The agent that grows with you
Python aiai-agentai-agentsanthropicchatgptclaudeclaude-codecodexhermeshermes-agentllmnous-researchopenai
Merge remote-tracking branch 'origin/main' into fix/106742-thread-resolution
teknium1ac353ee059fb
diff --cc gateway/run_adapters.pyindex 49317e2653c,ca506335d79..46307891be8--- a/gateway/run_adapters.py+++ b/gateway/run_adapters.py@@@ -1450,8 -1438,9 +1450,10 @@@ class GatewayAdapterLifecycleMixindef _primary_message_handler(self):"""Return the correctly scoped handler for a primary adapter."""- if self._multiplex_on():+ shared = getattr(self, 'session_authority', None) is not None- return self._make_default_profile_message_handler() if self._multiplex_on() or shared else self._handle_message++ if self._multiplex_on() or shared:+ return self._make_default_profile_message_handler()+ return self._standalone_scoped(self._handle_message)def _primary_busy_session_handler(self):"""Return the correctly scoped busy-session handler for a primary adapter."""diff --cc gateway/run_bootstrap.pyindex 136a9fe66cf,00000000000..ac82dfd7bd1mode 100644,000000..100644--- a/gateway/run_bootstrap.py+++ b/gateway/run_bootstrap.py@@@ -1,686 -1,0 +1,687 @@@+"""Process startup phases; diagnostics remain in the gateway facade."""+from __future__ import annotations++import threading+from typing import Any, Optional++from gateway.config import GatewayConfig++async def _start_gateway_replace_existing_instance(existing_pid: int, replace: bool) -> bool:+ """Handle a live gateway PID under this HERMES_HOME: replace it (``--replace``) or refuse.+ Returns False when startup must abort (refused, permission denied, target still alive)."""+ from gateway.run import (_clear_takeover_marker_quiet, _replace_target_belongs_to_other_profile, _wait_for_pid_exit, get_hermes_home, logger, suppress)+ from gateway.status import get_process_start_time, remove_pid_file, terminate_pid+ if not replace:+ hermes_home = str(get_hermes_home())+ logger.error(+ "Another gateway instance is already running (PID %d, HERMES_HOME=%s). "+ "Use 'hermes gateway restart' to replace it, or 'hermes gateway stop' first.",+ existing_pid, hermes_home)+ print(+ f"\n❌ Gateway already running (PID {existing_pid}).\n"+ f" Use 'hermes gateway restart' to replace it,\n"+ f" or 'hermes gateway stop' to kill it first.\n"+ f" Or use 'hermes gateway run --replace' to auto-replace.\n")+ return False++ # Never signal a process not provably ours (a poisoned PID record → cross-profile restart loop).+ if _replace_target_belongs_to_other_profile(existing_pid):+ from gateway.status import _get_process_hermes_home+ logger.error(+ "Refusing --replace: PID %d cannot be proven to belong "+ "to this profile's gateway (HERMES_HOME %s). Remove the "+ "stale PID record or stop the owning profile explicitly.",+ existing_pid, _get_process_hermes_home())+ return False+ existing_start_time = get_process_start_time(existing_pid)+ logger.info("Replacing existing gateway instance (PID %d) with --replace.", existing_pid)+ # Takeover marker: target exits 0 on our SIGTERM (exit 1 → systemd Restart=on-failure flap loop).+ try:+ from gateway.status import write_takeover_marker+ write_takeover_marker(existing_pid)+ except Exception as e:+ logger.debug("Could not write takeover marker: %s", e)+ # Snapshot children BEFORE signalling: reparented orphans are invisible yet hold scoped token locks.+ try:+ from gateway.status import _snapshot_gateway_children+ _old_gateway_children = _snapshot_gateway_children(existing_pid)+ except Exception:+ _old_gateway_children = []+ try:+ terminate_pid(existing_pid, force=False)+ except ProcessLookupError:+ pass # Already gone+ except (PermissionError, OSError):+ logger.error("Permission denied killing PID %d. Cannot replace.", existing_pid)+ _clear_takeover_marker_quiet()+ return False+ # Up to 10s for SIGTERM, then SIGKILL.+ if not await _wait_for_pid_exit(existing_pid, 20, 0.5):+ logger.warning("Old gateway (PID %d) did not exit after SIGTERM, sending SIGKILL.", existing_pid)+ old_gateway_exited = False+ try:+ terminate_pid(existing_pid, force=True, expected_start_time=existing_start_time)+ except ProcessLookupError:+ old_gateway_exited = True+ except (PermissionError, OSError):+ pass+ # Confirm SIGKILL took (D-state/zombie) before clearing PID/locks, or two gateways share a token.