Skip to content

The agent that grows with you

refactor(gateway): move the supervised-restart handback into gateway_supervised_restart.py

teknium18731bb91f57e
diff --git a/hermes_cli/AGENTS.md b/hermes_cli/AGENTS.md
index 20eaeabbad5..ac36c5f3cd7 100644
--- a/hermes_cli/AGENTS.md
+++ b/hermes_cli/AGENTS.md
@@ -155,6 +155,11 @@ other service domain / UNIX user / HERMES_HOME outside `profiles/` — notices f
blockers for the hook) and the `gateway.auto_multiplex_migration` opt-out (#109954). Blockers reuse `GatewayRunner._adapter_credential_fingerprint` and `platform_binds_port`;
"has a `/p/<profile>/` ingress" is the adapter class attribute `serves_profile_prefix` — set it on a
new HTTP-inbound adapter when it answers the prefix, never extend a list here.
+`hermes gateway restart` for a gateway Hermes did not install (custom launchd agent / unit running
+`gateway run --external-supervisor`): `gateway_supervised_restart.py` — the gateway's SELF-declared
+supervisor (control-socket `identify`, then the argv marker) decides; hand back via SIGUSR1 and wait
+for a fresh supervised PID, never stop + foreground `run_gateway` (that stamps the CLI's PID and wedges
+every KeepAlive respawn, #110637).
## Nous free tier (`hermes_cli/anon_auth.py`)
diff --git a/hermes_cli/gateway.py b/hermes_cli/gateway.py
index c6080e8c1a7..39a6ef0ab8f 100644
--- a/hermes_cli/gateway.py
+++ b/hermes_cli/gateway.py
@@ -6262,36 +6262,6 @@ def _restart_all(system: bool) -> None:
_service_call(kind, "start", system)
-def _wait_for_supervised_gateway_replacement(
- old_pid: int, timeout: float | None = None, *, poll_interval: float = 0.5
-) -> int | None:
- """Poll the pidfile until the supervisor's replacement gateway registers a fresh PID.
-
- A graceful SIGUSR1 exit only proves the old process left — an unloaded, broken, or
- stopped-retrying supervisor leaves the gateway down. Custom-supervisor counterpart of
- ``_wait_for_launchd_service_pid``: the label is invisible to launchctl queries, so
- identity comes from ``get_running_pid``'s lock+PID liveness verification and freshness
- from ``!= old_pid``. Returns the fresh PID, or None once ``timeout`` passes.
- """
- from gateway.status import get_running_pid
-
- if timeout is None:
- timeout = SUPERVISED_REPLACEMENT_VERIFY_TIMEOUT
- deadline = time.monotonic() + max(timeout, 0.5)
- while True:
- pid = get_running_pid()
- if pid is not None and pid > 0 and pid != old_pid:
- return pid
- if time.monotonic() >= deadline:
- return None
- time.sleep(poll_interval)
-
-
-# A custom KeepAlive supervisor keeps its own respawn interval (launchd's is ~once per 10s,
-# per LAUNCHD_SUPERVISION_VERIFY_TIMEOUT); 15s matches _wait_for_launchd_service_pid's budget.
-SUPERVISED_REPLACEMENT_VERIFY_TIMEOUT = 15.0
-
-
def _cmd_restart(args):
_refuse_from_inside_gateway("restart", "restart loops")
system = getattr(args, "system", False)
@@ -6340,43 +6310,17 @@ def _cmd_restart(args):
)
sys.exit(1)
- # An externally-supervised gateway (custom launchd agent running `gateway run
- # --external-supervisor`) must restart by exiting back to its supervisor. A foreground
- # run here stamps this CLI's PID as the gateway; every KeepAlive respawn then refuses
- # with "Gateway already running" and the gateway stays down until the restart process
- # is killed (#110637). Same argv marker the update path trusts
- # (_prepare_profile_gateway_update_restart).
+ # A gateway that declares an external supervisor (custom launchd agent / unit running
+ # `gateway run --external-supervisor`) restarts by exiting back to it: the stop + foreground
+ # run below would stamp this CLI's PID as the gateway and wedge every respawn (#110637).
from gateway.status import get_running_pid
+ from hermes_cli.gateway_supervised_restart import (
+ gateway_declares_external_supervisor, restart_externally_supervised_gateway,
+ )
supervised_pid = get_running_pid()
- supervised_argv = _capture_gateway_argv(supervised_pid) if supervised_pid else None
- if supervised_argv and "--external-supervisor" in supervised_argv:
- wait_budget = _get_restart_exit_wait_budget()
- print(f"→ Restarting externally-supervised gateway (PID {supervised_pid}) — "
- f"draining in-flight runs (up to {wait_budget:.0f}s)...")
