Skip to content

The agent that grows with you

fix(gateway): `hermes gateway restart` without a service unit no longer bails on linger

Teknium7f487df266c9
diff --git a/hermes_cli/gateway.py b/hermes_cli/gateway.py
index abeaef358bb..12a3bec0daf 100644
--- a/hermes_cli/gateway.py
+++ b/hermes_cli/gateway.py
@@ -6148,7 +6148,10 @@ def _cmd_restart(args):
except (subprocess.CalledProcessError, *swallow):
pass
- if supports_systemd_services():
+ # Linger only explains a FAILED systemd unit restart. Without an installed unit the
+ # detached run below is the restart; bailing here left `hermes gateway restart` a
+ # silent exit-0 no-op on any Linux login session (Desktop read it as success).
+ if kind == "systemd" and supports_systemd_services():
linger_ok, _detail = get_systemd_linger_status()
if linger_ok is not True:
import getpass
diff --git a/tests/hermes_cli/test_gateway_restart_no_unit_linger.py b/tests/hermes_cli/test_gateway_restart_no_unit_linger.py
new file mode 100644
index 00000000000..8008be9d3e1
--- /dev/null
+++ b/tests/hermes_cli/test_gateway_restart_no_unit_linger.py
@@ -0,0 +1,52 @@
+"""``hermes gateway restart`` without an installed service unit must actually restart.
+
+Linger is a systemd-unit concern. With no unit installed the detached ``run_gateway`` IS the
+restart, yet the linger check ran unconditionally and bailed with exit 0 on any Linux login
+session whose linger is off — the Desktop/dashboard "Restart gateway" action then reported
+success while nothing restarted and the saved credentials never loaded.
+"""
+from types import SimpleNamespace
+
+import pytest
+
+
+def test_restart_without_service_unit_runs_gateway_even_without_linger(monkeypatch):
+ from hermes_cli import gateway as gw
+
+ monkeypatch.setattr(gw, "_refuse_from_inside_gateway", lambda *a, **k: None)
+ monkeypatch.setattr(gw, "_dispatch_via_service_manager_if_s6", lambda *a, **k: False)
+ monkeypatch.setattr(gw, "_installed_service_kind_for", lambda windows: None)
+ monkeypatch.setattr(gw, "supports_systemd_services", lambda: True)
+ monkeypatch.setattr(gw, "get_systemd_linger_status", lambda *a, **k: (False, "Linger=no"))
+ monkeypatch.setattr(gw, "stop_profile_gateway", lambda: True)
+ monkeypatch.setattr(gw, "_wait_for_gateway_exit", lambda **k: None)
+ started = []
+ monkeypatch.setattr(gw, "run_gateway", lambda **k: started.append(k))
+
+ gw._cmd_restart(SimpleNamespace(system=False, all=False))
+
+ assert started, "no unit installed: restart must fall through to run_gateway, linger or not"
+
+
+def test_restart_with_systemd_unit_still_reports_missing_linger(monkeypatch):
+ from hermes_cli import gateway as gw
+
+ monkeypatch.setattr(gw, "_refuse_from_inside_gateway", lambda *a, **k: None)
+ monkeypatch.setattr(gw, "_dispatch_via_service_manager_if_s6", lambda *a, **k: False)
+ monkeypatch.setattr(gw, "_installed_service_kind_for", lambda windows: "systemd")
+
+ def _failing_service_call(*a, **k):
+ import subprocess
+ raise subprocess.CalledProcessError(1, ["systemctl"])
+
+ monkeypatch.setattr(gw, "_service_call", _failing_service_call)
+ monkeypatch.setattr(gw, "supports_systemd_services", lambda: True)
+ monkeypatch.setattr(gw, "get_systemd_linger_status", lambda *a, **k: (False, "Linger=no"))
+ started = []
+ monkeypatch.setattr(gw, "run_gateway", lambda **k: started.append(k))
+
+ gw._cmd_restart(SimpleNamespace(system=False, all=False))
+
+ assert not started, "a broken unit must surface the linger hint, not double-start a detached gateway"