+ if not old_gateway_exited and not await _wait_for_pid_exit(existing_pid, 20, 0.25):+ logger.error(+ "Old gateway (PID %d) still appears alive after SIGKILL; "+ "aborting replacement to avoid a duplicate gateway.", existing_pid)+ _clear_takeover_marker_quiet()+ return False+ # Reap orphaned children (POSIX; mirrors Windows taskkill /T) so they stop holding scoped token locks.+ try:+ from gateway.status import reap_gateway_children+ reap_gateway_children(_old_gateway_children, parent_pid=existing_pid)+ except Exception:+ logger.debug("Child reap for replaced gateway PID %d failed", existing_pid, exc_info=True)+ remove_pid_file()+ # remove_pid_file() is a no-op when the PID doesn't match; force-unlink covers a crashed old process.+ with suppress(Exception):+ (get_hermes_home() / "gateway.pid").unlink(missing_ok=True)+ # The old process may not have consumed the marker (SIGKILL'd before its handler read it).+ _clear_takeover_marker_quiet()+ # Stopped (Ctrl+Z) processes don't release scoped locks on exit; stale lock files block the new gateway.+ try:+ from gateway.status import release_all_scoped_locks+ _released = release_all_scoped_locks(owner_pid=existing_pid, owner_start_time=existing_start_time)+ if _released:+ logger.info("Released %d stale scoped lock(s) from old gateway.", _released)+ except Exception:+ pass+ return True+++def _start_gateway_configure_logging(verbosity: Optional[int]) -> None:+ """Sync bundled skills, set up file logging + startup security audit, and the -v/-q stderr handler."""+ from gateway.run import (_best_effort, _gateway_stderr_formatter, _hermes_home, logging)+ def _sync_skills() -> None:+ from tools.skills_sync import sync_skills+ sync_skills(quiet=True)++ _best_effort(_sync_skills)++ # Centralized logging (agent.log INFO+, errors.log WARNING+, gateway.log gateway-only); idempotent.+ from hermes_logging import setup_logging, _safe_stderr+ setup_logging(hermes_home=_hermes_home, mode="gateway")++ def _security_audit() -> None:+ # Warn-on-load, never blocks: surfaces root / weak-SSH / unauthenticated-listener exposure.+ from hermes_cli.security_audit_startup import log_startup_security_warnings++ def _raw_cfg():+ from hermes_cli.config import read_raw_config+ return read_raw_config()++ log_startup_security_warnings(hermes_home=_hermes_home, config=_best_effort(_raw_cfg))++ _best_effort(_security_audit, "Startup security audit failed (non-fatal): %s")++ # Optional stderr handler from -v/-q: None (quiet) = none; 0 = WARNING; 1 = INFO; 2+ = DEBUG.+ if verbosity is not None:+ _stderr_level = {0: logging.WARNING, 1: logging.INFO}.get(verbosity, logging.DEBUG)+ _stderr_handler = logging.StreamHandler(_safe_stderr())+ _stderr_handler.setLevel(_stderr_level)+ _stderr_handler.setFormatter(_gateway_stderr_formatter())+ root = logging.getLogger()+ root.addHandler(_stderr_handler)+ if _stderr_level < root.level: # so DEBUG records can reach the handler+ root.setLevel(_stderr_level)+++def _start_gateway_make_shutdown_signal_handler(runner, _signal_initiated_shutdown: list):+ """Build the SIGINT/SIGTERM handler; ``_signal_initiated_shutdown[0]`` records an unplanned signal."""+ from gateway.run import (_best_effort, _hermes_home, asyncio, logger, signal)+ def shutdown_signal_handler(received_signal=None):+ # Planned --replace takeover (sibling marked this PID): exit 0 so systemd won't revive us.+ def _takeover() -> bool:+ from gateway.status import consume_takeover_marker_for_self+ return consume_takeover_marker_for_self()++ # Planned stop: CLI marks first, else its SIGTERM looks like an external kill. SIGINT = Ctrl+C.+ def _planned_stop() -> bool:+ from gateway.status import consume_planned_stop_marker_for_self+ return consume_planned_stop_marker_for_self()++ # Fast (<10ms) sync snapshot: stdlib + /proc, no subprocesses (`ps aux` here once blocked ~3s).+ def _snapshot():+ from gateway.shutdown_forensics import snapshot_shutdown_context+ return snapshot_shutdown_context(received_signal)++ planned_takeover = bool(_best_effort(_takeover, "Takeover marker check failed: %s"))+ planned_stop = received_signal == signal.SIGINT or (+ not planned_takeover and bool(_best_effort(_planned_stop, "Planned stop marker check failed: %s")))+ _shutdown_ctx = _best_effort(_snapshot, "snapshot_shutdown_context failed: %s")+ sig_name = _shutdown_ctx["signal"] if _shutdown_ctx else None++ if planned_takeover:+ logger.info("Received %s as a planned --replace takeover — exiting cleanly", sig_name or "SIGTERM")+ elif planned_stop:+ logger.info("Received %s as a planned gateway stop — exiting cleanly", sig_name or "SIGTERM/SIGINT")+ else:+ # Mirrored onto the runner so _stop_impl suppresses the gateway_state=stopped persist for+ # unexpected signals; operator stops take the `planned_stop` branch and leave it False (DO persist).