Skip to content

The agent that grows with you

refactor(gateway): split start_gateway phases and log swallowed bootstrap errors

Teknium092fd21b2968
diff --git a/gateway/run_bootstrap.py b/gateway/run_bootstrap.py
index e6e9b03e896..956077175cb 100644
--- a/gateway/run_bootstrap.py
+++ b/gateway/run_bootstrap.py
@@ -1,16 +1,20 @@
"""Process startup phases; diagnostics remain in the gateway facade."""
from __future__ import annotations
+import logging
import threading
from pathlib import Path
from typing import Any, Optional
from gateway.config import GatewayConfig
+# Log-record parity with the origin module.
+logger = logging.getLogger("gateway.run")
+
async def _start_gateway_replace_existing_instance(existing_pid: int, replace: bool) -> bool:
"""Handle a live gateway PID under this HERMES_HOME: replace it (``--replace``) or refuse.
Returns False when startup must abort (refused, permission denied, target still alive)."""
- from gateway.run import (_clear_takeover_marker_quiet, _replace_target_belongs_to_other_profile, _wait_for_pid_exit, get_hermes_home, logger, suppress)
+ from gateway.run import (_clear_takeover_marker_quiet, _replace_target_belongs_to_other_profile, _wait_for_pid_exit, get_hermes_home, suppress)
from gateway.status import get_process_start_time, remove_pid_file, terminate_pid
if not replace:
hermes_home = str(get_hermes_home())
@@ -94,7 +98,7 @@ async def _start_gateway_replace_existing_instance(existing_pid: int, replace: b
if _released:
logger.info("Released %d stale scoped lock(s) from old gateway.", _released)
except Exception:
- pass
+ logger.debug("Stale scoped lock release for replaced gateway PID %d failed", existing_pid, exc_info=True)
return True
@@ -414,7 +418,7 @@ async def _start_gateway_shutdown_tail(
_planned_stop_watcher_stop: threading.Event, _planned_stop_watcher_thread: threading.Thread,
_signal_initiated_shutdown: list) -> bool:
"""Post-``wait_for_shutdown`` teardown; returns the process exit verdict (True = exit 0)."""
- from gateway.run import (_CRON_SHUTDOWN_DRAIN_TIMEOUT, _HOUSEKEEPING_SHUTDOWN_DRAIN_TIMEOUT, _await_thread_exit, _best_effort, _resolve_gateway_exit_verdict, _shutdown_mcp_servers_nonblocking, _stop_cron_provider, logger, suppress)
+ from gateway.run import (_CRON_SHUTDOWN_DRAIN_TIMEOUT, _HOUSEKEEPING_SHUTDOWN_DRAIN_TIMEOUT, _await_thread_exit, _best_effort, _resolve_gateway_exit_verdict, _shutdown_mcp_servers_nonblocking, _stop_cron_provider)
# Control socket first: once shutdown begins we are no longer a truthful "serving here" answer and a
# successor must be able to bind. Early-exit paths rely on the atexit cleanup_files hook instead.
if _control_server is not None:
@@ -496,16 +500,125 @@ def _launch_home_may_multiplex(config=None) -> bool:
raise SystemExit(GATEWAY_FATAL_CONFIG_EXIT_CODE)
+def _start_gateway_resolve_terminal_cwd() -> None:
+ """Messaging-only defaults belong to startup, not incidental imports by the TUI."""
+ import os
+ from gateway.cwd_placeholder import CWD_PLACEHOLDERS, resolve_placeholder_terminal_cwd
+ configured_cwd = os.environ.get("TERMINAL_CWD", "")
+ if not configured_cwd or configured_cwd in CWD_PLACEHOLDERS:
+ resolved_cwd = resolve_placeholder_terminal_cwd(
+ configured_cwd=configured_cwd,
+ terminal_backend=os.environ.get("TERMINAL_ENV", ""),
+ messaging_cwd=os.getenv("MESSAGING_CWD"),
+ docker_mount_cwd_to_workspace=os.getenv(
+ "TERMINAL_DOCKER_MOUNT_CWD_TO_WORKSPACE", "false").lower()
+ in {"true", "1", "yes"},
+ home_fallback=str(Path.home()))
+ if resolved_cwd is None:
+ os.environ.pop("TERMINAL_CWD", None)
+ else:
+ os.environ["TERMINAL_CWD"] = resolved_cwd
+
+
+def _start_gateway_reserve_profiles(profile_homes) -> bool:
+ """Reserve the launch home plus every served profile home; False when startup must abort."""
