The agent that grows with you
Python aiai-agentai-agentsanthropicchatgptclaudeclaude-codecodexhermeshermes-agentllmnous-researchopenai
fix(doctor): name the processes holding a WAL database that journal_mode=delete never converted
teknium1d7ebee3c02ba
diff --git a/hermes_cli/doctor_platform.py b/hermes_cli/doctor_platform.pyindex 5a4df2670db..33fb7fccadd 100644--- a/hermes_cli/doctor_platform.py+++ b/hermes_cli/doctor_platform.py@@ -89,6 +89,37 @@ def _format_db_size(db_path: Path) -> str:return "size unknown"+def _report_database_holders(name: str, db_path: Path) -> None:+ """Name the processes holding ``db_path`` (or a WAL sidecar) so the operator knows what to stop before the+ offline journal-mode conversion; a partial or unavailable scan is reported as "cannot prove quiet", never as+ an all-clear (the scan is the same fail-closed authority repair/VACUUM/checkpoint admission uses)."""+ from hermes_state_holders import _read_proc_argv, foreign_state_db_holders, psutil+ if sys.platform == "win32":+ check_warn(f"{name}: cannot prove the database is quiet", "(holder scan is unavailable on Windows)")+ return+ unknown: list[str] = []+ by_pid: dict[int, set[str]] = {}+ for pid, target in foreign_state_db_holders(db_path):+ if pid <= 0 or target.startswith("uninspectable"):+ unknown.append(target)+ else:+ by_pid.setdefault(pid, set()).add(Path(target.removesuffix(" (deleted)")).name)+ for pid in sorted(by_pid):+ argv = _read_proc_argv(pid) # /proc only; macOS holders come from psutil+ if argv is None and psutil is not None:+ try:+ argv = psutil.Process(pid).cmdline() or None+ except Exception:+ argv = None+ who = " ".join([Path(argv[0]).name, *argv[1:]])[:80] if argv else "command line unavailable"+ check_info(f"{name} is held by PID {pid} ({who}): {', '.join(sorted(by_pid[pid]))}")+ if unknown:+ check_warn(f"{name}: cannot prove the database is quiet",+ f"(holder scan incomplete: {unknown[0][:120]}" + (f"; +{len(unknown) - 1} more" if len(unknown) > 1 else "") + ")")+ elif not by_pid:+ check_info(f"{name}: no other process holds it right now — the offline conversion can run")++def _report_database_journal_modes(hermes_home: Path | None = None, version_info: tuple[int, ...] | None = None) -> None:"""List each database's journal mode; warn on WAL under a vulnerable SQLite, and on a configured``database.journal_mode: delete`` that never took effect."""@@ -122,6 +153,7 @@ def _report_database_journal_modes(hermes_home: Path | None = None, version_info+ ("; also exposed to the WAL-reset bug" if vulnerable else "")+ ". Stop every Hermes process for this profile, then run a one-time offline ""'PRAGMA journal_mode=DELETE' on the file)")+ _report_database_holders(name, path)elif error is not None:if vulnerable:check_warn(f"{name}: journal mode could not be read", f"({error}; cannot rule out WAL exposure)")diff --git a/tests/hermes_cli/test_doctor_journal_modes.py b/tests/hermes_cli/test_doctor_journal_modes.pyindex d0e19f3a901..b208a3a2ef1 100644--- a/tests/hermes_cli/test_doctor_journal_modes.py+++ b/tests/hermes_cli/test_doctor_journal_modes.py@@ -10,6 +10,8 @@ read-only engine open creates -wal/-shm sidecar files next to a WAL database.import osimport reimport sqlite3+import subprocess+import sysimport pytest@@ -461,6 +463,43 @@ class TestConfiguredDeleteNeverApplied:assert "state.db: WAL journal mode" not in outassert ("To clear the exposure:" in out) is exposed+ @pytest.mark.skipif(sys.platform == "win32", reason="holder scan has no Windows backend")+ def test_wal_db_under_configured_delete_names_its_holders(self, tmp_path, capsys, monkeypatch):+ # The offline conversion needs the file quiet, so doctor must say WHICH process to stop — a+ # subprocess holding a real connection is named by PID; the doctor process itself is not a holder.+ db = tmp_path / "state.db"+ _make_db(db, journal_mode="WAL")+ monkeypatch.setattr("hermes_state_wal.resolve_journal_mode", lambda: "delete")+ holder = subprocess.Popen(+ [sys.executable, "-c",+ "import sqlite3, sys; c = sqlite3.connect(sys.argv[1]); c.execute('SELECT count(*) FROM t'); "+ "print('ready', flush=True); sys.stdin.readline()", str(db)],+ stdin=subprocess.PIPE, stdout=subprocess.PIPE, text=True,+ )+ try:+ assert holder.stdout.readline().strip() == "ready"+ doctor_platform._report_database_journal_modes(tmp_path, (3, 51, 3))+ finally:+ holder.stdin.write("\n")+ holder.stdin.flush()+ holder.wait(timeout=30)++ out = capsys.readouterr().out+ assert f"state.db is held by PID {holder.pid}" in out and "state.db" in out.split("held by PID")[1]+ assert "no other process holds it" not in out and "cannot prove" not in out++ def test_partial_holder_scan_is_never_an_all_clear(self, tmp_path, capsys, monkeypatch):+ _make_db(tmp_path / "state.db", journal_mode="WAL")+ monkeypatch.setattr("hermes_state_wal.resolve_journal_mode", lambda: "delete")+ monkeypatch.setattr("hermes_state_holders.foreign_state_db_holders",+ lambda path: [(-1, "open-file scan unavailable")])++ doctor_platform._report_database_journal_modes(tmp_path, (3, 51, 3))++ out = capsys.readouterr().out+ assert "cannot prove the database is quiet" in out and "open-file scan unavailable" in out+ assert "no other process holds it" not in out and "held by PID" not in out+def test_configured_wal_keeps_the_informational_line(self, tmp_path, capsys, monkeypatch):_make_db(tmp_path / "state.db", journal_mode="WAL")monkeypatch.setattr("hermes_state_wal.resolve_journal_mode", lambda: "wal")diff --git a/website/docs/user-guide/configuration.md b/website/docs/user-guide/configuration.mdindex 5b0e5bdda0e..4ad47a51ce9 100644--- a/website/docs/user-guide/configuration.md+++ b/website/docs/user-guide/configuration.md@@ -127,7 +127,10 @@ mode is not live-downgraded when you set `journal_mode: delete` (a downgradeunder open connections can corrupt it). `hermes doctor` warns`<db> is in WAL mode despite database.journal_mode=delete` until you stopevery Hermes process for the profile and run a one-time offline-`PRAGMA journal_mode=DELETE` on the file.+`PRAGMA journal_mode=DELETE` on the file. Under that warning it names the+processes currently holding the database (`<db> is held by PID <n> (<command>)`)+so you know what to stop; when the holder scan is partial or unavailable it says+`cannot prove the database is quiet` instead of giving an all-clear.## Environment Variable Substitution