+ _signal_initiated_shutdown[0] = runner._signal_initiated_shutdown = True+ logger.info("Received %s — initiating shutdown", sig_name or "SIGTERM/SIGINT")++ if _shutdown_ctx is not None:+ def _log_context() -> None:+ # The most useful line for "gateway keeps dying" tickets.+ from gateway.shutdown_forensics import format_context_for_log+ logger.warning("Shutdown context: %s", format_context_for_log(_shutdown_ctx))++ def _diagnostic() -> None:+ # Heavyweight (ps auxf, pstree, dmesg), detached so it finishes even if our cgroup is torn+ # down; bounded by an internal timeout, never blocks.+ from gateway.shutdown_forensics import spawn_async_diagnostic+ spawn_async_diagnostic(+ _hermes_home / "logs" / "gateway-shutdown-diag.log", _shutdown_ctx["signal"], timeout_seconds=5.0)++ _best_effort(_log_context, "format_context_for_log failed: %s")+ _best_effort(_diagnostic, "spawn_async_diagnostic failed: %s")+ asyncio.create_task(runner.stop())+ return shutdown_signal_handler+++def _start_gateway_claim_pid_file() -> bool:+ """Claim the runtime lock + PID file (O_EXCL winner is the authoritative gateway). False = lost."""+ from gateway.run import (logger, os)+ import atexit+ from gateway.status import (+ acquire_gateway_runtime_lock, get_running_pid, release_gateway_runtime_lock,+ remove_pid_file, write_pid_file)+ _current_pid = get_running_pid()+ if _current_pid is not None and _current_pid != os.getpid():+ logger.error("Another gateway instance (PID %d) started during our startup. "+ "Exiting to avoid double-running.", _current_pid)+ return False+ if not acquire_gateway_runtime_lock():+ logger.error("Gateway runtime lock is already held by another instance. Exiting.")+ return False+ try:+ write_pid_file()+ except FileExistsError:+ release_gateway_runtime_lock()+ logger.error("PID file race lost to another gateway instance. Exiting.")+ return False+ atexit.register(remove_pid_file)+ atexit.register(release_gateway_runtime_lock)+ return True+++async def _start_gateway_start_control_socket(runner):+ """Start the gateway control socket (identify/status/pause-for-update); None when unavailable."""+ from gateway.run import (asyncio, logger, os, threading)+ import atexit+ import concurrent.futures+ _control_server = None+ try:+ # Started immediately after the PID-file claim: winning that O_EXCL race is the moment this process+ # becomes the authoritative gateway for its HERMES_HOME, so from here on "does a socket answer?" is+ # a truthful liveness/identity query for updater and fleet consumers. Strictly non-fatal: a bind+ # failure only means consumers fall back to the process-scan/state-file layer, exactly as before+ # this feature. See #92091.+ from gateway.control_socket import GatewayControlServer, build_identify_payload- from gateway.run_profile_reconcile import migrate_profile_identity_verb++ from gateway.run_profile_reconcile import migrate_profile_identity_verb, purge_profile_identity_verb+ descriptor = runner.session_runtime_descriptor++ def _identify_runtime():+ payload = build_identify_payload()+ payload.update({key: descriptor[key] for key in (+ "instance_id", "runtime_protocol", "authority_epoch", "state", "api_origin",+ "served_profiles", "capabilities") if key in descriptor})+ if getattr(runner, '_draining', False):+ payload.update(state='draining', capabilities=[])+ payload["supervisor"] = {"manual": "none", "desktop": "none"}.get(+ payload.get("supervisor"), payload.get("supervisor", "none"))+ return payload+ # pause-for-update: the updater asks us to drain + exit (freeing venv handles) vs. a tree-kill+ # (same path as SIGUSR1). Handler runs on the socket executor thread, so marshal onto the loop.+ # pause-for-update (#92091 step 2): the updater asks this gateway to drain in-flight turns and exit+ # cleanly — releasing every venv file handle — instead of being tree-killed mid-turn. Same drain+ # path as SIGUSR1/service restarts (request_restart(via_service=True)); the updater (or the service+ # manager) relaunches after the code swap.