+ from gateway.run import get_hermes_home
+ from gateway.runtime_ownership import process_ownership, OwnershipConflict
+ try:
+ process_ownership.reserve([get_hermes_home(), *(home for _, home in profile_homes)])
+ except OwnershipConflict as exc:
+ logger.error("Cannot reserve gateway profiles: %s", exc)
+ # A named profile that the LIVE default multiplexer already serves is a configuration
+ # verdict (gateway.multiplex_profiles), not a transient fault: exit EX_CONFIG so systemd's
+ # RestartPreventExitStatus=78 parks the unit instead of restart-looping (#51228, #97120).
+ # Any other same-user contender keeps the ordinary "already running" exit 1.
+ from hermes_cli.gateway import named_profile_served_by_running_multiplexer
+ if named_profile_served_by_running_multiplexer():
+ from gateway.restart import GATEWAY_FATAL_CONFIG_EXIT_CODE
+ from gateway.run import _write_runtime_status_quiet
+ logger.error(
+ "The default gateway is running as a profile multiplexer and already serves this profile. "
+ "Manage it with `hermes gateway restart` from the default profile instead of starting a "
+ "second gateway for the profile.")
+ _write_runtime_status_quiet(gateway_state="startup_failed", exit_reason=str(exc))
+ raise SystemExit(GATEWAY_FATAL_CONFIG_EXIT_CODE)
+ return False
+ except OSError as exc:
+ logger.error("Cannot reserve gateway profiles: %s", exc)
+ return False
+ return True
+
+
+def _start_gateway_install_signal_handlers(loop, shutdown_signal_handler, restart_signal_handler) -> None:
+ """SIGINT/SIGTERM drain, SIGUSR1 restart; main thread only."""
+ import signal
+ from contextlib import suppress
+ if threading.current_thread() is threading.main_thread():
+ # add_signal_handler raises NotImplementedError on Windows; SIGUSR1 is POSIX-only.
+ handlers = [(sig, shutdown_signal_handler, (sig,)) for sig in (signal.SIGINT, signal.SIGTERM)]
+ if hasattr(signal, "SIGUSR1"):
+ handlers.append((signal.SIGUSR1, restart_signal_handler, ())) # windows-footgun: ok — hasattr-guarded
+ for sig, handler, args in handlers:
+ with suppress(NotImplementedError):
+ loop.add_signal_handler(sig, handler, *args) # windows-footgun: ok — suppress(NotImplementedError)
+ else:
+ logger.info("Skipping signal handlers (not running in main thread).")
+
+
+async def _start_gateway_run_runner(runner, _signal_initiated_shutdown: list) -> Optional[bool]:
+ """MCP discovery, then ``runner.start()``. Returns the exit verdict when the process must end
+ before running mode (start failed, clean exit, aborted startup); None to continue into cron."""
+ from gateway.run import (_discover_gateway_mcp_tools, _resolve_gateway_exit_verdict,
+ _shutdown_gateway_health_export, _shutdown_mcp_servers_nonblocking)
+ # discover_mcp_tools() blocks up to 120s; on the loop thread it would freeze platform heartbeats.
+ try:
+ # MCP tool discovery — run in an executor so the asyncio event loop stays responsive even when a
+ # configured MCP server is slow or unreachable. discover_mcp_tools() uses a blocking 120s wait
+ # internally; calling it from the loop thread would freeze platform heartbeats (Discord shard,
+ # Telegram polling) until it returned. See #16856.
+ await _discover_gateway_mcp_tools(runner.config)
+ except Exception:
+ logger.debug("MCP tool discovery failed (non-fatal)", exc_info=True)
+
+ try:
+ success = await runner.start()
+ except BaseException:
+ _shutdown_gateway_health_export(runner)
+ raise
+ if not success:
+ _shutdown_gateway_health_export(runner)
+ return False
+
+ if runner.should_exit_cleanly:
+ _shutdown_gateway_health_export(runner)
+ if runner.exit_reason:
+ logger.error("Gateway exiting cleanly: %s", runner.exit_reason)
+ # Explicit exit codes (GATEWAY_FATAL_CONFIG_EXIT_CODE) must propagate so s6 finish maps 78 → 125.