- if _graceful_restart_via_sigusr1(supervised_pid, wait_budget):
- # A clean exit doesn't prove supervision — the marker lives in argv, not in a
- # loaded job. launchd_restart verifies a replacement PID for the same reason:
- # a broken/unloaded supervisor must surface as a failed restart, never a
- # success printed over a dead gateway.
- replacement_pid = _wait_for_supervised_gateway_replacement(supervised_pid)
- if replacement_pid is not None:
- print()
- print(f"✓ Gateway relaunched by its supervisor (PID {replacement_pid})")
- return
- print("⚠ Supervisor did not relaunch the gateway after its graceful exit")
- else:
- print(f"⚠ Gateway drain timed out after {wait_budget:.0f}s")
- # The supervisor stays the sole restart owner: falling through to stop + foreground
- # run would SIGTERM a KeepAlive-armed process and stamp this CLI's PID, so every
- # supervisor respawn then refuses with "Gateway already running" (#110637) — the
- # exact wedge this handback exists to prevent. Fail loudly and leave ownership be.
- _print_lines(
- "",
- "✗ Not stopping or foreground-running a supervisor-owned gateway.",
- " Check the supervisor (it may be unloaded, wedged, or stopped retrying),",
- " then rerun once it is healthy: hermes gateway restart",
- )
- sys.exit(1)
+ if supervised_pid and gateway_declares_external_supervisor(supervised_pid):
+ restart_externally_supervised_gateway(supervised_pid)
+ return
if stop_profile_gateway():
print("✓ Stopped gateway for this profile")
diff --git a/hermes_cli/gateway_supervised_restart.py b/hermes_cli/gateway_supervised_restart.py
new file mode 100644
index 00000000000..c7823ab5c4c
--- /dev/null
+++ b/hermes_cli/gateway_supervised_restart.py
@@ -0,0 +1,100 @@
+"""``hermes gateway restart`` for a gateway whose supervisor Hermes did not install.
+
+A custom launchd agent / systemd unit / any KeepAlive-style manager running ``gateway run
+--external-supervisor`` owns the respawn. The manual fallback in ``_cmd_restart`` (SIGTERM, then a
+foreground ``run_gateway`` inside the restart CLI) stamps the CLI's own PID as the gateway, so every
+supervisor respawn refuses with "Gateway already running (PID <restart>)" and the gateway stays
+down until the restart process is killed (#110637). The gateway must instead exit back to its
+supervisor (SIGUSR1 drain), and success is a fresh supervised PID — never the bare exit.
+"""
+
+from __future__ import annotations
+
+import sys
+import time
+from pathlib import Path
+
+# A custom KeepAlive supervisor keeps its own respawn interval (launchd's is ~once per 10s,
+# per LAUNCHD_SUPERVISION_VERIFY_TIMEOUT); 15s matches _wait_for_launchd_service_pid's budget.
+SUPERVISED_REPLACEMENT_VERIFY_TIMEOUT = 15.0
+
+
+def gateway_declares_external_supervisor(pid: int, home: Path | None = None) -> bool:
+ """True when the running gateway ``pid`` was launched for an external supervisor.
+
+ The supervisor is SELF-declared by the gateway from its launch context: the control socket
+ ``identify`` answer (``supervisor: "external"``), else the ``--external-supervisor`` argv marker
+ read live (same marker ``_prepare_profile_gateway_update_restart`` trusts), else the argv the
+ gateway stamped into ``gateway_state.json`` when psutil cannot read the live command line.