+ _main_loop = asyncio.get_running_loop()++ def _pause_for_update_handler() -> dict:+ try:+ from hermes_cli.gateway import _get_restart_drain_timeout+ _drain = float(_get_restart_drain_timeout())+ except Exception:+ _drain = 30.0+ accepted_box: list[bool] = []+ _done = threading.Event()++ def _request() -> None:+ try:+ accepted_box.append(runner.request_restart(detached=False, via_service=True))+ finally:+ _done.set()++ _main_loop.call_soon_threadsafe(_request)+ _done.wait(timeout=5.0)+ accepted = bool(accepted_box and accepted_box[0])+ return {+ "pausing": accepted, "already_stopping": not accepted,+ "pid": os.getpid(), "drain_timeout": _drain}++ def _rescan_profiles_handler() -> dict:+ """``hermes profile create/delete`` asks the multiplexer to reconcile ``profiles/`` now+ (the watcher also rescans periodically). Runs on the socket executor: marshal onto the loop+ and wait briefly so the caller learns whether the profile is served."""+ if not getattr(runner.config, "multiplex_profiles", False):+ return {"multiplex": False, "served_profiles": runner.served_profile_names()}+ future = asyncio.run_coroutine_threadsafe(+ runner.reconcile_served_profiles(reason="control-socket"), _main_loop)+ try:+ # Bounded: a token-less create reconciles in milliseconds; a credential-add whose adapter+ # connect outlasts this keeps running and the caller sees ``pending`` (not an error).+ return {"multiplex": True, **future.result(timeout=5.0)}+ except concurrent.futures.TimeoutError:+ return {"multiplex": True, "pending": True, "served_profiles": runner.served_profile_names()}++ _control_server = GatewayControlServer(+ verb_handlers={"pause-for-update": _pause_for_update_handler, "identify": _identify_runtime,+ "rescan-profiles": _rescan_profiles_handler,- "migrate-profile-identity": migrate_profile_identity_verb(runner)})++ "migrate-profile-identity": migrate_profile_identity_verb(runner),++ "purge-profile-identity": purge_profile_identity_verb(runner)})+ _control_server.ticket_store = runner.session_ticket_store+ if not await _control_server.start():+ _control_server = None+ else:+ atexit.register(_control_server.cleanup_files)+ # Hosted-room transports install onto this listener; bind it here so every launcher+ # that starts the control socket (not only start_gateway) exposes it.+ runner.session_control_server = _control_server+ except Exception as _cs_exc:+ logger.debug("Control socket startup failed (non-fatal): %s", _cs_exc)+ _control_server = None+ return _control_server+++def _start_gateway_start_cron_and_housekeeping(runner):+ """Start the cron scheduler thread + gateway housekeeping thread; returns+ ``(cron_stop, cron_provider, cron_thread, housekeeping_thread)``."""+ from gateway.run import (Dict, Platform, _cron_tick_profile_homes, _start_gateway_housekeeping, asyncio, logger, threading)+ # The event loop is passed so cron delivery can use live adapters (E2EE support).+ from cron.scheduler_provider import (+ InProcessCronScheduler, resolve_cron_scheduler, scheduler_for_profile_mode)+ cron_stop = threading.Event()+ multiplex_cron = bool(getattr(runner.config, "multiplex_profiles", False))+ cron_provider = scheduler_for_profile_mode(+ resolve_cron_scheduler(), multiplex_profiles=multiplex_cron)+ cron_start_kwargs: Dict[str, Any] = {"adapters": runner.adapters, "loop": asyncio.get_running_loop()}++ # Multiplex: tell the ticker which profile homes to tick, else secondary profiles' jobs never run.+ if isinstance(cron_provider, InProcessCronScheduler) and multiplex_cron:+ try:+ profile_homes = _cron_tick_profile_homes(runner.config)+ if profile_homes:+ # Live enumerator: re-read per cycle so a hot-served profile's jobs fire without a restart.+ cron_start_kwargs["profile_homes"] = lambda: _cron_tick_profile_homes(runner.config)+ # Per-profile adapters so each profile's cron output goes via its own bot, not the default's.+ cron_start_kwargs["profile_adapters"] = getattr(runner, "_profile_adapters", None)+ # runner.adapters belongs to the LAUNCH profile (default, or the --profile name); naming+ # it keeps the ticker from routing a secondary's cron through that bot and lets a named+ # multiplexer's own jobs reuse its live adapters.