25 MB lightweight cross-platform database client for 100+ databases, including MySQL, PostgreSQL, SQLite, Redis, MongoDB, DuckDB, SQL Server, and Dameng. Built-in AI, MCP Server, CLI, desktop and Docker. | 轻量级跨平台数据库管理工具,支持 MySQL、PostgreSQL、SQLite、Redis、MongoDB、达梦等 100+ 数据库,提供桌面端、Docker、CLI、内置 AI 助手和 MCP。
TypeScript aicliclickhousedatabasedatabase-clientdatabase-managementdockerguimcpmongodbmysqlpostgresqlredisrustsql-serversqlitetaurivue
fix(windows): add installer failure diagnostics and manual install entry
zipg732e081ee447
diff --git a/packages/app-tests/tableStructureEditorState.test.ts b/packages/app-tests/tableStructureEditorState.test.tsindex 2203ebf702..05fea34c6d 100644--- a/packages/app-tests/tableStructureEditorState.test.ts+++ b/packages/app-tests/tableStructureEditorState.test.ts@@ -119,7 +119,7 @@ test("creates editable column drafts from column metadata", () => {);});-test("preserves MySQL generated expressions in original column metadata", () => {+test("preserves MySQL generated expressions in editable and original column metadata", () => {const expression = "GENERATED ALWAYS AS (`price` * `quantity`) STORED";const [draft] = createColumnDrafts([diff --git a/scripts/windows-installer.integration.mjs b/scripts/windows-installer.integration.mjsindex 7f396de789..e1296043e5 100644--- a/scripts/windows-installer.integration.mjs+++ b/scripts/windows-installer.integration.mjs@@ -79,6 +79,7 @@ SectionEnd!macro NSIS_HOOK_PREINSTALLSystem::Call 'shell32::IsUserAnAdmin() i .r0'WriteINIStr "${report}" "installer" "admin" "$0"+ WriteINIStr "${report}" "installer" "elevation" "$DbxElevationCode"WriteINIStr "${report}" "installer" "cmdline" "$CMDLINE"WriteINIStr "${report}" "installer" "language" "$LANGUAGE"WriteINIStr "${report}" "installer" "update" "$UpdateMode"@@ -152,6 +153,7 @@ SectionEndconsole.log(output);assert.match(output,/\[driver\]\r?\nadmin=0/);assert.match(output,/\[installer\]\r?\nadmin=1/);+ assert.match(output,/elevation=2/);assert.match(output,/complete=1/);assert.match(output,/update=1/);assert.match(output,/passive=1/);@@ -169,6 +171,7 @@ SectionEndrun('installer',['/S','/UPDATE','/NS','/R','/ARGS','"writable update argument"',`/D=${writableTarget}`]);await waitFor(()=>fs.existsSync(report)&&fs.readFileSync(report,'utf8').includes('version=new'));const writableOutput=fs.readFileSync(report,'utf8');+ assert.match(writableOutput,/elevation=0/);console.log(writableOutput);assert.match(writableOutput,/\[installer\]\r?\nadmin=0/);assert.doesNotMatch(writableOutput,/\/DBX_ELEVATED/);diff --git a/scripts/windows-installer.test.mjs b/scripts/windows-installer.test.mjsindex 267ce5e056..024a0763e2 100644--- a/scripts/windows-installer.test.mjs+++ b/scripts/windows-installer.test.mjs@@ -5,14 +5,24 @@ import { tmpdir } from 'node:os'import path from 'node:path'import { test } from 'node:test'-const compiler = process.env.NSIS_MAKENSIS || path.join(process.env.LOCALAPPDATA || '', 'tauri', 'NSIS', 'makensis.exe')-const available = process.platform === 'win32' && existsSync(compiler)+const compiler = process.env.NSIS_MAKENSIS || (process.platform === 'win32'+ ? path.join(process.env.LOCALAPPDATA || '', 'tauri', 'NSIS', 'makensis.exe')+ : 'makensis')+let compilerAvailable = false+try {+ execFileSync(compiler, [process.platform === 'win32' ? '/VERSION' : '-VERSION'], { timeout: 5000 })+ compilerAvailable = true+} catch {}+const available = process.platform === 'win32' && compilerAvailable+const template = readFileSync(new URL('../src-tauri/windows/nsis/installer.nsi', import.meta.url), 'utf8')+const diagnosticVariables = template.match(/^Var Dbx.