The first exam for code agents in the physical world: frozen robot tasks from many benchmark suites, each answered with a program and verified in a separate sandbox. Runs on Harbor.
Python ai-agentsbenchmarkcoding-agentsembodied-aievaluationharborllm-agentsrobot-learningroboticssimulation
MyoSuite table_tennis standard-realtime: the instruction says the realtime client sends float64 rows (it said float32, the 2.2 client's) (#213)
Kangrui Wang087bbebaca9e
diff --git a/scripts/myosuite/generate.py b/scripts/myosuite/generate.pyindex 9cc35de53b..c2f69e1f62 100644--- a/scripts/myosuite/generate.py+++ b/scripts/myosuite/generate.py@@ -403,7 +403,7 @@ Each proprioception row (`meta["proprio"]["now"]`, `res.proprio`) has, in `spec(### Action type `{atype}` ({f["nu"]}){actuation(f)} Columns in `spec()["action_types"]["{atype}"]["layout"]` order; rows `dt` apart, `interpolate="linear"`-(default: a straight line from the commands in force) or `"hold"`; the client sends them as float32. The control rate+(default: a straight line from the commands in force) or `"hold"`; the realtime client sends them as float64. The control rateis {hz} Hz ({f["frame_skip"]} physics substeps)."""diff --git a/tasks/myosuite-table-tennis-i00-standard-realtime/instruction.md b/tasks/myosuite-table-tennis-i00-standard-realtime/instruction.mdindex 8f92b131c5..212218f7a3 100644--- a/tasks/myosuite-table-tennis-i00-standard-realtime/instruction.md+++ b/tasks/myosuite-table-tennis-i00-standard-realtime/instruction.md@@ -93,7 +93,7 @@ Each proprioception row (`meta["proprio"]["now"]`, `res.proprio`) has, in `spec(### Action type `actuators` (275)275 real numbers per control step, one per actuator in order: 273 muscles and 2 non-muscle actuators. A muscle's command a maps to its excitation u = 1 / (1 + exp(-5 (a - 0.5))) and is not clipped (a = -1: u ~ 0.0006, a = 0.5: 0.5, a = 1: 0.92, a = 2: 0.9994); activation follows excitation with a first-order delay (~10 ms up, ~40 ms down); muscles only pull; one muscle can cross several joints; its force also depends on its length and velocity. The non-muscle actuators: `pelvis_x` (index 273): normalized: a in [-1, 1] maps linearly onto [-1, 0.05] (position of joint pelvis_x); `pelvis_y` (index 274): normalized: a in [-1, 1] maps linearly onto [-1, 1] (position of joint pelvis_y). Columns in `spec()["action_types"]["actuators"]["layout"]` order; rows `dt` apart, `interpolate="linear"`-(default: a straight line from the commands in force) or `"hold"`; the client sends them as float32. The control rate+(default: a straight line from the commands in force) or `"hold"`; the realtime client sends them as float64. The control rateis 100 Hz (5 physics substeps).## External material