+ if runner.exit_code is not None:
+ raise SystemExit(runner.exit_code)
+ return True
+ if not runner._running:
+ # Startup aborted by restart/shutdown before running mode; preserve that path without starting cron.
+ try:
+ await runner.wait_for_shutdown()
+ try:
+ await _shutdown_mcp_servers_nonblocking(config=getattr(runner, "config", None))
+ except Exception:
+ logger.warning("MCP shutdown failed; connections may be left open", exc_info=True)
+ return _resolve_gateway_exit_verdict(runner, _signal_initiated_shutdown[0])
+ finally:
+ _shutdown_gateway_health_export(runner)
+ return None
+
+
async def start_gateway(config: Optional[GatewayConfig] = None, replace: bool = False,
verbosity: Optional[int] = 0, force: bool = False) -> bool:
"""Start the gateway and run until interrupted; False if it failed to start (non-zero exit so
systemd can auto-restart). ``replace`` kills any existing instance first (avoids restart-loop
deadlocks); ``force`` starts without consulting the host owner at all."""
- from gateway.cwd_placeholder import CWD_PLACEHOLDERS, resolve_placeholder_terminal_cwd
from gateway.run import (
GatewayRunner,
_best_effort,
- _discover_gateway_mcp_tools,
_enable_multiplex_log_routing,
_ensure_windows_gateway_venv_imports,
_gateway_loop_exception_handler,
@@ -513,38 +626,16 @@ async def start_gateway(config: Optional[GatewayConfig] = None, replace: bool =
_log_standalone_profiles_at_boot,
_multiplex_profile_homes,
_refresh_host_gateway_record,
- _resolve_gateway_exit_verdict,
_run_planned_stop_watcher,
- _shutdown_gateway_health_export,
- _shutdown_mcp_servers_nonblocking,
_start_gateway_make_restart_signal_handler,
asyncio,
- get_hermes_home,
load_gateway_config_for_runner,
- logger,
os,
- signal,
- suppress,
threading,
)
# Set here (not at import) so incidental gateway.run imports from CLI code don't poison it.
os.environ["HERMES_EXEC_ASK"] = "1"
-
- # Messaging-only defaults belong to startup, not incidental imports by the TUI.
- configured_cwd = os.environ.get("TERMINAL_CWD", "")
- if not configured_cwd or configured_cwd in CWD_PLACEHOLDERS:
- resolved_cwd = resolve_placeholder_terminal_cwd(
- configured_cwd=configured_cwd,
- terminal_backend=os.environ.get("TERMINAL_ENV", ""),
- messaging_cwd=os.getenv("MESSAGING_CWD"),
- docker_mount_cwd_to_workspace=os.getenv(
- "TERMINAL_DOCKER_MOUNT_CWD_TO_WORKSPACE", "false").lower()
- in {"true", "1", "yes"},
- home_fallback=str(Path.home()))
- if resolved_cwd is None:
- os.environ.pop("TERMINAL_CWD", None)
- else:
- os.environ["TERMINAL_CWD"] = resolved_cwd
+ _start_gateway_resolve_terminal_cwd()
from hermes_cli.resource_limits import apply_nofile_soft_limit
apply_nofile_soft_limit()
@@ -576,29 +667,8 @@ async def start_gateway(config: Optional[GatewayConfig] = None, replace: bool =
and not await _start_gateway_replace_existing_instance(existing_pid, replace)):
return False
- from gateway.runtime_ownership import process_ownership, OwnershipConflict
from gateway.status import remove_pid_file, release_gateway_runtime_lock
- try:
- process_ownership.reserve([get_hermes_home(), *(home for _, home in profile_homes)])
- except OwnershipConflict as exc:
- logger.error("Cannot reserve gateway profiles: %s", exc)
- # A named profile that the LIVE default multiplexer already serves is a configuration
- # verdict (gateway.multiplex_profiles), not a transient fault: exit EX_CONFIG so systemd's
- # RestartPreventExitStatus=78 parks the unit instead of restart-looping (#51228, #97120).
- # Any other same-user contender keeps the ordinary "already running" exit 1.