*$/gm).join('\n')+const diagnostics = template.slice(template.indexOf('AllowSkipFiles off'), template.indexOf('; Probe without truncating'))+const elevationInit = template.slice(template.indexOf('Function .onInit\n') + 'Function .onInit\n'.length, template.indexOf(' \u0024{GetOptions} $CMDLINE "/P" $PassiveMode'))+const languages = ['English', 'SimpChinese', 'TradChinese'].map(language => `!insertmacro MUI_LANGUAGE "${language}"`).join('\n')test('Windows installer access checks and elevation handoff', { skip: !available }, () => {const dir = mkdtempSync(path.join(tmpdir(), 'dbx installer test '))- const template = readFileSync(new URL('../src-tauri/windows/nsis/installer.nsi', import.meta.url), 'utf8')const helper = template.match(/Function DbxEnsureInstallAccess\r?\n[\s\S]*?FunctionEnd/)[0]- const elevationInit = template.slice(template.indexOf('Function .onInit\n') + 'Function .onInit\n'.length, template.indexOf(' \u0024{GetOptions} $CMDLINE "/P" $PassiveMode'))assert.ok(elevationInit.includes('/DBX_PROFILE='))const launch = `ExecShell "runas" "$EXEPATH" '/DBX_ELEVATED /DBX_PROFILE="$3" /DBX_LANG=$LANGUAGE $2 /D=$INSTDIR'`assert.ok(helper.includes(launch))@@ -29,19 +39,20 @@ test('Windows installer access checks and elevation handoff', { skip: !availableconst binary = path.join(destination, 'dbx.exe')writeFileSync(binary, 'original executable contents')const script = `Unicode true+XPStyle on!include MUI2.nsh!include FileFunc.nsh!define MAINBINARYNAME "dbx"+!define VERSION "1.0.1"Name "DBX access probe"OutFile "${exe}"RequestExecutionLevel userSilentInstall silent-Var DbxElevated+${diagnosticVariables}Var DbxTestCancelVar DbxTestHandle-!insertmacro MUI_LANGUAGE "English"-LangString dbxElevationFailed \u0024{LANG_ENGLISH} "Elevation cancelled"-LangString dbxElevationUserMismatch \u0024{LANG_ENGLISH} "Different user"+${languages}+${diagnostics}${fixtureHelper}Function .onInit${elevationInit}@@ -61,6 +72,9 @@ ${elevationInit}\u0024{IfNot} \u0024{Errors}StrCpy $DbxTestCancel 1\u0024{EndIf}+FunctionEnd+Section+ ; NSIS applies the selected language after .onInit returns.StrCpy $0 "register zero"StrCpy $1 "register one"StrCpy $2 "register two"@@ -69,10 +83,11 @@ ${elevationInit}WriteINIStr "$EXEDIR\\result.ini" "probe" "registers" "$0|$1|$2|$3"WriteINIStr "$EXEDIR\\result.ini" "probe" "destination" "$INSTDIR"WriteINIStr "$EXEDIR\\result.ini" "probe" "language" "$LANGUAGE"+ WriteINIStr "$EXEDIR\\result.ini" "probe" "elevation" "$DbxElevationCode"+ WriteINIStr "$EXEDIR\\result.ini" "probe" "fileError" "$DbxFileProbeError"+ WriteINIStr "$EXEDIR\\result.ini" "probe" "folderError" "$DbxDirectoryProbeError"SetErrorLevel 0Quit-FunctionEnd-SectionSectionEnd`const source = path.join(dir, 'probe.nsi')@@ -80,9 +95,9 @@ SectionEndtry {// Also compile the unmodified production launch instruction and init code.writeFileSync(source, script.replace(fixtureHelper, helper))- execFileSync(compiler, ['/V2', source], { encoding: 'utf8', timeout: 30_000 })+ execFileSync(compiler, ['/V2', '/INPUTCHARSET', 'UTF8', source], { encoding: 'utf8', timeout: 30_000 })writeFileSync(source, script)- execFileSync(compiler, ['/V2', source], { encoding: 'utf8', timeout: 30_000 })+ execFileSync(compiler, ['/V2', '/INPUTCHARSET', 'UTF8', source], { encoding: 'utf8', timeout: 30_000 })const run = (args, target = destination) => {rmSync(result, { force: true })let status = 0@@ -98,11 +113,16 @@ SectionEndassert.equal(writable.status, 0, writable.output)assert.match(writable.output, /register zero\|register one\|register two\|register three/)assert.doesNotMatch(writable.output, /handoff/)+ assert.match(writable.output, /elevation=0/)+ assert.match(writable.output, /fileError=0/)+ assert.match(writable.output, /folderError=0/)assert.equal(readFileSync(binary, 'utf8'), 'original executable contents')const locked = run(['/TEST_LOCK'])assert.equal(locked.status, 0)assert.doesNotMatch(locked.output, /handoff/)+ assert.match(locked.output, /fileError=32/)+ assert.match(locked.output, /folderError=0/)assert.equal(readFileSync(binary, 'utf8'), 'original executable contents')const nested = run([], path.join(destination, 'new', 'nested DBX'))@@ -132,6 +152,7 @@ SectionEndconst elevated = run(['/TEST_ELEVATED'])assert.equal(elevated.status, 0)assert.doesNotMatch(elevated.output, /handoff/)+ assert.match(elevated.output, /elevation=3/)assert.match(elevated.output, /register zero\|register one\|register two\|register three/)const wrongUser = run(['/DBX_ELEVATED', '/DBX_LANG=1033', '/DBX_PROFILE="different Windows account"'])@@ -149,3 +170,138 @@ SectionEndrmSync(dir, { recursive: true, force: true })}})++// Compile the actual diagnostic strings and write policy on any host with NSIS.+// On Windows also execute a locked-file extraction: it must stop before the+// completion marker, and its expanded dialog must contain usable diagnostics.+test('Installer write failure diagnostics compile', { skip: !compilerAvailable }, async (t) => {+ const dir = mkdtempSync(path.join(tmpdir(), 'dbx write failure '))+ const payload = path.join(dir, 'payload.txt')+ const source = path.join(dir, 'failure.nsi')+ const exe = path.join(dir, 'failure.exe')+ const target = path.join(dir, 'destination')+ const report = path.join(dir, 'result.ini')+ mkdirSync(target)+ writeFileSync(payload, 'new executable contents')+ // Simulate only the user's Manual installation selection and Explorer launch.+ // Keep the production extraction policy, dialog code and exit handler intact.+ const fixtureDiagnostics = diagnostics+ .replace('Function DbxShowWriteError', 'Function DbxShowWriteErrorActual')+ .replace(' Call DbxShowWriteError\n', ' Call DbxShowWriteError\n WriteINIStr "$EXEDIR\\result.ini" "trace" "action" "$DbxWriteFailureAction"\n')+ .replace(`ExecShell "open" "$WINDIR\\explorer.exe" '/select,"$EXEPATH"'`,+ `WriteINIStr "$EXEDIR\\result.ini" "manual" "args" '/select,"$EXEPATH"'`)+ const dialogSelection = `Function DbxShowWriteError+ \u0024{If} $TestManual = 1+ StrCpy $DbxWriteFailureAction \u0024{DBX_WRITE_MANUAL}+ \u0024{ElseIf} $TestRetry = 1+ StrCpy $TestRetry 0+ System::Call 'kernel32::CloseHandle(p $TestHandle)'+ StrCpy $DbxWriteFailureAction \u0024{DBX_WRITE_RETRY}+ \u0024{Else}+ Call DbxShowWriteErrorActual+ \u0024{EndIf}+FunctionEnd`+ const script = `Unicode true+XPStyle on+!include MUI2.nsh+!include FileFunc.nsh+!define VERSION "1.0.1"+!define MAINBINARYNAME "dbx"+Name "DBX required file write test"+OutFile "${exe}"+RequestExecutionLevel user+SilentInstall silent+${diagnosticVariables}+Var TestHandle+Var TestManual+Var TestRetry+${languages}+${fixtureDiagnostics}+${dialogSelection}+${template.match(/Function DbxEnsureInstallAccess\r?