+ """
+ if not pid or pid <= 1:
+ return False
+ from gateway.control_socket import identify_gateway
+ from gateway.status import _get_process_hermes_home, read_runtime_status
+ from hermes_cli.gateway import _capture_gateway_argv
+
+ home = home or _get_process_hermes_home()
+ identity = identify_gateway(home) or {}
+ if identity.get("pid") == pid and identity.get("supervisor"):
+ return identity.get("supervisor") == "external"
+ argv = _capture_gateway_argv(pid)
+ if argv is None:
+ record = read_runtime_status(home / "gateway_state.json") or {}
+ argv = record.get("argv") if record.get("pid") == pid else None
+ return bool(argv) and "--external-supervisor" in argv
+
+
+def _wait_for_supervised_gateway_replacement(
+ old_pid: int, timeout: float | None = None, *, poll_interval: float = 0.5
+) -> int | None:
+ """Poll the pidfile until the supervisor's replacement gateway registers a fresh PID.
+
+ A graceful SIGUSR1 exit only proves the old process left — an unloaded, broken, or
+ stopped-retrying supervisor leaves the gateway down. Custom-supervisor counterpart of
+ ``_wait_for_launchd_service_pid``: the label is invisible to launchctl queries, so identity
+ comes from ``get_running_pid``'s lock+PID liveness verification and freshness from ``!= old_pid``.
+ Returns the fresh PID, or None once ``timeout`` passes.
+ """
+ from gateway.status import get_running_pid
+
+ if timeout is None:
+ timeout = SUPERVISED_REPLACEMENT_VERIFY_TIMEOUT
+ deadline = time.monotonic() + max(timeout, 0.5)
+ while True:
+ pid = get_running_pid()
+ if pid is not None and pid > 0 and pid != old_pid:
+ return pid
+ if time.monotonic() >= deadline:
+ return None
+ time.sleep(poll_interval)
+
+
+def restart_externally_supervised_gateway(supervised_pid: int) -> None:
+ """Hand ``supervised_pid`` back to its supervisor (SIGUSR1 drain) and report the fresh PID.
+
+ Never falls through to SIGTERM + foreground run on either failure branch: that would
+ SIGTERM a KeepAlive-armed process and stamp this CLI's PID, recreating the competing-owner
+ wedge (#110637). A broken/unloaded supervisor surfaces as exit 1, not a success printed over
+ a dead gateway (the contract ``launchd_restart`` enforces via ``_wait_for_launchd_service_pid``).
+ """
+ from hermes_cli.gateway import _get_restart_exit_wait_budget, _graceful_restart_via_sigusr1, _print_lines
+
+ wait_budget = _get_restart_exit_wait_budget()
+ print(f"→ Restarting externally-supervised gateway (PID {supervised_pid}) — "
+ f"draining in-flight runs (up to {wait_budget:.0f}s)...")
+ if _graceful_restart_via_sigusr1(supervised_pid, wait_budget):
+ replacement_pid = _wait_for_supervised_gateway_replacement(supervised_pid)
+ if replacement_pid is not None:
+ print()
+ print(f"✓ Gateway relaunched by its supervisor (PID {replacement_pid})")
+ return
+ print("⚠ Supervisor did not relaunch the gateway after its graceful exit")
+ else:
+ print(f"⚠ Gateway drain timed out after {wait_budget:.0f}s")
+ _print_lines(
+ "",
+ "✗ Not stopping or foreground-running a supervisor-owned gateway.",
+ " Check the supervisor (it may be unloaded, wedged, or stopped retrying),",
+ " then rerun once it is healthy: hermes gateway restart",
+ )
+ sys.exit(1)
diff --git a/tests/hermes_cli/test_gateway_restart_external_supervisor.py b/tests/hermes_cli/test_gateway_restart_external_supervisor.py
index c797736735b..6cfafcec2d7 100644
--- a/tests/hermes_cli/test_gateway_restart_external_supervisor.py
+++ b/tests/hermes_cli/test_gateway_restart_external_supervisor.py
@@ -2,19 +2,10 @@
A custom launchd agent (a plist/label outside the canonical ``ai.hermes.gateway`` path, so
``_installed_service_kind_for`` returns None) fell through to the manual stop + foreground
-``run_gateway`` fallback. The foreground run stamps the restart CLI's own PID into
-gateway.pid, and every KeepAlive respawn of ``gateway run --external-supervisor`` then refuses
-with "Gateway already running (PID <restart>)" — the gateway stays down until the restart
-process is killed (#110637). The fix trusts the same ``--external-supervisor`` argv marker
-the update path uses (``_prepare_profile_gateway_update_restart``) and SIGUSR1s the gateway
-so it drains, exits, and lets the supervisor relaunch it.
