The agent that grows with you
Python aiai-agentai-agentsanthropicchatgptclaudeclaude-codecodexhermeshermes-agentllmnous-researchopenai
"""LIVE Windows E2E for #48820 (4th repro): Job-Object teardown vs the
gateway restart watcher, with real processes on a real windows-latest runner.
Three live proofs (no mocks of the code under test):
1. ``TestJobObjectMechanismLive`` — the mechanism everything rests on:
a child spawned with ``windows_detach_flags()`` (CREATE_BREAKAWAY_FROM_JOB)
from inside a kill-on-close Job Object SURVIVES the job teardown, while a
child spawned with ``windows_detach_flags_without_breakaway()`` is killed
by it. This is exactly the reporter's suspected kill path.
2. ``TestWatcherRespawnLive`` — drives the REAL
``hermes_cli.gateway._spawn_gateway_restart_watcher`` end to end with a
real stub gateway process, against a temp HERMES_HOME:
- the respawned process's stderr must land in ``logs/gateway-stdio.log``
(on unfixed main it went to DEVNULL: a job-teardown kill left ZERO trace);
- the respawn env must carry ``_HERMES_GATEWAY_BREAKAWAY=1`` (the stamp
that makes a later job-teardown death diagnosable in exit-diag).
3. ``TestResumeVerificationLive`` — the user-visible symptom: the updater's
``_resume_windows_gateways_after_update`` must NOT print
"✓ Restarting Windows gateway profile(s)" when the relaunched gateway is
dead. The relaunch chain runs for real; the "gateway" is a stub that exits
immediately (standing in for the job-teardown kill). On unfixed main the ✓
is printed anyway; after the fix the resume raises "not verified alive".
"""
from __future__ import annotations
import contextlib
import ctypes
import subprocess
import sys
import time
from ctypes import wintypes
from pathlib import Path
import pytest
pytestmark = pytest.mark.platforms("windows") # native Windows only
_REPO_ROOT = Path(__file__).resolve().parents[2]
JOB_OBJECT_LIMIT_KILL_ON_JOB_CLOSE = 0x00002000
JOB_OBJECT_LIMIT_BREAKAWAY_OK = 0x00000800
JobObjectExtendedLimitInformation = 9
CREATE_SUSPENDED = 0x00000004
SYNCHRONIZE = 0x00100000
PROCESS_QUERY_LIMITED_INFORMATION = 0x1000
WAIT_OBJECT_0 = 0x0
WAIT_TIMEOUT = 0x102
class IO_COUNTERS(ctypes.Structure):
_fields_ = [
("ReadOperationCount", ctypes.c_ulonglong),
("WriteOperationCount", ctypes.c_ulonglong),
("OtherOperationCount", ctypes.c_ulonglong),
("ReadTransferCount", ctypes.c_ulonglong),
("WriteTransferCount", ctypes.c_ulonglong),
("OtherTransferCount", ctypes.c_ulonglong),
]
class JOBOBJECT_BASIC_LIMIT_INFORMATION(ctypes.Structure):
_fields_ = [
("PerProcessUserTimeLimit", ctypes.c_longlong),
("PerJobUserTimeLimit", ctypes.c_longlong),
("LimitFlags", wintypes.DWORD),
("MinimumWorkingSetSize", ctypes.c_size_t),
("MaximumWorkingSetSize", ctypes.c_size_t),
("ActiveProcessLimit", wintypes.DWORD),
("Affinity", ctypes.c_size_t),
("PriorityClass", wintypes.DWORD),
("SchedulingClass", wintypes.DWORD),
]
class JOBOBJECT_EXTENDED_LIMIT_INFORMATION(ctypes.Structure):
_fields_ = [
("BasicLimitInformation", JOBOBJECT_BASIC_LIMIT_INFORMATION),
("IoInfo", IO_COUNTERS),
("ProcessMemoryLimit", ctypes.c_size_t),
("JobMemoryLimit", ctypes.c_size_t),
("PeakProcessMemoryUsed", ctypes.c_size_t),
("PeakJobMemoryUsed", ctypes.c_size_t),
]
def _kernel32():