\n[\s\S]*?FunctionEnd/)[0]}+Function .onInit+${elevationInit}+ \u0024{GetOptions} $CMDLINE "/LANG=" $0+ StrCpy $LANGUAGE $0+ \u0024{GetOptions} $CMDLINE "/LOCK" $0+ \u0024{IfNot} \u0024{Errors}+ System::Call 'kernel32::CreateFileW(w "$INSTDIR\\dbx.exe", i 0x80000000, i 0, p 0, i 3, i 0, p 0) p .s'+ Pop $TestHandle+ \u0024{EndIf}+ \u0024{GetOptions} $CMDLINE "/MANUAL" $0+ \u0024{IfNot} \u0024{Errors}+ StrCpy $TestManual 1+ \u0024{EndIf}+ \u0024{GetOptions} $CMDLINE "/RETRY" $0+ \u0024{IfNot} \u0024{Errors}+ StrCpy $TestRetry 1+ \u0024{EndIf}+ Call DbxEnsureInstallAccess+ \u0024{GetOptions} $CMDLINE "/READONLY" $0+ \u0024{IfNot} \u0024{Errors}+ SetFileAttributes "$INSTDIR\\dbx.exe" READONLY+ \u0024{EndIf}+FunctionEnd+Section+ SetOutPath $INSTDIR+ ; NSIS applies the selected language after .onInit returns.+ Call DbxUpdateElevationStatus+ StrCpy $0 "$INSTDIR\\dbx.exe"+ WriteINIStr "$EXEDIR\\result.ini" "diagnostics" "dialog" "$(dbxFileWriteErrorNoIgnore)"+ !insertmacro DbxExtractFile "/oname=dbx.exe" "${payload}" "$INSTDIR\\dbx.exe"+ WriteINIStr "$EXEDIR\\result.ini" "install" "complete" "1"+SectionEnd+`+ try {+ writeFileSync(source, script)+ const flag = process.platform === 'win32' ? '/' : '-'+ const compilation = execFileSync(compiler, [`${flag}V2`, `${flag}INPUTCHARSET`, 'UTF8', source], { encoding: 'utf8', timeout: 30_000 })+ assert.doesNotMatch(compilation, /unknown variable|unknown constant|unknown identifier/i)+ await t.test('Windows locked-file extraction stops and reports diagnostics', { skip: !available }, () => {+ for (const [language, diagnosticLabel, instruction] of [+ ['1033', 'Diagnostic code:', 'Please run the installer as administrator.'],+ ['2052', '诊断码:', '请以管理员权限运行安装程序。'],+ ['1028', '診斷碼:', '請以系統管理員權限執行安裝程式。'],+ ]) {+ for (const action of ['writable', 'readonly', 'retry', 'cancel', 'manual']) {+ t.diagnostic(`Windows extraction: language=${language}, action=${action}`)+ const locked = ['retry', 'cancel', 'manual'].includes(action)+ writeFileSync(path.join(target, 'dbx.exe'), 'original executable contents')+ // Win32 INI writes otherwise use the runner's ANSI code page.+ writeFileSync(report, '\ufeff', 'utf16le')+ let exitCode = 0+ try {+ execFileSync(exe, ['/S', `/LANG=${language}`, ...(locked ? ['/LOCK'] : []), ...(action === 'manual' ? ['/MANUAL'] : []), ...(action === 'retry' ? ['/RETRY'] : []), ...(action === 'readonly' ? ['/READONLY'] : []), `/D=${target}`], { timeout: 15_000, windowsVerbatimArguments: true, argv0: `"${exe}"` })+ } catch (error) {+ if (typeof error.status !== 'number') {+ const diagnostic = existsSync(report) ? readFileSync(report, 'utf16le') : 'No fixture report'+ throw new Error(`language=${language}, action=${action}: ${error.message}\n${diagnostic}`, { cause: error })+ }+ exitCode = error.status+ }+ const output = readFileSync(report, 'utf16le')+ assert.doesNotMatch(output, /Installer:|安装包:|安裝套件:/)+ assert.ok(output.includes(target), output)+ assert.ok(output.includes(diagnosticLabel), output)+ assert.match(output, new RegExp(`A[01]-E[01]-F${locked ? 32 : 0}-D0`))+ assert.ok(output.includes(instruction), output)+ assert.ok(output.includes('1.0.1'), output)+ assert.doesNotMatch(output, /Program Files|\$Dbx|\$EXEPATH|\$INSTDIR/)+ if (action === 'cancel' || action === 'manual') {+ assert.equal(exitCode, 2, 'A failed required-file write must stop installation')+ assert.doesNotMatch(output, /complete=1/)+ if (action === 'manual') assert.ok(output.includes(`args=/select,"${exe}"`), output)+ else assert.doesNotMatch(output, /\[manual\]/)+ assert.equal(readFileSync(path.join(target, 'dbx.exe'), 'utf8'), 