+ cron_start_kwargs["default_profile"] = runner._primary_profile_name+ logger.info(+ "Cron scheduler will tick %d profile(s) under multiplex: %s", len(profile_homes),+ [p[0] if isinstance(p, tuple) else p for p in profile_homes])+ except Exception as exc:+ logger.warning("Could not resolve profile homes for multiplex cron: %s", exc)++ # Only the in-process ticker polls local due jobs, so only it gets the external-drain dispatch gate.+ if isinstance(cron_provider, InProcessCronScheduler):+ cron_start_kwargs["can_dispatch"] = lambda: not (+ runner._draining or runner._external_drain_active)+ # Supervised: a ticker that dies without a stop request is respawned by housekeeping (#111010).+ from cron.scheduler_thread import SupervisedTickerThread+ cron_thread = SupervisedTickerThread(+ cron_provider.start, args=(cron_stop,), kwargs=cron_start_kwargs, stop_event=cron_stop)+ from gateway.runtime_ownership import process_ownership+ process_ownership.start_writer(cron_thread)++ # External providers fire over loopback HTTP to THIS process's api_server; if it never came up (usually+ # API_SERVER_KEY missing) every fire fails while manual runs work — misread as a job bug. Say it ONCE.+ if not isinstance(cron_provider, InProcessCronScheduler):+ try:+ _has_api_server = Platform.API_SERVER in (runner.adapters or {})+ except Exception:+ _has_api_server = True # never let the tell break startup+ if not _has_api_server:+ logger.warning(+ "Cron provider '%s' is active but the api_server adapter is "+ "NOT running in this gateway — scheduled fires arrive over "+ "loopback HTTP and will all fail (jobs only run when "+ "triggered manually). Most common cause: API_SERVER_KEY is "+ "missing from this gateway process's environment. Restart "+ "the gateway through its supervisor (`hermes gateway "+ "restart`) so the profile env loads.",+ getattr(cron_provider, "name", "external"))++ # Gateway-only housekeeping runs independently of the cron provider; shares cron_stop for shutdown.+ housekeeping_thread = threading.Thread(+ target=_start_gateway_housekeeping, args=(cron_stop,),+ kwargs={"adapters": runner.adapters, "loop": asyncio.get_running_loop(),+ "cron_provider": cron_provider, "runner": runner, "cron_thread": cron_thread},+ daemon=True, name="gateway-housekeeping")+ process_ownership.start_writer(housekeeping_thread)+ return cron_stop, cron_provider, cron_thread, housekeeping_thread+++async def _start_gateway_shutdown_tail(+ runner, _control_server, cron_stop: threading.Event, cron_provider,+ cron_thread: Any, housekeeping_thread: threading.Thread,+ _planned_stop_watcher_stop: threading.Event, _planned_stop_watcher_thread: threading.Thread,+ _signal_initiated_shutdown: list) -> bool:+ """Post-``wait_for_shutdown`` teardown; returns the process exit verdict (True = exit 0)."""+ from gateway.run import (_CRON_SHUTDOWN_DRAIN_TIMEOUT, _HOUSEKEEPING_SHUTDOWN_DRAIN_TIMEOUT, _await_thread_exit, _best_effort, _resolve_gateway_exit_verdict, _shutdown_mcp_servers_nonblocking, _stop_cron_provider, logger, suppress)+ # Control socket first: once shutdown begins we are no longer a truthful "serving here" answer and a+ # successor must be able to bind. Early-exit paths rely on the atexit cleanup_files hook instead.+ if _control_server is not None:+ try:+ await _control_server.stop()+ except Exception:+ logger.debug("Control socket stop failed (non-fatal)", exc_info=True)++ def _stop_keepalive() -> None:+ from hermes_cli.nous_auth_keepalive import stop_nous_auth_keepalive+ stop_nous_auth_keepalive()++ _best_effort(_stop_keepalive)++ # Never join(): an in-flight cron delivery is a coroutine on THIS loop; a sync join would drop it.+ # Stop cron scheduler + housekeeping cleanly. These MUST be awaited cooperatively, not join()ed. A cron+ # delivery in flight when the gateway restarts is a coroutine scheduled onto THIS event loop+ # (safe_schedule_threadsafe); the ticker thread is blocked on its future.result(). A synchronous+ # cron_thread.join() would block the loop, so that delivery could never run — it timed out and the+ # message was silently dropped (#58818). Awaiting keeps the loop alive so the in-flight delivery+ # finishes before we tear down.+ cron_stop.set()+ _stop_cron_provider(cron_provider)+ if not await _await_thread_exit(cron_thread, timeout=_CRON_SHUTDOWN_DRAIN_TIMEOUT):+ logger.warning("Cron ticker did not exit within %.0fs of shutdown — an in-flight "+ "delivery may have been dropped.", _CRON_SHUTDOWN_DRAIN_TIMEOUT)+ await _await_thread_exit(housekeeping_thread, timeout=_HOUSEKEEPING_SHUTDOWN_DRAIN_TIMEOUT)++ # Stop the planned-stop watcher (daemon=True so this is belt-and-suspenders).