The agent that grows with you
Python aiai-agentai-agentsanthropicchatgptclaudeclaude-codecodexhermeshermes-agentllmnous-researchopenai
feat(gateway): HermesGateway service verbs + updater Restart-Service + docs
ethernete6c7d4a55505
diff --git a/hermes_cli/config_defaults.py b/hermes_cli/config_defaults.pyindex 2e64ec06e68..fe123155e6a 100644--- a/hermes_cli/config_defaults.py+++ b/hermes_cli/config_defaults.py@@ -3212,6 +3212,13 @@ DEFAULT_CONFIG = {# the historical serve-all behavior; [] serves only the default."multiplex_profile_allowlist": None,+ # The MSIX HermesGateway Windows Service posture (windows MSIX+ # installs only; see `hermes gateway service on|off|status`).+ # False = the service exists but stays demand-start/stopped+ # (config-only posture — settled 2026-09-03); True = automatic+ # at logon, bots keep running without the desktop app.+ "service": False,+# After an unexpected SIGTERM interrupts a running gateway agent,# wait this many seconds for it to unwind before adapter and database# teardown proceeds. Keep this short so service-manager shutdowns dodiff --git a/hermes_cli/gateway.py b/hermes_cli/gateway.pyindex ed62747bd8a..28fe339b47d 100644--- a/hermes_cli/gateway.py+++ b/hermes_cli/gateway.py@@ -1235,6 +1235,12 @@ def _prepare_profile_gateway_update_restart(profile: str, pid: int) -> str | Nonmanager and race its replacement process. Ordinary foreground gatewaysretain the existing detached-watcher behavior.+ A sealed MSIX install whose HermesGateway Windows Service is running+ has a service manager for this: the SCM restarts the service+ (graceful-stop → respawn — drain-first by construction, the frontend's+ STOP writes the planned-stop marker). Restart-Service is the whole+ dance; arming a detached watcher beside it would double-spawn.+When the profile-derived relaunch cannot be armed -- typically because``_gateway_run_args_for_profile`` cannot rebuild a run argv for thisprofile -- fall back to replaying the process's own captured command@@ -1243,8 +1249,12 @@ def _prepare_profile_gateway_update_restart(profile: str, pid: int) -> str | Nonunmapped gateways. Without this the caller has no way to relaunch theprocess and (before #88654) silently left it running pre-update modulesagainst post-update code on disk. ``argv`` is already captured above,- so the fallback costs nothing extra.+ so the fallback costs nothing."""+ # The SCM owns restarts on a service-managed sealed install (#D6b+ # windows half): Restart-Service, no watcher, no scan.+ if _try_scm_service_restart():+ return "scm-service"argv = _capture_gateway_argv(pid)if argv and "--external-supervisor" in argv:return "external-supervisor"@@ -1255,6 +1265,39 @@ def _prepare_profile_gateway_update_restart(profile: str, pid: int) -> str | Nonreturn None+def _try_scm_service_restart() -> bool:+ """Restart the HermesGateway Windows Service when it's the running+ gateway's manager: sealed MSIX install + service present + running.++ Returns True when the SCM restart was issued (the caller must NOT arm+ a detached watcher); False on any other machine shape (source+ installs, service absent or stopped — the normal paths apply).+ """+ if sys.platform != "win32":+ return False+ try:+ import win32serviceutil+ except ImportError:+ return False+ try:+ from gateway.windows_service import SERVICE_NAME+ from pm.ensure import sealed++ if not sealed():+ return False+ status = win32serviceutil.QueryServiceStatus(SERVICE_NAME)+ running = bool(status and status[1] == 4) # SERVICE_RUNNING+ if not running:+ return False+ win32serviceutil.RestartService(SERVICE_NAME)+ print(f" ⏻ Restarting {SERVICE_NAME} service (graceful drain → respawn)")+ return True+ except Exception:+ # Not service-managed (most installs): the ordinary restart paths+ # own it. Never fail the update over a service lookup.+ return False++def launch_detached_gateway_restart_by_cmdline(old_pid: int, run_argv: list[str]) -> bool:@@ -4483,6 +4526,106 @@ def _ensure_linger_enabled() -> None:_print_linger_enable_warning(username, detail or linger_detail)+def _windows_scm_service_command(action: str | None) -> None:+ """`hermes gateway service on|off|status` — the MSIX HermesGateway+ Windows Service (SCM-registered at MSIX install, demand-start;+ plan: gateway-msix-windows-service, Task 5; config-only posture).++ "on" = automatic-at-logon + start now (persisted via gateway.service).+ "off" = demand-start + stop now.+ "status" = SCM state + the config key.+ """+ if sys.platform != "win32":+ print_error("`hermes gateway service` manages the MSIX HermesGateway "+ "Windows Service — not available on this platform.")+ return+ try:+ import win32service+ import win32serviceutil+ except ImportError:+ print_error("pywin32 is required for service management.")+ return++ from gateway.windows_service import SERVICE_NAME++ def _config_get() -> bool:+ try:+ from hermes_cli.config import get_config_value++ return bool(get_config_value("gateway.service", False))+ except Exception:+ return False++ def _scm_status() -> tuple[bool, str]:+ """(installed, state-name) — service absent = (False, 'not installed')."""