'original executable contents')+ } else {+ assert.equal(exitCode, 0)+ assert.match(output, /complete=1/)+ assert.equal(readFileSync(path.join(target, 'dbx.exe'), 'utf8'), 'new executable contents')+ }+ }+ }+ })+ } finally {+ rmSync(dir, { recursive: true, force: true })+ }+})diff --git a/src-tauri/windows/nsis/installer.nsi b/src-tauri/windows/nsis/installer.nsiindex 8b62ab4e71..d024ea66c2 100644--- a/src-tauri/windows/nsis/installer.nsi+++ b/src-tauri/windows/nsis/installer.nsi@@ -1,4 +1,5 @@Unicode true+XPStyle onManifestDPIAware trueManifestSupportedOS all; Add in `dpiAwareness` `PerMonitorV2` to manifest for Windows 10 1607+ (note this should not affect lower versions since they should be able to ignore this and pick up `dpiAware` `true` set by `ManifestDPIAware true`)@@ -96,6 +97,12 @@ Var NoShortcutModeVar WixModeVar OldMainBinaryNameVar DbxElevated+Var DbxIsAdmin+Var DbxElevationCode+Var DbxFileProbeError+Var DbxDirectoryProbeError+Var DbxFailedFile+Var DbxWriteFailureActionName "${PRODUCTNAME}"BrandingText "${COPYRIGHT}"@@ -499,18 +506,33 @@ FunctionEnd!include "{{this}}"{{/each}}-; Keep the standard write-error actions while explaining how to upgrade legacy-; installations restored from Program Files without changing the install mode.-LangString dbxFileWriteError ${LANG_ENGLISH} "Error opening file for writing:$\r$\n$\r$\n$0$\r$\n$\r$\nIf you are upgrading DBX installed under Program Files, abort this installation, right-click the installer, and select Run as administrator.$\r$\n$\r$\nClick Abort to stop the installation,$\r$\nRetry to try again, or$\r$\nIgnore to skip this file."-LangString dbxFileWriteErrorNoIgnore ${LANG_ENGLISH} "Error opening file for writing:$\r$\n$\r$\n$0$\r$\n$\r$\nIf you are upgrading DBX installed under Program Files, cancel this installation, right-click the installer, and select Run as administrator.$\r$\n$\r$\nClick Retry to try again, or$\r$\nCancel to stop the installation."-LangString dbxFileWriteError ${LANG_SIMPCHINESE} "无法打开要写入的文件:$\r$\n$\r$\n$0$\r$\n$\r$\n如果正在升级安装于 Program Files 的 DBX,请中止本次安装,然后右键单击安装程序并选择“以管理员身份运行”。$\r$\n$\r$\n单击“中止”停止安装,$\r$\n单击“重试”再次尝试,或$\r$\n单击“忽略”跳过此文件。"-LangString dbxFileWriteErrorNoIgnore ${LANG_SIMPCHINESE} "无法打开要写入的文件:$\r$\n$\r$\n$0$\r$\n$\r$\n如果正在升级安装于 Program Files 的 DBX,请取消本次安装,然后右键单击安装程序并选择“以管理员身份运行”。$\r$\n$\r$\n单击“重试”再次尝试,或$\r$\n单击“取消”停止安装。"-LangString dbxFileWriteError ${LANG_TRADCHINESE} "無法開啟要寫入的檔案:$\r$\n$\r$\n$0$\r$\n$\r$\n如果正在升級安裝於 Program Files 的 DBX,請中止本次安裝,然後以滑鼠右鍵按一下安裝程式並選擇「以系統管理員身分執行」。$\r$\n$\r$\n按一下「中止」以停止安裝,$\r$\n按一下「重試」以再次嘗試,或$\r$\n按一下「忽略」以略過此檔案。"-LangString dbxFileWriteErrorNoIgnore ${LANG_TRADCHINESE} "無法開啟要寫入的檔案:$\r$\n$\r$\n$0$\r$\n$\r$\n如果正在升級安裝於 Program Files 的 DBX,請取消本次安裝,然後以滑鼠右鍵按一下安裝程式並選擇「以系統管理員身分執行」。$\r$\n$\r$\n按一下「重試」以再次嘗試,或$\r$\n按一下「取消」以停止安裝。"+; Required application files must never be skipped after a write failure.+AllowSkipFiles off+!define DBX_WRITE_CANCEL 2+!define DBX_WRITE_RETRY 4+!define DBX_WRITE_MANUAL 1001+LangString dbxInstallDiagnostics ${LANG_ENGLISH} "Version: ${VERSION}$\r$\nDestination: $INSTDIR$\r$\nDiagnostic code: A$DbxIsAdmin-E$DbxElevationCode-F$DbxFileProbeError-D$DbxDirectoryProbeError"+LangString dbxInstallDiagnostics ${LANG_SIMPCHINESE} "版本:${VERSION}$\r$\n安装目录:$INSTDIR$\r$\n诊断码:A$DbxIsAdmin-E$DbxElevationCode-F$DbxFileProbeError-D$DbxDirectoryProbeError"+LangString dbxInstallDiagnostics ${LANG_TRADCHINESE} "版本:${VERSION}$\r$\n安裝目錄:$INSTDIR$\r$\n診斷碼:A$DbxIsAdmin-E$DbxElevationCode-F$DbxFileProbeError-D$DbxDirectoryProbeError"+LangString dbxFileWriteErrorNoIgnore ${LANG_ENGLISH} "Unable to write this file:$\r$\n$0$\r$\n$\r$\n$(dbxInstallDiagnostics)$\r$\n$\r$\nPlease run the installer as administrator."