+ _planned_stop_watcher_stop.set()+ _planned_stop_watcher_thread.join(timeout=2)++ with suppress(Exception):+ await _shutdown_mcp_servers_nonblocking()++ # The failure verdict comes AFTER the cooperative teardown: returning early here leaked the+ # cron ticker + housekeeping threads (and open MCP connections) for embedded callers (#12175).+ return _resolve_gateway_exit_verdict(runner, _signal_initiated_shutdown[0])++++def _launch_home_may_multiplex() -> bool:+ """A named profile serving ``default`` as a secondary splits default's local sessions between+ the two stores (routing rows follow the launch home, receipts follow the authority), so the+ multiplexer is the default profile's job. Exits EX_CONFIG: a config verdict, never a retry."""+ from hermes_constants import profile_name_for_home+ from gateway.run import get_hermes_home, logger+ name = profile_name_for_home(get_hermes_home())+ if name in (None, "default"):+ return True+ from gateway.restart import GATEWAY_FATAL_CONFIG_EXIT_CODE+ from gateway.run import _write_runtime_status_quiet+ logger.error(+ "gateway.multiplex_profiles is set on profile %r, but only the default profile can run the "+ "multiplexer. Unset the flag in this profile's config.yaml, or start the gateway from the "+ "default profile (`hermes gateway run`), which serves this profile too.", name)+ _write_runtime_status_quiet(gateway_state="startup_failed", exit_reason="multiplex_requires_default_profile")+ raise SystemExit(GATEWAY_FATAL_CONFIG_EXIT_CODE)+++async def start_gateway(config: Optional[GatewayConfig] = None, replace: bool = False, verbosity: Optional[int] = 0) -> bool:+ """Start the gateway and run until interrupted; False if it failed to start (non-zero exit so+ systemd can auto-restart). ``replace`` kills any existing instance first (avoids restart-loop deadlocks)."""+ from gateway.run import (+ GatewayRunner,+ _best_effort,+ _discover_gateway_mcp_tools,+ _enable_multiplex_log_routing,+ _ensure_windows_gateway_venv_imports,+ _gateway_loop_exception_handler,+ _multiplex_profile_homes,+ _resolve_gateway_exit_verdict,+ _run_planned_stop_watcher,+ _shutdown_gateway_health_export,+ _shutdown_mcp_servers_nonblocking,+ asyncio,+ get_hermes_home,+ load_gateway_config_for_runner,+ logger,+ os,+ signal,+ suppress,+ threading,+ )+ # Set here (not at import) so incidental gateway.run imports from CLI code don't poison it.+ os.environ["HERMES_EXEC_ASK"] = "1"++ from hermes_cli.resource_limits import apply_nofile_soft_limit+ apply_nofile_soft_limit()++ # Snapshot the revision while sys.modules matches disk so a later `git pull` is detected safely.+ from gateway.code_skew import record_boot_fingerprint+ record_boot_fingerprint()++ # Config verdicts come before the duplicate-instance guard: `--replace` must not stop a healthy+ # gateway for a launch that cannot start.+ resolved_config = config if config is not None else load_gateway_config_for_runner()+ profile_homes = (_multiplex_profile_homes(resolved_config)+ if getattr(resolved_config, 'multiplex_profiles', False) else [])+ if profile_homes and not _launch_home_may_multiplex():+ return False++ # Duplicate-instance guard scoped to HERMES_HOME; distinct-home multi-profile setups coexist.+ from gateway.status import get_running_pid+ existing_pid = get_running_pid()+ if (existing_pid is not None and existing_pid != os.getpid()+ and not await _start_gateway_replace_existing_instance(existing_pid, replace)):+ return False++ from gateway.runtime_ownership import process_ownership, OwnershipConflict+ from gateway.status import remove_pid_file, release_gateway_runtime_lock+ try:+ process_ownership.reserve([get_hermes_home(), *(home for _, home in profile_homes)])+ except OwnershipConflict as exc:+ logger.error("Cannot reserve gateway profiles: %s", exc)+ # A named profile that the LIVE default multiplexer already serves is a configuration+ # verdict (gateway.multiplex_profiles), not a transient fault: exit EX_CONFIG so systemd's+ # RestartPreventExitStatus=78 parks the unit instead of restart-looping (#51228, #97120).+ # Any other same-user contender keeps the ordinary "already running" exit 1.