# A private WinDLL with typed HANDLE signatures: windll's shared instance
# passes Python ints as 32-bit C ints, and argtypes set on it would leak
# into every other ctypes user in this process.
k = ctypes.WinDLL("kernel32", use_last_error=True)
k.CreateJobObjectW.argtypes = [ctypes.c_void_p, wintypes.LPCWSTR]
k.CreateJobObjectW.restype = wintypes.HANDLE
k.SetInformationJobObject.argtypes = [
wintypes.HANDLE,
ctypes.c_int,
ctypes.c_void_p,
wintypes.DWORD,
]
k.SetInformationJobObject.restype = wintypes.BOOL
k.AssignProcessToJobObject.argtypes = [wintypes.HANDLE, wintypes.HANDLE]
k.AssignProcessToJobObject.restype = wintypes.BOOL
k.IsProcessInJob.argtypes = [
wintypes.HANDLE,
wintypes.HANDLE,
ctypes.POINTER(wintypes.BOOL),
]
k.IsProcessInJob.restype = wintypes.BOOL
k.OpenProcess.argtypes = [wintypes.DWORD, wintypes.BOOL, wintypes.DWORD]
k.OpenProcess.restype = wintypes.HANDLE
k.WaitForSingleObject.argtypes = [wintypes.HANDLE, wintypes.DWORD]
k.WaitForSingleObject.restype = wintypes.DWORD
k.CloseHandle.argtypes = [wintypes.HANDLE]
k.CloseHandle.restype = wintypes.BOOL
return k
def _make_kill_on_close_job(k, allow_breakaway: bool) -> int:
job = k.CreateJobObjectW(None, None)
assert job, f"CreateJobObjectW failed (winerror={ctypes.get_last_error()})"
info = JOBOBJECT_EXTENDED_LIMIT_INFORMATION()
flags = JOB_OBJECT_LIMIT_KILL_ON_JOB_CLOSE
if allow_breakaway:
flags |= JOB_OBJECT_LIMIT_BREAKAWAY_OK
info.BasicLimitInformation.LimitFlags = flags
ok = k.SetInformationJobObject(
job,
JobObjectExtendedLimitInformation,
ctypes.byref(info),
ctypes.sizeof(info),
)
assert ok, f"SetInformationJobObject failed (winerror={ctypes.get_last_error()})"
return job
def _start_driver_in_job(k, job: int, argv: list[str]) -> subprocess.Popen:
"""Start ``argv`` inside ``job`` before it runs a single instruction.
The process is created suspended, assigned, then resumed — the same seam
the updater uses (``update_lock.bind_child_to_update_tree`` +
``resume_suspended_child``). Assigning a RUNNING process is racy: a venv's
``Scripts\\python.exe`` is a redirector that starts the real interpreter as
its own child, and a child created before ``AssignProcessToJobObject``
lands stays outside the job. That interpreter is the one that spawns the
grandchild, so the grandchild escaped the job and survived the teardown
(~6% of CI runs before this).
"""
from hermes_cli.update_lock import resume_suspended_child
driver = subprocess.Popen(argv, cwd=str(_REPO_ROOT), creationflags=CREATE_SUSPENDED)
if not k.AssignProcessToJobObject(job, int(driver._handle)):
error = ctypes.get_last_error()
driver.kill()
driver.wait(timeout=30)
pytest.fail(f"AssignProcessToJobObject failed (winerror={error})")
resume_suspended_child(driver)
return driver
def _read_pid(path: Path) -> int | None:
try:
text = path.read_text(encoding="utf-8-sig").strip()
except OSError:
return None
return int(text) if text.isdigit() else None
_SLEEPER = "import time; time.sleep(120)"
def _wait_for(predicate, timeout_s: float = 30.0, interval_s: float = 0.25):
deadline = time.monotonic() + timeout_s
while time.monotonic() < deadline:
if predicate():
return True
time.sleep(interval_s)
return False
class TestJobObjectMechanismLive:
"""Real Job Objects, real children — the #48820 kill mechanism."""