-
-The handback keeps the supervisor the sole restart owner on both lifecycle branches: a
-graceful exit only reports success after a fresh, pidfile-verified replacement PID appears
-(a broken/unloaded supervisor must fail loudly, not print success over a dead gateway — the
-same contract ``launchd_restart`` enforces via ``_wait_for_launchd_service_pid``), and a
-drain timeout never falls back to SIGTERM + foreground run (that fallback recreates the
-competing-owner wedge this fix exists to remove).
+``run_gateway`` fallback. The foreground run stamps the restart CLI's own PID into gateway.pid,
+and every KeepAlive respawn of ``gateway run --external-supervisor`` then refuses with
+"Gateway already running (PID <restart>)" — the gateway stays down until the restart process is
+killed (#110637).
"""
from types import SimpleNamespace
@@ -22,6 +13,7 @@ import pytest
from gateway import status as gateway_status
from hermes_cli import gateway as gw
+from hermes_cli import gateway_supervised_restart as supervised
SUPERVISED_ARGV = [
"/usr/bin/python", "-m", "hermes_cli.main", "gateway", "run", "--external-supervisor",
@@ -31,16 +23,19 @@ SUPERVISED_ARGV = [
@pytest.fixture
def restart_calls(monkeypatch):
"""Drive ``_cmd_restart`` to the manual fallback (no service kind) and record the exits."""
- calls = {"sigusr1": None, "stopped": False, "started": False}
- replacement = {"pid": 5555}
+ calls = {"sigusr1": None, "stopped": False, "started": False, "sigusr1_returns": True, "replacement": 5555}
def _running_pid(*a, **k):
- # The supervised gateway holds the pidfile until the drain completes; after a
- # graceful exit only the supervisor's replacement can register a fresh PID.
+ # The supervised gateway holds the pidfile until the drain completes; after a graceful
+ # exit only the supervisor's replacement can register a fresh PID.
if calls["sigusr1"] is not None and calls["sigusr1_returns"]:
- return replacement["pid"]
+ return calls["replacement"]
return 4321
+ def _sigusr1(pid, budget, **k):
+ calls["sigusr1"] = (pid, budget)
+ return calls["sigusr1_returns"]
+
monkeypatch.setattr(gw, "_refuse_from_inside_gateway", lambda *a, **k: None)
monkeypatch.setattr(gw, "_guard_named_profile_under_multiplexer", lambda **k: None)
monkeypatch.setattr(gw, "_dispatch_via_service_manager_if_s6", lambda *a, **k: False)
@@ -48,18 +43,12 @@ def restart_calls(monkeypatch):
monkeypatch.setattr(gw, "_get_restart_exit_wait_budget", lambda: 7.0)
monkeypatch.setattr(gateway_status, "get_running_pid", _running_pid)
monkeypatch.setattr(gw, "_capture_gateway_argv", lambda pid: SUPERVISED_ARGV if pid == 4321 else None)
- monkeypatch.setattr(gw, "SUPERVISED_REPLACEMENT_VERIFY_TIMEOUT", 0.5)
-
- def _sigusr1(pid, budget, **k):
- calls["sigusr1"] = (pid, budget)
- return calls["sigusr1_returns"]
-
+ monkeypatch.setattr("gateway.control_socket.identify_gateway", lambda home, **k: None)
+ monkeypatch.setattr(supervised, "SUPERVISED_REPLACEMENT_VERIFY_TIMEOUT", 0.5)
monkeypatch.setattr(gw, "_graceful_restart_via_sigusr1", _sigusr1)
monkeypatch.setattr(gw, "stop_profile_gateway", lambda: calls.__setitem__("stopped", True) or True)
monkeypatch.setattr(gw, "_wait_for_gateway_exit", lambda **k: None)
monkeypatch.setattr(gw, "run_gateway", lambda **k: calls.__setitem__("started", True))
- calls["sigusr1_returns"] = True
- calls["_replacement"] = replacement
return calls
@@ -73,31 +62,22 @@ def test_external_supervisor_gateway_restarts_via_sigusr1_handback(restart_calls
assert not restart_calls["stopped"], "the CLI must not SIGTERM a supervisor-owned gateway"
assert not restart_calls["started"], "a foreground run would stamp the CLI PID and wedge respawns"
out = capsys.readouterr().out
- assert "relaunched by its supervisor" in out, (
- "success must ride on the verified replacement, not the bare exit"
+ assert "relaunched by its supervisor" in out and "5555" in out, (
+ "success must ride on the verified replacement PID, not the bare exit"
)
- assert "5555" in out, "the fresh supervisor PID is the success evidence"
-def test_graceful_exit_without_replacement_fails_loud(restart_calls, capsys):
- # An unloaded/broken supervisor never relaunches: the bare exit must not read as success.