+ from hermes_cli.gateway import named_profile_served_by_running_multiplexer+ if named_profile_served_by_running_multiplexer():+ from gateway.restart import GATEWAY_FATAL_CONFIG_EXIT_CODE+ from gateway.run import _write_runtime_status_quiet+ logger.error(+ "The default gateway is running as a profile multiplexer and already serves this profile. "+ "Manage it with `hermes gateway restart` from the default profile instead of starting a "+ "second gateway for the profile.")+ _write_runtime_status_quiet(gateway_state="startup_failed", exit_reason=str(exc))+ raise SystemExit(GATEWAY_FATAL_CONFIG_EXIT_CODE)+ return False+ except OSError as exc:+ logger.error("Cannot reserve gateway profiles: %s", exc)+ return False+ # Freeze discovery: later profile additions must restart and reserve before opening stores.+ if profile_homes:+ resolved_config._runtime_profile_homes = tuple(profile_homes)+ if not _start_gateway_claim_pid_file():+ release_gateway_runtime_lock()+ return False++ _control_server = None+ runner = None+ _planned_stop_watcher_stop = None+ try:+ _start_gateway_configure_logging(verbosity)++ runner = GatewayRunner(resolved_config)+ from gateway.run_runtime import initialize_gateway_runtime+ await initialize_gateway_runtime(runner)+ # Multiplex: swap the launch-home file handlers for per-profile routers so each profile's records+ # land in its own logs/. Must run after the runner resolved (possibly None) config and setup_logging.+ # See #82936.+ _enable_multiplex_log_routing(runner.config)+ # ``--replace`` is explicit startup authority, not a durable reconnect policy: GatewayRunner scopes+ # it to cold adapter connects and clears it before the background reconnect watcher starts.+ runner._platform_lock_takeover_on_start = bool(replace)++ # Unexpected signals exit non-zero so service managers revive us; planned stops write a marker first.+ _signal_initiated_shutdown = [False]++ shutdown_signal_handler = _start_gateway_make_shutdown_signal_handler(+ runner, _signal_initiated_shutdown)++ def restart_signal_handler():+ runner.request_restart(detached=False, via_service=True)++ loop = asyncio.get_running_loop()++ # Swallow transient network errors from background tasks; one unhandled httpx error would kill us.+ # Issues #31066 / #31110: an unhandled ``telegram.error.TimedOut`` (or peer NetworkError / httpx+ # connection error) in any awaited coroutine would propagate to the loop and kill the gateway process,+ # taking down every profile attached to the same runner. systemd then restarts the service after ~5s but+ # the active conversation turn is lost. The fix is intentionally narrow: only well-known transient+ # network errors are swallowed (and logged with full traceback so the originating call site is still+ # discoverable). Anything else is forwarded to the default handler so real bugs still surface.+ loop.set_exception_handler(_gateway_loop_exception_handler)++ if threading.current_thread() is threading.main_thread():+ # add_signal_handler raises NotImplementedError on Windows; SIGUSR1 is POSIX-only.+ handlers = [(sig, shutdown_signal_handler, (sig,)) for sig in (signal.SIGINT, signal.SIGTERM)]+ if hasattr(signal, "SIGUSR1"):+ handlers.append((signal.SIGUSR1, restart_signal_handler, ())) # windows-footgun: ok — hasattr-guarded+ for sig, handler, args in handlers:+ with suppress(NotImplementedError):+ loop.add_signal_handler(sig, handler, *args) # windows-footgun: ok — suppress(NotImplementedError)+ else:+ logger.info("Skipping signal handlers (not running in main thread).")++ # Windows has no add_signal_handler, so `hermes gateway stop`'s SIGTERM would never drain; poll the+ # planned-stop marker (written BEFORE the kill) instead. Runs everywhere so masked-SIGTERM drains.+ # Windows fallback: asyncio.add_signal_handler raises NotImplementedError on Windows, so `hermes gateway+ # stop`'s SIGTERM (which Python maps to TerminateProcess on Windows) never invokes+ # shutdown_signal_handler. That means the drain loop never runs, mark_resume_pending never fires, and+ # sessions are silently lost across restarts (issue #33778). The fix is a marker-polling thread: `hermes+ # gateway stop` writes the planned-stop marker BEFORE killing, and this thread notices it and drives the+ # same shutdown path the signal handler would have. Runs on every platform (cheap, defensive) so+ # non-signal-bearing environments (Windows native, sandboxed CI runners that mask SIGTERM) still get a+ # clean drain.