parquet filesdatafusion.execution.parquet.coerce_int96 NULL (reading) If true, parquet reader will read columns of physical type int96 as originating from a different resolution than nanosecond. This is useful for reading data from systems like Spark which stores microsecond resolution timestamps in an int96 allowing it to write values with a larger date range than 64-bit timestamps with nanosecond resolution.datafusion.execution.parquet.column_index_truncate_length 64 (writing) Sets column index truncate lengthdiff --git a/docs/source/user-guide/configs.md b/docs/source/user-guide/configs.mdindex ea174943c1..0e75903219 100644--- a/docs/source/user-guide/configs.md+++ b/docs/source/user-guide/configs.md@@ -59,6 +59,7 @@ Environment variables are read during `SessionConfig` initialisation so they mus| datafusion.execution.parquet.schema_force_view_types | true | (reading) If true, parquet reader will read columns of `Utf8/Utf8Large` with `Utf8View`, and `Binary/BinaryLarge` with `BinaryView`. || datafusion.execution.parquet.binary_as_string | false | (reading) If true, parquet reader will read columns of `Binary/LargeBinary` with `Utf8`, and `BinaryView` with `Utf8View`. Parquet files generated by some legacy writers do not correctly set the UTF8 flag for strings, causing string columns to be loaded as BLOB instead. || datafusion.execution.parquet.coerce_int96 | NULL | (reading) If true, parquet reader will read columns of physical type int96 as originating from a different resolution than nanosecond. This is useful for reading data from systems like Spark which stores microsecond resolution timestamps in an int96 allowing it to write values with a larger date range than 64-bit timestamps with nanosecond resolution. |+| datafusion.execution.parquet.bloom_filter_on_read | true | (reading) Use any available bloom filters when reading parquet files || datafusion.execution.parquet.data_pagesize_limit | 1048576 | (writing) Sets best effort maximum size of data page in bytes || datafusion.execution.parquet.write_batch_size | 1024 | (writing) Sets write_batch_size in bytes || datafusion.execution.parquet.writer_version | 1.0 | (writing) Sets parquet writer version valid values are "1.0" and "2.0" |@@ -74,7 +75,6 @@ Environment variables are read during `SessionConfig` initialisation so they mus| datafusion.execution.parquet.statistics_truncate_length | NULL | (writing) Sets statictics truncate length. If NULL, uses default parquet writer setting || datafusion.execution.parquet.data_page_row_count_limit | 20000 | (writing) Sets best effort maximum number of rows in data page || datafusion.execution.parquet.encoding | NULL | (writing) Sets default encoding for any column. Valid values are: plain, plain_dictionary, rle, bit_packed, delta_binary_packed, delta_length_byte_array, delta_byte_array, rle_dictionary, and byte_stream_split. These values are not case sensitive. If NULL, uses default parquet writer setting |-| datafusion.execution.parquet.bloom_filter_on_read | true | (writing) Use any available bloom filters when reading parquet files || datafusion.execution.parquet.bloom_filter_on_write | false | (writing) Write bloom filters for all columns when creating parquet files || datafusion.execution.parquet.bloom_filter_fpp | NULL | (writing) Sets bloom filter false positive probability. If NULL, uses default parquet writer setting || datafusion.execution.parquet.bloom_filter_ndv | NULL | (writing) Sets bloom filter number of distinct values. If NULL, uses default parquet writer setting |