Skip to content

The first exam for code agents in the physical world: frozen robot tasks from many benchmark suites, each answered with a program and verified in a separate sandbox. Runs on Harbor.

2.8 KB
Raw Blame
Assemble the cross brace of a pine stool dry frame. The lower side frame lies flat on the table with its four bores facing up and three rails already standing seated in three of them. The loose cross brace (a 0.26 m pine rail with an 8 mm dowel exposed 15 mm at each end) lies on the table, and the opposite side frame lies upside down beside the lower frame. Pick up the brace, seat one of its dowels in the empty bore of the lower frame, then lift the opposite side frame and lower it onto all four upper dowels so that both brace dowels end up seated in their legs. Ordered stages: (1) brace lifted: no brace-table contact, brace centre raised at least 0.05 m and its lowest bounding-box corner at least 0.02 m above the table top; (2) one brace dowel seated in a lower-frame bore; (3) opposite side frame lifted (the same lift test); (4) assembled: each of the eight bores holds exactly one seated dowel and every rail, the brace included, has one dowel seated in each side frame. A dowel is seated in a bore when its tip is 12 mm to 19 mm past the bore entry along the bore axis (12 mm is 80% of the exposed dowel), its tip is within 1.6 mm of the bore axis and the dowel axis is within 0.105 rad of the bore axis. Success: after stage 4 the assembled condition holds with no hand contact on any frame or rail and every part's centre-of-mass speed at most 0.02 m/s and angular speed at most 0.2 rad/s for 50 consecutive controls (1 s); the episode then ends. A single seated brace dowel or any partial assembly never counts. The episode ends immediately with failure, checked after every 2 ms physics substep, when the lower frame moves more than 0.03 m or tilts more than 10 degrees; a pre-seated rail is pulled to less than 8 mm in its bore or tilts more than 10 degrees; the brace touches the table after stage 1, or its centre drops below 0.09 m above the table top after stage 1; the brace tilts more than 20 degrees after stage 2; the opposite side frame touches the table after stage 3 or tilts more than 20 degrees from its upside-down carrying orientation after stage 3; any part with no contact at all (not held, not supported) has its centre of mass falling faster than 0.2 m/s (a drop); any part touches the floor, has its centre below the table top (z < 0.74 m) or leaves the workspace box x in [0.23, 1.23] m, y in [-0.73, 1.03] m, z in [0.70, 1.60] m; or the physics becomes unstable. Later actions cannot undo a failure. Only robot actuator targets are allowed: no object teleports, grasp welds, scripted object motion or direct object forces. All parts are free rigid pine bodies; the bores are hollow contact geometry of the source size (4.1 mm radius for the 4.0 mm dowels: 0.1 mm radial clearance, no entry chamfer); glue, screws, the seat and load capacity are not modelled. The episode allows at most 6000 controls at 50 Hz; reaching that limit without success is a failure.