The agent that grows with you
Python aiai-agentai-agentsanthropicchatgptclaudeclaude-codecodexhermeshermes-agentllmnous-researchopenai
fix(s6): read the supervised pid from s6-svstat -o, not the status line
Victor Kyriazakos38880bd2f1e9
diff --git a/hermes_cli/service_manager.py b/hermes_cli/service_manager.pyindex 3e8d50762aa..f925c30b006 100644--- a/hermes_cli/service_manager.py+++ b/hermes_cli/service_manager.py@@ -549,16 +549,27 @@ class S6ServiceManager:self._run_svc("-u", "start", name)_write_gateway_desired_state(name, "running")+ def _svstat_fields(self, name: str, *fields: str) -> list[str] | None:+ """``s6-svstat -o <fields>`` values for ``name``, or None on a nonzero rc or a count mismatch.++ Never parse the human status line: s6 2.15 prints ``up (pid N pgid N) Ss``, which the old+ ``(pid N)`` regex never matched, so the planned-stop marker was silently skipped.+ """+ result = _s6_run("s6-svstat", "-o", ",".join(fields), str(self.scandir / name))+ if result.returncode != 0:+ return None+ values = result.stdout.split()+ return values if len(values) == len(fields) else None+def _supervised_pid(self, name: str) -> int | None:- """PID of the supervised gateway per ``s6-svstat``, or None on any failure."""+ """PID of the supervised gateway per ``s6-svstat -o pid`` (``-1`` when down), or None on any+ failure."""try:- result = _s6_run("s6-svstat", str(self.scandir / name))- except (OSError, subprocess.SubprocessError):- return None- if result.returncode != 0:+ values = self._svstat_fields(name, "pid")+ pid = int(values[0]) if values else 0+ except (OSError, subprocess.SubprocessError, ValueError):return None- m = re.search(r"\(pid (\d+)\)", result.stdout)- return int(m.group(1)) if m else None+ return pid if pid > 0 else Nonedef stop(self, name: str) -> None:"""``s6-svc -d``, after writing a planned-stop marker for the supervised PID so the gateway's@@ -580,8 +591,8 @@ class S6ServiceManager:_write_gateway_desired_state(name, "running")def is_running(self, name: str) -> bool:- result = _s6_run("s6-svstat", str(self.scandir / name))- return result.returncode == 0 and "up " in result.stdout+ values = self._svstat_fields(name, "up")+ return values == ["true"]# -- runtime registration ---------------------------------------------diff --git a/tests/docker/test_s6_gateway_planned_stop.py b/tests/docker/test_s6_gateway_planned_stop.pynew file mode 100644index 00000000000..d7a7d8c5dca--- /dev/null+++ b/tests/docker/test_s6_gateway_planned_stop.py@@ -0,0 +1,87 @@+"""E2E: ``hermes gateway stop`` inside the s6 image is a PLANNED stop.++``S6ServiceManager.stop()`` must find the supervised PID through the real s6+binaries and write the planned-stop marker before ``s6-svc -d``. Otherwise the+gateway reads the SIGTERM as an unexpected kill: it exits 1, persists+``gateway_state=running`` (so the next boot auto-starts it, undoing the stop)+and skips the clean-shutdown marker. Unit fakes cannot prove this; only the+real ``s6-svstat`` shipped in the image can.++Every ``docker exec`` runs as ``hermes`` per the conftest module docstring.+"""+from __future__ import annotations++import json+import time++from tests.docker.conftest import docker_exec_sh, start_container, wait_for_docker_logs++SLOT = "/run/service/gateway-default"+++def _svstat_field(container: str, field: str) -> str:+ r = docker_exec_sh(container, f"/command/s6-svstat -o {field} {SLOT}")+ return r.stdout.strip() if r.returncode == 0 else ""+++def _state(container: str) -> dict:+ r = docker_exec_sh(container, "cat /opt/data/gateway_state.json 2>/dev/null")+ if r.returncode != 0 or not r.stdout.strip():+ return {}+ try:+ data = json.loads(r.stdout)+ except json.JSONDecodeError:+ return {}+ return data if isinstance(data, dict) else {}+++def _gateway_state(container: str) -> str:+ return str(_state(container).get("gateway_state", ""))+++def _agent_log(container: str) -> str:+ return docker_exec_sh(container, "cat /opt/data/logs/agent.log 2>/dev/null").stdout+++def _wait(predicate, what: str, deadline_s: float = 90.0, interval_s: float = 0.5) -> None:+ end = time.monotonic() + deadline_s+ while time.monotonic() < end:+ if predicate():+ return+ time.sleep(interval_s)+ raise AssertionError(f"timed out after {deadline_s}s waiting for {what}")+++def test_gateway_stop_under_s6_is_planned(built_image: str, container_name: str) -> None:+ start_container(built_image, container_name, cmd="gateway run")+ wait_for_docker_logs(container_name, "s6 supervision", deadline_s=60.0)++ # The supervised gateway (no platforms: it stays up for cron) must be up and+ # past startup, so its signal handlers and planned-stop watcher are installed.+ # Boot seeds gateway_state=running before the process exists, so readiness is+ # the gateway's OWN state write (it stamps its pid) plus its startup-done line.+ _wait(lambda: _svstat_field(container_name, "up") == "true", "gateway-default up")+ supervised_pid = _svstat_field(container_name, "pid")+ assert supervised_pid.isdigit() and int(supervised_pid) > 0, supervised_pid+ _wait(+ lambda: str(_state(container_name).get("pid")) == supervised_pid+ and _gateway_state(container_name) == "running",+ "supervised gateway's own gateway_state=running write",+ )+ _wait(lambda: "Press Ctrl+C to stop" in _agent_log(container_name), "gateway startup done")++ r = docker_exec_sh(container_name, "hermes gateway stop", timeout=90)+ assert r.returncode == 0, f"gateway stop failed: stdout={r.stdout!r} stderr={r.stderr!r}"++ _wait(lambda: _svstat_field(container_name, "up") == "false", "gateway-default down")+ logs = docker_exec_sh(+ container_name, "cat /opt/data/logs/agent.log /opt/data/logs/gateway.log 2>/dev/null"+ ).stdout++ assert _svstat_field(container_name, "exitcode") == "0", (+ f"supervised gateway exit: {_svstat_field(container_name, 'exitcode')!r}\n"+ f"svstat: {docker_exec_sh(container_name, f'/command/s6-svstat {SLOT}').stdout!r}\n{logs[-4000:]}"+ )+ _wait(lambda: _gateway_state(container_name) == "stopped", "gateway_state=stopped", deadline_s=15.0)+ assert "as a planned gateway stop" in logs, logs[-4000:]+ assert "unexpected signal" not in logs, logs[-4000:]diff --git a/tests/hermes_cli/test_service_manager.py b/tests/hermes_cli/test_service_manager.pyindex 51474a810aa..0fe6ed9ebed 100644--- a/tests/hermes_cli/test_service_manager.py+++ b/tests/hermes_cli/test_service_manager.py@@ -7,6 +7,8 @@ implementation in this same file once that phase ships."""from __future__ import annotations+import subprocess+import pytestfrom hermes_cli.service_manager import (@@ -274,8 +276,151 @@ def test_render_finish_script_does_not_restart_on_clean_exit(tmp_path) -> None:# the marker, the gateway's shutdown handler can't tell an operator# stop from a restart kill, and the gateway_state=stopped suppression# (run.py) would never engage for explicit stops.+#+# The fake below replays what s6 2.15.0.0 (s6-overlay 3.2.3.0, pinned in the+# Dockerfile) actually prints, captured from the real binary:+# s6-svstat <dir> -> up (pid 26 pgid 26) 1 seconds+# s6-svstat -o pid <dir> -> 26 (-1 when not up)+# s6-svstat -o up <dir> -> true|false+# after s6-svc -d -> down (signal SIGTERM) 1 seconds, normally up, ready 1 seconds# ---------------------------------------------------------------------------+_S6_PID = 4242+++def real_s6(monkeypatch: pytest.MonkeyPatch):+ """Emulate s6 2.15 ``s6-svstat`` (legacy line and ``-o`` fields) plus ``s6-svc``.++ ``state["up"]`` toggles the supervised process; ``state["svstat"]`` may be set+ to a ``(returncode, stdout)`` override or an exception to raise.