Skip to content

The agent that grows with you

fix(webapp-access): only the Hermes app on this computer can change Web Access

emozilla1378d5cf6652
diff --git a/hermes_cli/web_routers/webapp_access.py b/hermes_cli/web_routers/webapp_access.py
index 2026bd33a45..b6c008b095f 100644
--- a/hermes_cli/web_routers/webapp_access.py
+++ b/hermes_cli/web_routers/webapp_access.py
@@ -2,7 +2,8 @@
Thin HTTP over :mod:`hermes_cli.webapp_access`. Every handler acts on the home of the gateway that
serves the requested profile; start and stop write its ``webapp:`` config and restart that gateway,
-which reads the config only when it starts.
+which reads the config only when it starts. Only the machine's owner reaches them
+(:func:`owner_on_this_machine`), never a browser signed in over the network.
"""
from __future__ import annotations
@@ -11,7 +12,7 @@ import asyncio
from contextlib import contextmanager
from typing import Any, Callable, Optional
-from fastapi import APIRouter, HTTPException
+from fastapi import APIRouter, Depends, HTTPException, Request
from pydantic import BaseModel
from hermes_cli import webapp_access
@@ -20,7 +21,19 @@ from hermes_cli.web_routers._common import _profile_scope, config_write_scope, d
_restart_gateway_after = late("_restart_gateway_after", "hermes_cli.web_server_gateway")
-router = APIRouter()
+
+def owner_on_this_machine(request: Request) -> None:
+ """Web Access decides what this machine exposes, so only its owner here may use it: the native
+ app (a same-user gateway ticket, gated or not) or, on a listener without sign-in, the loopback
+ session token that ``auth_middleware`` has already checked. Behind the sign-in gate any other
+ caller is a cookie or bearer login, which may come from another device."""
+ if getattr(request.state, "native_http_principal", None):
+ return
+ if getattr(request.app.state, "auth_required", False):
+ raise HTTPException(status_code=403, detail="Web Access can only be changed from the Hermes app on this computer.")
+
+
+router = APIRouter(dependencies=[Depends(owner_on_this_machine)])
class StartBody(BaseModel):
diff --git a/tests/hermes_cli/test_webapp_access.py b/tests/hermes_cli/test_webapp_access.py
index 6caacfdab7e..fed9db76b3a 100644
--- a/tests/hermes_cli/test_webapp_access.py
+++ b/tests/hermes_cli/test_webapp_access.py
@@ -141,3 +141,63 @@ def test_start_keeps_a_custom_port_and_builds_the_addresses_on_it(client, restar
assert response.status_code == 200, response.text
assert _config()["webapp"]["port"] == 9333
assert response.json()["port"] == 9333
+
+
+def lan_browser(monkeypatch):
+ """This listener on all interfaces behind password sign-in, and a browser on the LAN signed in
+ with a cookie session."""
+ import plugins.dashboard_auth.basic as basic_plugin
+ from hermes_cli import web_server
+ from hermes_cli.dashboard_auth import clear_providers, register_provider
+ from hermes_cli.dashboard_auth.routes import _reset_password_rate_limit
+
+ monkeypatch.delenv("HERMES_DASHBOARD_PUBLIC_URL", raising=False)
+ for key, value in (("bound_host", "0.0.0.0"), ("bound_port", 9120), ("auth_required", True),
+ ("trusted_public_hosts", frozenset())):
+ monkeypatch.setattr(web_server.app.state, key, value, raising=False)
+ clear_providers()
+ register_provider(basic_plugin.BasicAuthProvider(
+ username="admin", password_hash=basic_plugin.hash_password("hunter2"), secret=b"s" * 32))
+ _reset_password_rate_limit()
+ browser = TestClient(web_server.app, base_url="http://192.168.1.50:9120")
+ login = browser.post("/auth/password-login", json={"provider": "basic", "username": "admin", "password": "hunter2"})
+ assert login.status_code == 200, login.text
+ yield browser
+ clear_providers()
+
+
+def test_a_browser_signed_in_over_the_network_cannot_use_web_access(lan_browser, restarts, nous):
+ """Web Access decides what this machine exposes, so only its owner here may use it. A browser
+ signed in behind the sign-in gate may be on another device: every Web Access route answers it
+ 403 and changes nothing, while the same session still reaches an ordinary route."""
+ page = {"Origin": "http://192.168.1.50:9120", "Sec-Fetch-Site": "same-origin"}
+
+ assert lan_browser.get("/api/config").status_code == 200
+ assert lan_browser.get("/api/webapp-access/status").status_code == 403
+ assert lan_browser.post("/api/webapp-access/start", json={"mode": "lan"}, headers=page).status_code == 403
+ assert lan_browser.post("/api/webapp-access/stop?profile=default", headers=page).status_code == 403
+ assert nous == []
+ assert restarts == []
+ assert not _config()["webapp"]["enabled"]
+
+
+def test_web_access_answers_the_native_app_and_the_loopback_token_only():
+ """The owner on this machine is the native app (its same-user gateway ticket, gated or not) or,
+ on a listener without sign-in, the holder of the loopback session token, which the auth
+ middleware has already checked. Behind the sign-in gate anything else is a remote login."""
+ from types import SimpleNamespace
+
+ from fastapi import HTTPException
+
+ from hermes_cli.web_routers.webapp_access import owner_on_this_machine
+
+ def request(*, gated: bool, native: bool):
+ return SimpleNamespace(app=SimpleNamespace(state=SimpleNamespace(auth_required=gated)),
+ state=SimpleNamespace(native_http_principal={"profile_id": "x"} if native else None))
+
+ owner_on_this_machine(request(gated=True, native=True))
+ owner_on_this_machine(request(gated=False, native=False))
+ with pytest.raises(HTTPException) as refused:
+ owner_on_this_machine(request(gated=True, native=False))
+ assert refused.value.status_code == 403