Skip to content

The agent that grows with you

fix(computer-use): windowless, non-interactive Windows autostart repair

finn7636f29d8976704
diff --git a/hermes_cli/tools_config_cua.py b/hermes_cli/tools_config_cua.py
index 1d3246fdf45..219bb71527f 100644
--- a/hermes_cli/tools_config_cua.py
+++ b/hermes_cli/tools_config_cua.py
@@ -303,7 +303,13 @@ def install_cua_driver(upgrade: bool = False, require_confirmed_update: bool = F
suffix = "" if version is None else f": {version or 'unknown version'}"
_print_success(f" {driver_cmd} already installed{suffix}.")
if is_windows and not _repair_cua_driver_autostart_windows(binary, verbose=False):
- return _fail(" cua-driver is compatible, but Windows autostart repair failed.")
+ # Degrade, do not fail (#115017): the driver is installed and compatible — only its
+ # logon task is missing (declined or unavailable UAC consent, no interactive desktop).
+ # Returning False here made the whole install report failure, so a working Computer Use
+ # toolset read as broken and the install was re-attempted on the next run. The reachable
+ # next step is the manual elevated command.
+ _print_warning(" cua-driver is compatible; its logon auto-start was not registered.")
+ _print_info(" From an elevated shell, run: cua-driver autostart enable")
_print_cua_platform_notes(is_windows, is_linux, fresh_install=False)
return True
if repair_existing:
@@ -512,7 +518,16 @@ def _repair_cua_driver_autostart_windows(driver_cmd: str, *, verbose: bool) -> b
"""Best-effort repair for Windows installer autostart quoting failures.
Older install.ps1 builds interpolated the binary path into a PowerShell command string, which
split at the first space. If the scheduled task is missing, retry via Start-Process's
- structured ``-FilePath`` / ``-ArgumentList`` parameters instead."""
+ structured ``-FilePath`` / ``-ArgumentList`` parameters instead.
+
+ The wrapper itself must stay invisible and unattended (#115017): this runs from the shared
+ install/refresh path, which a windowless parent drives (Desktop backend, detached gateway, a
+ logon task). A ``powershell.exe`` spawned without ``CREATE_NO_WINDOW`` allocates its OWN console
+ there — a blank PowerShell window parked on the user's desktop for as long as the elevated
+ ``-Verb RunAs -Wait`` child lives — and without ``-NonInteractive`` that shell can sit on an
+ interactive prompt instead of unwinding. ``CREATE_NO_WINDOW`` (stdlib ``windows_hide_flags``,
+ the same seam every other spawn in this module uses) keeps stdio as pipes so the failure text
+ is still reported; the OS-owned UAC consent UI is unaffected."""
if sys.platform != "win32" or _cua_driver_autostart_registered_windows():
return True
binary = shutil.which(driver_cmd)
@@ -525,8 +540,10 @@ def _repair_cua_driver_autostart_windows(driver_cmd: str, *, verbose: bool) -> b
_print_info(" Registering cua-driver auto-start..." if verbose
else " Repairing cua-driver auto-start registration...")
try:
- result = _run_text([ps, "-NoProfile", "-ExecutionPolicy", "Bypass", "-Command", ps_cmd],
- timeout=300, env=_cua_driver_env())
+ result = _run_text([ps, "-NoProfile", "-NonInteractive", "-ExecutionPolicy", "Bypass",
+ "-Command", ps_cmd],
+ timeout=300, env=_cua_driver_env(),
+ creationflags=_post_setup_no_window_flags())
except subprocess.TimeoutExpired:
return _fail(" cua-driver autostart registration timed out.")
except Exception as exc:
diff --git a/tests/hermes_cli/test_install_cua_driver.py b/tests/hermes_cli/test_install_cua_driver.py
index 3683f7e0be8..f53e8c14a5e 100644
--- a/tests/hermes_cli/test_install_cua_driver.py