+ """+ _sp = subprocess+ state: dict = {"up": True, "svstat": None, "calls": []}++ def _fake(cmd, **kw):+ seq = list(cmd)+ name = seq[0].rsplit("/", 1)[-1]+ state["calls"].append([name, *seq[1:]])+ if name != "s6-svstat":+ return _sp.CompletedProcess(cmd, 0, "", "")+ override = state["svstat"]+ if isinstance(override, BaseException):+ raise override+ if override is not None:+ rc, out = override+ return _sp.CompletedProcess(cmd, rc, out, "")+ up = state["up"]+ if "-o" in seq:+ fields = seq[seq.index("-o") + 1].split(",")+ table = {+ "up": "true" if up else "false",+ "pid": str(_S6_PID) if up else "-1",+ "pgid": str(_S6_PID) if up else "-1",+ "exitcode": "-1" if up else "0",+ }+ assert all(f in table for f in fields), f"unknown s6-svstat field in {fields}"+ return _sp.CompletedProcess(cmd, 0, " ".join(table[f] for f in fields) + "\n", "")+ line = (+ f"up (pid {_S6_PID} pgid {_S6_PID}) 5 seconds\n"+ if up+ else "down (signal SIGTERM) 1 seconds, normally up, ready 1 seconds\n"+ )+ return _sp.CompletedProcess(cmd, 0, line, "")++ monkeypatch.setattr("subprocess.run", _fake)+ return state+++def marker_calls(monkeypatch: pytest.MonkeyPatch):+ marked: list[int] = []+ monkeypatch.setattr(+ "gateway.status.write_planned_stop_marker", lambda pid: marked.append(pid) or True+ )+ return marked+++def _svc_down_issued(state) -> bool:+ return any(c[:2] == ["s6-svc", "-d"] for c in state["calls"])+++def test_s6_stop_writes_planned_stop_marker_for_supervised_pid(+ s6_scandir, real_s6, marker_calls+) -> None:+ (s6_scandir / "gateway-coder").mkdir()+ mgr = S6ServiceManager(scandir=s6_scandir)++ mgr.stop("gateway-coder")++ assert marker_calls == [_S6_PID]+ assert _svc_down_issued(real_s6)+ svc_idx = next(i for i, c in enumerate(real_s6["calls"]) if c[:2] == ["s6-svc", "-d"])+ assert any(c[0] == "s6-svstat" for c in real_s6["calls"][:svc_idx])+++def test_s6_stop_when_down_writes_no_marker_but_still_stops(+ s6_scandir, real_s6, marker_calls+) -> None:+ (s6_scandir / "gateway-coder").mkdir()+ real_s6["up"] = False++ S6ServiceManager(scandir=s6_scandir).stop("gateway-coder")++ assert marker_calls == []+ assert _svc_down_issued(real_s6)+++def test_s6_stop_marker_write_failure_still_stops(+ s6_scandir, real_s6, monkeypatch: pytest.MonkeyPatch+) -> None:+ (s6_scandir / "gateway-coder").mkdir()+ attempted: list[int] = []++ def _boom(pid):+ attempted.append(pid)+ raise OSError("disk gone")++ monkeypatch.setattr("gateway.status.write_planned_stop_marker", _boom)++ S6ServiceManager(scandir=s6_scandir).stop("gateway-coder")++ assert attempted == [_S6_PID]+ assert _svc_down_issued(real_s6)+++def test_s6_supervised_pid_reads_up_pid(s6_scandir, real_s6) -> None:+ mgr = S6ServiceManager(scandir=s6_scandir)+ assert mgr._supervised_pid("gateway-coder") == _S6_PID+ real_s6["up"] = False+ assert mgr._supervised_pid("gateway-coder") is None+++ "svstat",+ [+ (1, "s6-svstat: fatal: unable to read status\n"),+ (0, "garbage\n"),+ (0, ""),+ (0, "4242 17\n"),+ (0, "0\n"),+ FileNotFoundError("/command/s6-svstat"),+ subprocess.TimeoutExpired("s6-svstat", 5),+ ],+)+def test_s6_supervised_pid_none_on_unusable_svstat(s6_scandir, real_s6, svstat) -> None:+ real_s6["svstat"] = svstat+ assert S6ServiceManager(scandir=s6_scandir)._supervised_pid("gateway-coder") is None+++def test_s6_is_running_follows_svstat_up_field(s6_scandir, real_s6) -> None:+ mgr = S6ServiceManager(scandir=s6_scandir)+ assert mgr.is_running("gateway-coder") is True+ real_s6["up"] = False+ assert mgr.is_running("gateway-coder") is False+ real_s6["svstat"] = (1, "")+ assert mgr.is_running("gateway-coder") is False+def _log_run_setup_fragment(rendered: str) -> str:"""Keep mkdir/rm setup from ``_render_log_run``; stop before ``s6-log``."""