+LangString dbxFileWriteErrorNoIgnore ${LANG_SIMPCHINESE} "无法写入文件:$\r$\n$0$\r$\n$\r$\n$(dbxInstallDiagnostics)$\r$\n$\r$\n请以管理员权限运行安装程序。"+LangString dbxFileWriteErrorNoIgnore ${LANG_TRADCHINESE} "無法寫入檔案:$\r$\n$0$\r$\n$\r$\n$(dbxInstallDiagnostics)$\r$\n$\r$\n請以系統管理員權限執行安裝程式。"+LangString dbxFileWriteTitle ${LANG_ENGLISH} "Unable to write an installation file"+LangString dbxFileWriteTitle ${LANG_SIMPCHINESE} "无法写入安装文件"+LangString dbxFileWriteTitle ${LANG_TRADCHINESE} "無法寫入安裝檔案"+LangString dbxManualInstall ${LANG_ENGLISH} "Manual installation"+LangString dbxManualInstall ${LANG_SIMPCHINESE} "手动安装"+LangString dbxManualInstall ${LANG_TRADCHINESE} "手動安裝"+LangString dbxFileWriteError ${LANG_ENGLISH} "$DbxFailedFile$\r$\n$\r$\n$(dbxInstallDiagnostics)$\r$\n$\r$\nPlease run the installer as administrator."+LangString dbxFileWriteError ${LANG_SIMPCHINESE} "$DbxFailedFile$\r$\n$\r$\n$(dbxInstallDiagnostics)$\r$\n$\r$\n请以管理员权限运行安装程序。"+LangString dbxFileWriteError ${LANG_TRADCHINESE} "$DbxFailedFile$\r$\n$\r$\n$(dbxInstallDiagnostics)$\r$\n$\r$\n請以系統管理員權限執行安裝程式。"+LangString dbxManualInstallFallback ${LANG_ENGLISH} "Yes: open the installer folder and exit. No: retry. Cancel: stop installation."+LangString dbxManualInstallFallback ${LANG_SIMPCHINESE} "“是”:打开安装包目录并退出;“否”:重试;“取消”:停止安装。"+LangString dbxManualInstallFallback ${LANG_TRADCHINESE} "「是」:開啟安裝套件目錄並結束;「否」:重試;「取消」:停止安裝。"LangString dbxWin7InstallerRequired ${LANG_ENGLISH} "This installer does not support Windows 7 or Windows Server 2012 R2.$\r$\n$\r$\nPlease use the dedicated Windows 7 / Server 2012 R2 package instead.$\r$\n$\r$\nOpen the download now?"LangString dbxWin7InstallerRequired ${LANG_SIMPCHINESE} "此安装包不支持 Windows 7 或 Windows Server 2012 R2。$\r$\n$\r$\n请改用 Windows 7 / Server 2012 R2 专用包。$\r$\n$\r$\n是否立即打开下载地址?"LangString dbxWin7InstallerRequired ${LANG_TRADCHINESE} "此安裝套件不支援 Windows 7 或 Windows Server 2012 R2。$\r$\n$\r$\n請改用 Windows 7 / Server 2012 R2 專用套件。$\r$\n$\r$\n是否立即開啟下載網址?"-FileErrorText "$(dbxFileWriteError)" "$(dbxFileWriteErrorNoIgnore)"+FileErrorText "$(dbxFileWriteErrorNoIgnore)" "$(dbxFileWriteErrorNoIgnore)"LangString dbxElevationFailed ${LANG_ENGLISH} "Administrator permission is required to install DBX in this folder. Permission was denied or the elevated installer could not be started."LangString dbxElevationFailed ${LANG_SIMPCHINESE} "安装到此目录需要管理员权限。授权已被拒绝,或无法启动提权后的安装程序。"@@ -519,6 +541,119 @@ LangString dbxElevationUserMismatch ${LANG_ENGLISH} "Please approve elevation usLangString dbxElevationUserMismatch ${LANG_SIMPCHINESE} "请使用启动安装程序的同一个 Windows 账户授权提权,以确保 DBX 的安装信息和快捷方式保留在正确的用户配置中。"LangString dbxElevationUserMismatch ${LANG_TRADCHINESE} "請使用啟動安裝程式的同一個 Windows 帳戶授權提升權限,以確保 DBX 的安裝資訊和捷徑保留在正確的使用者設定中。"+Function DbxUpdateElevationStatus+ ; Compact support code: A=admin, E=elevation state, F/D=access prechecks.+ ; E: 0=not requested, 1=already admin, 2=elevated, 3=unconfirmed,+ ; 4=launch denied/failed, 5=profile mismatch. NA means not checked.+ System::Call 'shell32::IsUserAnAdmin() i .s'+ Pop $DbxIsAdmin+ ${If} $DbxElevated = 1+ ${If} $DbxIsAdmin != 0+ StrCpy $DbxElevationCode 2+ ${Else}+ StrCpy $DbxElevationCode 3+ ${EndIf}+ ${ElseIf} $DbxIsAdmin != 0+ StrCpy $DbxElevationCode 1+ ${Else}+ StrCpy $DbxElevationCode 0+ ${EndIf}+FunctionEnd++; Keep extraction failures under our control so a third action can open the+; installer folder without ever continuing past a failed required-file write.