def _driver_source(self, flags_helper: str, pid_file: Path) -> str:
# The driver runs INSIDE the job and spawns a grandchild "gateway"
# with the flag bundle under test, then exits — mirroring the
# updater/watcher exiting while its job tears down. The pid lands via
# an atomic replace, so the file never exists empty.
return (
"import os, subprocess, sys, pathlib\n"
f"sys.path.insert(0, r'{_REPO_ROOT!s}')\n"
"from hermes_cli._subprocess_compat import (\n"
" windows_detach_flags, windows_detach_flags_without_breakaway)\n"
f"flags = {flags_helper}()\n"
f"p = subprocess.Popen([sys.executable, '-c', {_SLEEPER!r}],\n"
" creationflags=flags, stdin=subprocess.DEVNULL,\n"
" stdout=subprocess.DEVNULL, stderr=subprocess.DEVNULL)\n"
f"tmp = pathlib.Path(r'{pid_file}.tmp')\n"
"tmp.write_text(str(p.pid), encoding='utf-8')\n"
f"os.replace(tmp, r'{pid_file}')\n"
)
@contextlib.contextmanager
def _grandchild_after_teardown(self, tmp_path: Path, flags_helper: str):
"""Yield ``(kernel32, grandchild handle, was in the job)`` right after
the job's last handle closed.
The grandchild is watched through a handle opened while it was alive,
never by pid: a pid freed by the kill can be reused by another process
on a busy runner, and a handle also lets the kill be awaited instead of
guessed with a fixed sleep.
"""
k = _kernel32()
pid_file = tmp_path / f"{flags_helper}.pid"
job = _make_kill_on_close_job(k, allow_breakaway=True)
gw = None
gw_pid = None
try:
argv = [sys.executable, "-c", self._driver_source(flags_helper, pid_file)]
driver = _start_driver_in_job(k, job, argv)
assert _wait_for(lambda: _read_pid(pid_file) is not None), (
"driver never wrote the pid file"
)
gw_pid = _read_pid(pid_file)
gw = k.OpenProcess(
SYNCHRONIZE | PROCESS_QUERY_LIMITED_INFORMATION, False, gw_pid
)
assert gw, (
f"OpenProcess({gw_pid}) failed (winerror={ctypes.get_last_error()})"
)
assert driver.wait(timeout=30) is not None, "driver did not exit"
assert k.WaitForSingleObject(gw, 0) == WAIT_TIMEOUT, (
"grandchild died before job teardown"
)
in_job = wintypes.BOOL(False)
assert k.IsProcessInJob(gw, job, ctypes.byref(in_job)), (
f"IsProcessInJob failed (winerror={ctypes.get_last_error()})"
)
# THE teardown: closing the last job handle fires
# KILL_ON_JOB_CLOSE against every process still in the job.
assert k.CloseHandle(job), "CloseHandle(job) failed"
job = None
yield k, gw, bool(in_job.value)
finally:
if job:
k.CloseHandle(job)
if gw_pid:
subprocess.run(
["taskkill", "/PID", str(gw_pid), "/T", "/F"],
capture_output=True,
check=False,
)
if gw:
k.CloseHandle(gw)
def test_breakaway_child_survives_job_teardown(self, tmp_path):
with self._grandchild_after_teardown(
tmp_path, "windows_detach_flags"
) as (k, gw, in_job):
assert not in_job, "a CREATE_BREAKAWAY_FROM_JOB child must leave the job"
assert k.WaitForSingleObject(gw, 2000) == WAIT_TIMEOUT, (
"CREATE_BREAKAWAY_FROM_JOB child must survive the parent "
"job's kill-on-close teardown"
)
def test_non_breakaway_child_killed_by_job_teardown(self, tmp_path):
"""The #48820 kill path, reproduced live: no breakaway → the job's
teardown reaps the freshly spawned gateway."""
with self._grandchild_after_teardown(
tmp_path, "windows_detach_flags_without_breakaway"
) as (k, gw, in_job):
assert in_job, (
"precondition: a child spawned from inside the job without "
"CREATE_BREAKAWAY_FROM_JOB must be in the job"
)
assert k.WaitForSingleObject(gw, 30_000) == WAIT_OBJECT_0, (
"child without breakaway must be killed by kill-on-close "
"job teardown — this is the silent gateway death of #48820"
)
class TestWatcherRespawnLive:
"""Drive the real ``_spawn_gateway_restart_watcher`` with real processes."""
