The first exam for code agents in the physical world: frozen robot tasks from many benchmark suites, each answered with a program and verified in a separate sandbox. Runs on Harbor.
Python ai-agentsbenchmarkcoding-agentsembodied-aievaluationharborllm-agentsrobot-learningroboticssimulation
{
"preset": "puzzle.syringe.bimanual_franka.osc",
"grader": "grader/syringe_dosing.py",
"title": "Draw and dose liquid with a syringe (two Frankas, operational-space control)",
"text": "On the top shelf of a medical cart: a large syringe LYING FLAT (a scanned model — translucent barrel with graduation marks and finger flanges, a plunger with a thumb plate, travel 0.12 m = its full capacity, and a luer nozzle at the tip), a rack of three GLASS TEST TUBES, and a wide RESERVOIR beaker of water (its blue level visibly drops as liquid is drawn). The cart's lower shelf holds packaged syringes and a basin — scenery only.\nLiquid moves with the plunger, but ONLY while the syringe is roughly upright with the nozzle tip seated on a mouth: hovering within 6 mm laterally and 12 mm above the rim. Pulling the plunger while seated on the reservoir draws liquid; pushing it dispenses into whichever tube the tip is seated on — anywhere else the liquid is WASTED. Tubes never un-fill: a tube pushed past its band is ruined for the episode (the reservoir can be re-drawn from, but over-dispensing cannot be undone). The water is VISIBLE: a blue column inside the translucent barrel shows the drawn liquid, and each tube fills with a blue column as it receives its dose. The plunger has deliberate friction: push/pull it slowly and steadily.\nGoal: draw a full load (>= 95% of capacity, tip seated in the reservoir), dispense between 23% and 43% of capacity into EACH of the three tubes, then lay the syringe back down at its spot on the shelf.",
"success": "Success, exactly: (1) at some moment the barrel held at least 95% of capacity (liquid gained only from plunger draw while the tip was seated on the reservoir) while the tip was seated on the reservoir beaker; (2) each of the three test tubes has received between 23% and 43% of capacity (0.12 m stroke), counting only plunger pushes made while the tip was seated on that tube's mouth; (3) now the syringe lies at its starting spot on the shelf: barrel centre within 60 mm horizontally of its start position, barrel axis within about 20.5 deg of horizontal (|vertical component| < 0.35), barrel centre within 80 mm of the shelf top height, moving slower than 0.05 m/s. 'Seated' = nozzle tip within 6 mm horizontally of the mouth centre, from 12 mm below to 12 mm above its rim, plunger end up with the barrel within ~31.8 deg of vertical, counted for 10 substeps after it last held. Not true at the start."
}