- restart_calls["_replacement"]["pid"] = None
- with pytest.raises(SystemExit) as exc:
- _run_restart()
- assert exc.value.code == 1
- assert not restart_calls["stopped"] and not restart_calls["started"], \
- "the CLI must not take restart ownership from a broken supervisor either"
- assert "did not relaunch" in capsys.readouterr().out
-
-
-def test_drain_timeout_fails_loud_without_taking_ownership(restart_calls, capsys):
- restart_calls["sigusr1_returns"] = False
[email protected]("sigusr1_returns, replacement", [(True, None), (False, 5555)])
+def test_handback_failure_never_takes_ownership(restart_calls, sigusr1_returns, replacement):
+ # An unloaded supervisor (clean exit, no replacement) or a drain timeout must fail loudly;
+ # SIGTERM + foreground run would recreate the competing-owner wedge (#110637).
+ restart_calls["sigusr1_returns"] = sigusr1_returns
+ restart_calls["replacement"] = replacement
with pytest.raises(SystemExit) as exc:
_run_restart()
assert exc.value.code == 1
assert restart_calls["sigusr1"] == (4321, 7.0), "the graceful handback must be attempted first"
- assert not restart_calls["stopped"] and not restart_calls["started"], \
- "SIGTERM + foreground run would recreate the competing-owner wedge (#110637)"
+ assert not restart_calls["stopped"] and not restart_calls["started"]
def test_plain_manual_gateway_still_uses_stop_and_run(restart_calls, monkeypatch):
@@ -105,12 +85,3 @@ def test_plain_manual_gateway_still_uses_stop_and_run(restart_calls, monkeypatch
_run_restart()
assert restart_calls["sigusr1"] is None, "no supervisor marker: the detached fallback is the restart"
assert restart_calls["started"], "a plain manually-run gateway must still be restarted in-process"
-
-
[email protected]("pid,argv", [(None, None), (4321, None)])
-def test_uncapturable_gateway_still_uses_stop_and_run(restart_calls, monkeypatch, pid, argv):
- monkeypatch.setattr(gateway_status, "get_running_pid", lambda *a, **k: pid)
- monkeypatch.setattr(gw, "_capture_gateway_argv", lambda p: argv)
- _run_restart()
- assert restart_calls["sigusr1"] is None
- assert restart_calls["started"], "capture failure must degrade to the existing fallback, never a silent no-op"
diff --git a/website/docs/reference/cli-commands.md b/website/docs/reference/cli-commands.md
index 5e8b567d985..8e4181da810 100644
--- a/website/docs/reference/cli-commands.md
+++ b/website/docs/reference/cli-commands.md
@@ -313,8 +313,10 @@ Options:
| `--no-supervise` | On `run`: inside the s6-overlay Docker image, opt out of auto-supervision and use pre-s6 foreground semantics — gateway runs as the container's main process with no auto-restart. No-op outside the s6 image. Equivalent to setting `HERMES_GATEWAY_NO_SUPERVISE=1`. |
| `--external-supervisor` | On `run`: declare that a wrapper-provided process manager owns the foreground gateway. Use this when `sudo`, `env -i`, or another wrapper strips launchd/systemd's native environment marker. In-chat restarts and updates exit back to that manager instead of spawning a detached replacement. |
-`--external-supervisor` is a restart-policy contract: an in-chat restart or
-service-restart update exits with status `75`, so the wrapper's supervisor must
+`--external-supervisor` is a restart-policy contract: an in-chat restart,
+`hermes gateway restart`, or service-restart update exits with status `75`
+(the CLI then waits for the supervisor's fresh PID instead of running a
+foreground gateway of its own), so the wrapper's supervisor must
relaunch the gateway after that nonzero exit. For systemd, use
`Restart=on-failure` or `Restart=always` and do not include `75` in
`RestartPreventExitStatus`; for launchd, configure `KeepAlive` to relaunch after