- from hermes_cli.gateway import named_profile_served_by_running_multiplexer
- if named_profile_served_by_running_multiplexer():
- from gateway.restart import GATEWAY_FATAL_CONFIG_EXIT_CODE
- from gateway.run import _write_runtime_status_quiet
- logger.error(
- "The default gateway is running as a profile multiplexer and already serves this profile. "
- "Manage it with `hermes gateway restart` from the default profile instead of starting a "
- "second gateway for the profile.")
- _write_runtime_status_quiet(gateway_state="startup_failed", exit_reason=str(exc))
- raise SystemExit(GATEWAY_FATAL_CONFIG_EXIT_CODE)
- return False
- except OSError as exc:
- logger.error("Cannot reserve gateway profiles: %s", exc)
+ if not _start_gateway_reserve_profiles(profile_homes):
return False
# Freeze discovery: later profile additions must restart and reserve before opening stores.
if profile_homes:
@@ -650,16 +720,7 @@ async def start_gateway(config: Optional[GatewayConfig] = None, replace: bool =
# discoverable). Anything else is forwarded to the default handler so real bugs still surface.
loop.set_exception_handler(_gateway_loop_exception_handler)
- if threading.current_thread() is threading.main_thread():
- # add_signal_handler raises NotImplementedError on Windows; SIGUSR1 is POSIX-only.
- handlers = [(sig, shutdown_signal_handler, (sig,)) for sig in (signal.SIGINT, signal.SIGTERM)]
- if hasattr(signal, "SIGUSR1"):
- handlers.append((signal.SIGUSR1, restart_signal_handler, ())) # windows-footgun: ok — hasattr-guarded
- for sig, handler, args in handlers:
- with suppress(NotImplementedError):
- loop.add_signal_handler(sig, handler, *args) # windows-footgun: ok — suppress(NotImplementedError)
- else:
- logger.info("Skipping signal handlers (not running in main thread).")
+ _start_gateway_install_signal_handlers(loop, shutdown_signal_handler, restart_signal_handler)
# Windows has no add_signal_handler, so `hermes gateway stop`'s SIGTERM would never drain; poll the
# planned-stop marker (written BEFORE the kill) instead. Runs everywhere so masked-SIGTERM drains.
@@ -702,44 +763,9 @@ async def start_gateway(config: Optional[GatewayConfig] = None, replace: bool =
_best_effort(_start_keepalive, "Nous auth keepalive did not start: %s")
_ensure_windows_gateway_venv_imports()
- # discover_mcp_tools() blocks up to 120s; on the loop thread it would freeze platform heartbeats.
- try:
- # MCP tool discovery — run in an executor so the asyncio event loop stays responsive even when a
- # configured MCP server is slow or unreachable. discover_mcp_tools() uses a blocking 120s wait
- # internally; calling it from the loop thread would freeze platform heartbeats (Discord shard,
- # Telegram polling) until it returned. See #16856.
- await _discover_gateway_mcp_tools(runner.config)
- except Exception as e:
- logger.debug("MCP tool discovery failed: %s", e)
-
- try:
- success = await runner.start()
- except BaseException:
- _shutdown_gateway_health_export(runner)
- raise
- if not success:
- _shutdown_gateway_health_export(runner)
- return False
-
- if runner.should_exit_cleanly:
- _shutdown_gateway_health_export(runner)
- if runner.exit_reason:
- logger.error("Gateway exiting cleanly: %s", runner.exit_reason)
- # Explicit exit codes (GATEWAY_FATAL_CONFIG_EXIT_CODE) must propagate so s6 finish maps 78 → 125.
- if runner.exit_code is not None:
- raise SystemExit(runner.exit_code)
- return True
- if not runner._running:
- # Startup aborted by restart/shutdown before running mode; preserve that path without starting cron.
- try:
- await runner.wait_for_shutdown()
- try:
- await _shutdown_mcp_servers_nonblocking(config=getattr(runner, "config", None))
- except Exception:
- logger.warning("MCP shutdown failed; connections may be left open", exc_info=True)
- return _resolve_gateway_exit_verdict(runner, _signal_initiated_shutdown[0])
- finally:
- _shutdown_gateway_health_export(runner)
+ _early_verdict = await _start_gateway_run_runner(runner, _signal_initiated_shutdown)
+ if _early_verdict is not None:
+ return _early_verdict
cron_stop, cron_provider, cron_thread, housekeeping_thread = (
_start_gateway_start_cron_and_housekeeping(runner))