+++ b/tests/hermes_cli/test_install_cua_driver.py
@@ -1628,6 +1628,77 @@ class TestWindowsAutostartRepair:
assert f"$exe = '{driver}'" in ps_command
assert f"& {driver}" not in ps_command
+ @pytest.mark.windows_only
+ def test_repair_spawns_no_console_window_and_failure_degrades(self):
+ """``windows_only``: issue #115017 — the auto-start repair must not park a blank PowerShell
+ window on the desktop, and a failed repair must not fail the install.
+
+ This repair is reached from the shared install/refresh path, which a windowless parent
+ drives (Desktop backend, detached gateway, a logon task). A ``powershell.exe`` spawned
+ there WITHOUT ``CREATE_NO_WINDOW`` allocates its own console: a blank PowerShell window that
+ stays on screen for as long as the elevated ``-Verb RunAs -Wait`` child lives (verified live
+ on Windows 11: the window appears, and with ``CREATE_NO_WINDOW`` it never does). Without
+ ``-NonInteractive`` that shell can also sit on an interactive prompt instead of unwinding.
+ """
+ from hermes_cli import tools_config_cua as tools_config
+
+ create_no_window = 0x08000000
+ calls = []
+ driver = (
+ r"C:\Users\Ha Trung\AppData\Local\Programs\Cua"
+ r"\cua-driver\bin\cua-driver.exe"
+ )
+
+ def fake_which(name: str):
+ if name == "cua-driver":
+ return driver
+ if name == "powershell":
+ return r"C:\Windows\System32\WindowsPowerShell\v1.0\powershell.exe"
+ return None
+
+ def fake_run(cmd, **kwargs):
+ calls.append((cmd, kwargs))
+ if cmd[0] == "schtasks.exe": # task absent -> the repair branch runs
+ return SimpleNamespace(returncode=1, stdout="", stderr="")
+ return SimpleNamespace(returncode=1, stdout="", stderr="denied") # repair itself fails
+
+ with patch.object(tools_config.shutil, "which", side_effect=fake_which), \
+ patch("subprocess.run", side_effect=fake_run), \
+ patch.object(tools_config, "_post_setup_no_window_flags",
+ side_effect=lambda **kw: create_no_window), \
+ patch.object(tools_config, "_print_warning") as warn, \
+ patch.object(tools_config, "_print_info"):
+ assert tools_config._repair_cua_driver_autostart_windows(
+ "cua-driver", verbose=False
+ ) is False
+
+ ps_cmd, ps_kwargs = next(
+ (cmd, kwargs) for cmd, kwargs in calls
+ if str(cmd[0]).lower().endswith("powershell.exe")
+ )
+ assert ps_kwargs.get("creationflags") == create_no_window, (
+ "windowless spawn is the fix: without CREATE_NO_WINDOW the child allocates its own "
+ "visible console window on the user's desktop"
+ )
+ assert "-NonInteractive" in ps_cmd, "no interactive prompt may be presented"
+ assert ps_cmd[-2:] == ["-Command", ps_cmd[-1]], "script stays the -Command argument"
+ assert ps_kwargs.get("timeout"), "the repair must stay bounded, never block the caller"
+
+ # Degrade, do not fail: the driver is installed and compatible, only its logon task is
+ # missing — install_cua_driver must not report the whole toolset as broken.
+ with patch.object(tools_config, "_resolved_cua_driver_cmd", return_value=driver), \
+ patch.object(tools_config, "_cua_driver_contract_status",
+ return_value={"ready": True, "version": "0.20.0", "reason": ""}), \
+ patch.object(tools_config, "_cua_driver_version", return_value="0.20.0"), \
+ patch.object(tools_config, "_repair_cua_driver_autostart_windows",
+ return_value=False), \
+ patch.object(tools_config, "_print_success"):
+ assert tools_config.install_cua_driver(
+ upgrade=False, show_installer_progress=False
+ ) is True
+
+ assert any("auto-start" in str(call) for call in warn.call_args_list)
+
class TestCuaVersionSummary:
"""`hermes computer-use status` prints one line, whatever the binary says.