def _run_watcher_cycle(self, tmp_path: Path, monkeypatch) -> tuple[Path, Path]:
monkeypatch.setenv("HERMES_HOME", str(tmp_path / "home"))
(tmp_path / "home").mkdir(parents=True, exist_ok=True)
marker = tmp_path / "respawned.marker"
# The stub "gateway": records its breakaway stamp env, screams on
# stderr (so the stdio sidecar has something to capture), then exits.
stub = (
"import os, pathlib, sys\n"
f"pathlib.Path(r'{marker}').write_text(\n"
" os.environ.get('_HERMES_GATEWAY_BREAKAWAY', 'MISSING'),\n"
" encoding='utf-8')\n"
"print('stub-gateway-stderr-trace', file=sys.stderr)\n"
)
# A real old-pid that exits immediately — the watcher's poll loop
# sees it die and respawns.
old = subprocess.Popen([sys.executable, "-c", "pass"])
old.wait(timeout=30)
from hermes_cli import gateway
assert gateway._spawn_gateway_restart_watcher(
old.pid, [sys.executable, "-c", stub]
), "watcher spawn returned False"
assert _wait_for(marker.exists, timeout_s=60), (
"watcher never respawned the stub gateway"
)
stdio_log = tmp_path / "home" / "logs" / "gateway-stdio.log"
return marker, stdio_log
def test_respawn_stamps_breakaway_and_leaves_stdio_trace(
self, tmp_path, monkeypatch
):
marker, stdio_log = self._run_watcher_cycle(tmp_path, monkeypatch)
# (a) Breakaway stamp: on unfixed main the respawn env carried no
# stamp, so a job-teardown death was undiagnosable.
stamp = marker.read_text(encoding="utf-8-sig").strip()
assert stamp in {"1", "0"}, (
f"respawned gateway must carry the breakaway stamp, got {stamp!r}"
)
# (b) Stdio trace: on unfixed main stderr went to DEVNULL — a dying
# gateway left zero trace (#48820 4th repro).
assert _wait_for(
lambda: stdio_log.exists()
and "stub-gateway-stderr-trace"
in stdio_log.read_text(encoding="utf-8-sig", errors="replace"),
timeout_s=30,
), "respawned gateway stderr must land in logs/gateway-stdio.log"
class TestResumeVerificationLive:
"""The user-visible lie: '✓ Restarting' printed for a dead gateway."""
def test_dead_relaunch_is_not_reported_as_success(self, tmp_path, monkeypatch):
monkeypatch.setenv("HERMES_HOME", str(tmp_path / "home"))
(tmp_path / "home").mkdir(parents=True, exist_ok=True)
from hermes_cli import gateway
import hermes_cli.main as hm
from hermes_cli.update_cmd import _resume_windows_gateways_after_update
# Peripheral only: don't regenerate launcher scripts into the temp home.
monkeypatch.setattr(hm, "_refresh_windows_gateway_launchers", lambda: None)
# Real relaunch chain, real watcher, real spawn — but the respawned
# "gateway" exits immediately, standing in for the Job-Object
# teardown kill. It never registers in the process table as a
# gateway, exactly like the dead pid 48452 / 50456 of #48820.
def _relaunch(profile, old_pid):
dead = subprocess.Popen([sys.executable, "-c", "pass"])
dead.wait(timeout=30)
return gateway._spawn_gateway_restart_watcher(
dead.pid, [sys.executable, "-c", "pass"]
)
monkeypatch.setattr(
gateway, "launch_detached_profile_gateway_restart", _relaunch
)
token = {
"resume_needed": True,
"profiles": {"default": 999999},
"unmapped_pids": [],
"unmapped": [],
}
printed: list = []
real_print = print
monkeypatch.setattr(
"builtins.print", lambda *a, **k: printed.append(" ".join(map(str, a)))
)
try:
with pytest.raises(RuntimeError, match="not verified alive"):
_resume_windows_gateways_after_update(token)
finally:
monkeypatch.setattr("builtins.print", real_print)
text = "\n".join(printed)
assert "✓ Restarting" not in text, (
"the updater must not vouch for a gateway that is not alive "
f"(#48820). Printed:\n{text}"
)
assert "could not be verified" in text