+ _planned_stop_watcher_stop = threading.Event()+ _planned_stop_watcher_thread = threading.Thread(+ target=_run_planned_stop_watcher,+ args=(_planned_stop_watcher_stop, runner, loop, shutdown_signal_handler), daemon=True,+ name="planned-stop-watcher")+ _planned_stop_watcher_thread.start()++ # Right after the PID claim (which makes us authoritative); non-fatal — consumers fall back to scan.+ _control_server = await _start_gateway_start_control_socket(runner)+ if _control_server is None:+ raise RuntimeError("gateway session bootstrap control listener unavailable")+ from gateway.run_runtime import start_gateway_runtime_api+ await start_gateway_runtime_api(runner)++ def _lifecycle_record_startup() -> None:+ # Report if the previous life died uncleanly (SIGKILL / OOM / VM death), then claim the+ # sentinel for this life. After the PID-file claim so a --replace loser can't clobber it.+ from gateway.lifecycle_ledger import record_startup+ record_startup()++ def _start_keepalive() -> None:+ from hermes_cli.nous_auth_keepalive import start_nous_auth_keepalive+ start_nous_auth_keepalive()++ _best_effort(_lifecycle_record_startup, "Lifecycle ledger startup record failed: %s")+ _best_effort(_start_keepalive, "Nous auth keepalive did not start: %s")+ _ensure_windows_gateway_venv_imports()++ # discover_mcp_tools() blocks up to 120s; on the loop thread it would freeze platform heartbeats.+ try:+ # MCP tool discovery — run in an executor so the asyncio event loop stays responsive even when a+ # configured MCP server is slow or unreachable. discover_mcp_tools() uses a blocking 120s wait+ # internally; calling it from the loop thread would freeze platform heartbeats (Discord shard,+ # Telegram polling) until it returned. See #16856.+ await _discover_gateway_mcp_tools(runner.config)+ except Exception as e:+ logger.debug("MCP tool discovery failed: %s", e)++ try:+ success = await runner.start()+ except BaseException:+ _shutdown_gateway_health_export(runner)+ raise+ if not success:+ _shutdown_gateway_health_export(runner)+ return False++ def _recover_pending() -> None:+ from gateway.shutdown_flush import recover_pending_to_db+ recovered = recover_pending_to_db()+ if recovered:+ logger.info("Recovered %d pending message(s) from shutdown flush", recovered)++ _best_effort(_recover_pending)+ if runner.should_exit_cleanly:+ _shutdown_gateway_health_export(runner)+ if runner.exit_reason:+ logger.error("Gateway exiting cleanly: %s", runner.exit_reason)+ # Explicit exit codes (GATEWAY_FATAL_CONFIG_EXIT_CODE) must propagate so s6 finish maps 78 → 125.+ if runner.exit_code is not None:+ raise SystemExit(runner.exit_code)+ return True+ if not runner._running:+ # Startup aborted by restart/shutdown before running mode; preserve that path without starting cron.+ try:+ await runner.wait_for_shutdown()+ with suppress(Exception):+ await _shutdown_mcp_servers_nonblocking()+ return _resolve_gateway_exit_verdict(runner, _signal_initiated_shutdown[0])+ finally:+ _shutdown_gateway_health_export(runner)++ cron_stop, cron_provider, cron_thread, housekeeping_thread = (+ _start_gateway_start_cron_and_housekeeping(runner))++ # READY only once adapters, cron and housekeeping run; missing systemd state just disables watchdog.+ from gateway.run_runtime import publish_gateway_runtime_ready+ publish_gateway_runtime_ready(runner)+ runner._start_systemd_watchdog()++ from gateway.run_runtime import wait_gateway_runtime+ try:+ await wait_gateway_runtime(runner)+ finally:+ try:+ await runner.stop()+ finally:+ verdict = await _start_gateway_shutdown_tail(+ runner, _control_server, cron_stop, cron_provider, cron_thread, housekeeping_thread,+ _planned_stop_watcher_stop, _planned_stop_watcher_thread, _signal_initiated_shutdown)+ return verdict++ finally:+ try:+ if runner is not None:+ from gateway.run_runtime import drain_gateway_runtime+ await drain_gateway_runtime(runner)+ # Startup may have opened adapters before an exception. The same+ # stop path owns their writers and DB handles on every exit.+ await runner.stop()+ finally:+ if _planned_stop_watcher_stop is not None:+ _planned_stop_watcher_stop.set()+ if _control_server is not None:+ await _control_server.stop()+ remove_pid_file()+ release_gateway_runtime_lock()