+!macro DbxExtractFile OPTIONS SOURCE DESTINATION+ StrCpy $DbxFailedFile "${DESTINATION}"+ Call DbxUpdateElevationStatus+ ${Do}+ Call DbxPrepareFileWrite+ SetOverwrite try+ ClearErrors+ File ${OPTIONS} "${SOURCE}"+ SetOverwrite on+ ${IfNot} ${Errors}+ ${ExitDo}+ ${EndIf}+ Call DbxShowWriteError+ ${If} $DbxWriteFailureAction = ${DBX_WRITE_RETRY}+ ${Continue}+ ${ElseIf} $DbxWriteFailureAction = ${DBX_WRITE_MANUAL}+ Call DbxManualInstall+ ${EndIf}+ SetErrorLevel 2+ Quit+ ${Loop}+!macroend++Function DbxPrepareFileWrite+ Push $0+ Push $1+ ; Preserve SetOverwrite on's handling of read-only files when using try to+ ; capture errors. Keep every other existing file attribute intact.+ System::Call 'kernel32::GetFileAttributesW(w "$DbxFailedFile") i .r0'+ ${If} $0 != -1+ IntOp $1 $0 & 1+ ${If} $1 != 0+ IntOp $0 $0 & 0xFFFFFFFE+ System::Call 'kernel32::SetFileAttributesW(w "$DbxFailedFile", i r0)'+ ${EndIf}+ ${EndIf}+ Pop $1+ Pop $0+FunctionEnd++Function DbxShowWriteError+ Push $0+ Push $1+ Push $2+ Push $3+ StrCpy $DbxWriteFailureAction ${DBX_WRITE_CANCEL}+ ; Unattended failures stop installation without opening Explorer or a dialog.+ ${If} ${Silent}+ Goto dbx_write_dialog_done+ ${EndIf}++ ; NSIS uses a 32-bit stub even for x64/arm64 application payloads.+ ; TASKDIALOGCONFIG is 96 bytes; use the Windows Retry/Cancel buttons plus+ ; a localized custom Manual installation button. Cancel is the default.+ ; Size to content so the default narrow layout does not shorten diagnostic paths.+ System::Call '*(i ${DBX_WRITE_MANUAL}, w "$(dbxManualInstall)") p .r1'+ System::Call '*(i 96, p $HWNDPARENT, p 0, i 0x1001008, i 0x18, w "$(^Name)", p 65534, w "$(dbxFileWriteTitle)", w "$(dbxFileWriteError)", i 1, p r1, i 2, i 0, p 0, i 0, p 0, p 0, p 0, p 0, p 0, p 0, p 0, p 0, i 0) p .r0'+ StrCpy $3 -1+ System::Call 'comctl32::TaskDialogIndirect(p r0, *i .r2, p 0, p 0) i .r3'+ System::Free $0+ System::Free $1+ ${If} $3 = 0+ StrCpy $DbxWriteFailureAction $2+ ${Else}+ ; A safe fallback if the system cannot create a task dialog.+ MessageBox MB_YESNOCANCEL|MB_ICONSTOP|MB_DEFBUTTON3 "$(dbxFileWriteError)$\r$\n$\r$\n$(dbxManualInstallFallback)" /SD IDCANCEL IDYES dbx_write_manual IDNO dbx_write_retry+ Goto dbx_write_dialog_done+ dbx_write_manual:+ StrCpy $DbxWriteFailureAction ${DBX_WRITE_MANUAL}+ Goto dbx_write_dialog_done+ dbx_write_retry:+ StrCpy $DbxWriteFailureAction ${DBX_WRITE_RETRY}+ ${EndIf}++ dbx_write_dialog_done:+ Pop $3+ Pop $2+ Pop $1+ Pop $0+FunctionEnd++Function DbxManualInstall+ ClearErrors+ ExecShell "open" "$WINDIR\explorer.exe" '/select,"$EXEPATH"'+ ${If} ${Errors}+ ExecShell "open" "$EXEDIR"+ ${EndIf}+ ; This is a failed installation, never a successful update or a skipped file.+ SetErrorLevel 2+ Quit+FunctionEnd+; Probe without truncating the old executable. Only ACCESS_DENIED requests UAC;; sharing violations still go through CheckIfAppIsRunning and normal retry UI.Function DbxEnsureInstallAccess@@ -526,10 +661,15 @@ Function DbxEnsureInstallAccessPush $1Push $2Push $3+ Call DbxUpdateElevationStatus+ StrCpy $DbxFileProbeError "NA"+ StrCpy $DbxDirectoryProbeError "NA"${If} ${FileExists} "$INSTDIR\${MAINBINARYNAME}.exe"System::Call 'kernel32::CreateFileW(w "$INSTDIR\${MAINBINARYNAME}.exe", i 0x40000000, i 7, p 0, i 3, i 0, p 0) p .r0 ?e'Pop $1+ StrCpy $DbxFileProbeError $1${If} $0 != -1+ StrCpy $DbxFileProbeError 0System::Call 'kernel32::CloseHandle(p r0)'${ElseIf} $1 = 5Goto dbx_elevate@@ -550,7 +690,9 @@ Function DbxEnsureInstallAccess${EndIf}System::Call 'kernel32::GetTempFileNameW(w r2, w "dbx", i 0, w .r3) i .r0 ?e'Pop $1+ StrCpy $DbxDirectoryProbeError $1${If} $0 != 0+ StrCpy $DbxDirectoryProbeError 0Delete "$3"${ElseIf} $1 = 5Goto dbx_elevate@@ -571,7 +713,8 @@ Function DbxEnsureInstallAccessClearErrorsExecShell "runas" "$EXEPATH" '/DBX_ELEVATED /DBX_PROFILE="$3" /DBX_LANG=$LANGUAGE $2 /D=$INSTDIR'${If} ${Errors}- MessageBox MB_OK|MB_ICONSTOP "$(dbxElevationFailed)" /SD IDOK+ StrCpy $DbxElevationCode 4+ MessageBox MB_OK|MB_ICONSTOP "$(dbxElevationFailed)$\r$\n$\r$\n$(dbxInstallDiagnostics)" /SD IDOKSetErrorLevel 740Pop $3Pop $2@@ -599,7 +742,11 @@ Function .onInit; entered in the UAC credential dialog.${GetOptions} $CMDLINE "/DBX_PROFILE=" $0${If} $0 != $PROFILE- MessageBox MB_OK|MB_ICONSTOP "$(dbxElevationUserMismatch)" /SD IDOK+ StrCpy $DbxFileProbeError "NA"+ StrCpy $DbxDirectoryProbeError "NA"+ Call DbxUpdateElevationStatus+ StrCpy $DbxElevationCode 5+ MessageBox MB_OK|MB_ICONSTOP "$(dbxElevationUserMismatch)$\r$\n$\r$\n$(dbxInstallDiagnostics)" /SD IDOKSetErrorLevel 740Quit${EndIf}@@ -705,7 +852,7 @@ Section WebView2; installer so an existing stale runtime is upgraded without network access.!if "${INSTALLWEBVIEW2MODE}" == "offlineInstaller"Delete "$TEMP\MicrosoftEdgeWebView2RuntimeInstaller.exe"- File "/oname=$TEMP\MicrosoftEdgeWebView2RuntimeInstaller.exe" "${WEBVIEW2INSTALLERPATH}"+ !insertmacro DbxExtractFile '"/oname=$TEMP\MicrosoftEdgeWebView2RuntimeInstaller.exe"' "${WEBVIEW2INSTALLERPATH}" "$TEMP\MicrosoftEdgeWebView2RuntimeInstaller.exe"DetailPrint "$(installingWebview2)"ExecWait '"$TEMP\MicrosoftEdgeWebView2RuntimeInstaller.exe" ${WEBVIEW2INSTALLERARGS} /install' $1Delete "$TEMP\MicrosoftEdgeWebView2RuntimeInstaller.exe"@@ -754,7 +901,7 @@ Section WebView2!if "${INSTALLWEBVIEW2MODE}" == "embedBootstrapper"Delete "$TEMP\MicrosoftEdgeWebview2Setup.exe"- File "/oname=$TEMP\MicrosoftEdgeWebview2Setup.exe" "${WEBVIEW2BOOTSTRAPPERPATH}"+ !insertmacro DbxExtractFile '"/oname=$TEMP\MicrosoftEdgeWebview2Setup.exe"' "${WEBVIEW2BOOTSTRAPPERPATH}" "$TEMP\MicrosoftEdgeWebview2Setup.exe"DetailPrint "$(installingWebview2)"StrCpy $6 "$TEMP\MicrosoftEdgeWebview2Setup.exe"Goto install_webview2@@ -815,22 +962,25 @@ Section Install!insertmacro CheckIfAppIsRunning "${MAINBINARYNAME}.exe" "${PRODUCTNAME}"+ Call DbxUpdateElevationStatus+ DetailPrint "$(dbxInstallDiagnostics)"+; Copy main executable- File "${MAINBINARYSRCPATH}"+ !insertmacro DbxExtractFile "" "${MAINBINARYSRCPATH}" "$INSTDIR\${MAINBINARYNAME}.exe"; MSVC links WebView2Loader statically, while GNU builds may emit a DLL next to the binary.- File /nonfatal /a "/oname=WebView2Loader.dll" "${WEBVIEW2LOADERSRCPATH}"+ !insertmacro DbxExtractFile "/nonfatal /a /oname=WebView2Loader.dll" "${WEBVIEW2LOADERSRCPATH}" "$INSTDIR\WebView2Loader.dll"; Copy resources{{#each resources_dirs}}CreateDirectory "$INSTDIR\\{{this}}"{{/each}}{{#each resources}}- File /a "/oname={{this.[1]}}" "{{no-escape @key}}"+ !insertmacro DbxExtractFile '/a "/oname={{this.[1]}}"' "{{no-escape @key}}" "$INSTDIR\{{this.[1]}}"{{/each}}; Copy external binaries{{#each binaries}}- File /a "/oname={{this}}" "{{no-escape @key}}"+ !insertmacro DbxExtractFile '/a "/oname={{this}}"' "{{no-escape @key}}" "$INSTDIR\{{this}}"{{/each}}; Create file associations