+ try:+ status = win32serviceutil.QueryServiceStatus(SERVICE_NAME)+ states = {+ 1: "stopped",+ 2: "start pending",+ 3: "stop pending",+ 4: "running",+ 5: "continue pending",+ 6: "pause pending",+ 7: "paused",+ }+ return True, states.get(status[1], f"unknown ({status[1]})")+ except Exception:+ return False, "not installed"++ if action in (None, "status"):+ installed, state = _scm_status()+ enabled = _config_get()+ print(f"HermesGateway service: {state}" if installed else+ "HermesGateway service: not installed (MSIX bundles only)")+ print(f" config gateway.service: {'on' if enabled else 'off'}")+ if installed and state == "running" and not enabled:+ print_warning("service is running but the config key is off — "+ "run `hermes gateway service on` to persist")+ return++ if action == "on":+ installed, _ = _scm_status()+ if not installed:+ print_error("HermesGateway service is not installed — it ships "+ "with the MSIX bundle (desktop app install).")+ return+ try:+ # Automatic at logon + start now, gracefully.+ win32serviceutil.ChangeServiceConfig(+ SERVICE_NAME, starttype=win32service.SERVICE_AUTO_START+ )+ win32serviceutil.StartService(SERVICE_NAME)+ from cli import save_config_value++ save_config_value("gateway.service", True)+ print(f"✓ {SERVICE_NAME}: automatic at logon + starting now")+ print(" Bots keep running without the desktop app.")+ except Exception as exc:+ print_error(f"Could not enable service: {exc}")+ return++ if action == "off":+ installed, _ = _scm_status()+ if not installed:+ print_error("HermesGateway service is not installed.")+ return+ try:+ win32serviceutil.ChangeServiceConfig(+ SERVICE_NAME, starttype=win32service.SERVICE_DEMAND_START+ )+ win32serviceutil.StopService(SERVICE_NAME) # graceful: frontend marker path+ from cli import save_config_value++ save_config_value("gateway.service", False)+ print(f"✓ {SERVICE_NAME}: demand-start + stopping (graceful drain)")+ except Exception as exc:+ print_error(f"Could not disable service: {exc}")+ return++ print_error(f"Unknown service action: {action!r} (on|off|status)")++def _select_systemd_scope(system: bool = False) -> bool:if system:return True@@ -9050,6 +9193,9 @@ def _gateway_command_inner(args):print("Starting gateway...")run_gateway(verbose=0)+ elif subcmd == "service":+ _windows_scm_service_command(getattr(args, "gateway_service_action", None))+elif subcmd == "status":deep = getattr(args, "deep", False)full = getattr(args, "full", False)diff --git a/hermes_cli/subcommands/gateway.py b/hermes_cli/subcommands/gateway.pyindex 7092e8f09f6..75b7675d14d 100644--- a/hermes_cli/subcommands/gateway.py+++ b/hermes_cli/subcommands/gateway.py@@ -170,6 +170,21 @@ def build_gateway_parser()_add_compat_platform_flag(gateway_status)+ # gateway service (MSIX HermesGateway Windows Service — the SCM one)+ gateway_service = gateway_subparsers.add_parser(+ "service",+ help="Manage the HermesGateway Windows Service (MSIX installs)",+ description=(+ "The bundled MSIX installs a HermesGateway Windows Service "+ "(demand-start, stopped). 'on' = automatic at logon + start "+ "now; 'off' = demand + stop; 'status' = SCM state + config."+ ),+ )+ gateway_service_sub = gateway_service.add_subparsers(dest="gateway_service_action")+ gateway_service_sub.add_parser("on", help="Enable: automatic at logon + start now")+ gateway_service_sub.add_parser("off", help="Disable: demand-start + stop now")+ gateway_service_sub.add_parser("status", help="Show SCM state + config key")+# gateway installgateway_install = gateway_subparsers.add_parser("install", help="Install gateway as a systemd/launchd background service"diff --git a/tests/hermes_cli/test_gateway_scm_service.py b/tests/hermes_cli/test_gateway_scm_service.pynew file mode 100644index 00000000000..4149331cf4f--- /dev/null+++ b/tests/hermes_cli/test_gateway_scm_service.py@@ -0,0 +1,142 @@+"""Tests: `hermes gateway service` verbs + the updater's SCM restart branch.++Hermetic — pywin32/SCM calls stubbed; the CONTRACTS are what's tested:+dispatch, config persistence, the sealed+running gate for the updater's+Restart-Service path, and the fall-through to ordinary restarts on every+other machine shape.+"""++from __future__ import annotations++from unittest.mock import patch++import pytest++import hermes_cli.gateway as gw+++def _fake_scm(monkeypatch, *, installed=True, running=True, calls=None):+ """Stub the pywin32 SCM surface; record calls into `calls`."""+ import sys+ import types++ if calls is None:+ calls = []+ mod = types.ModuleType("win32service")+ mod.SERVICE_AUTO_START = 2+ mod.SERVICE_DEMAND_START = 3+ util_mod = types.ModuleType("win32serviceutil")+ util_mod.QueryServiceStatus = lambda name: (None, 4 if running else 1) if installed else (_ for _ in ()).throw(OSError("not installed"))+ util_mod.ChangeServiceConfig = lambda name, starttype: calls.append(("config", starttype))+ util_mod.StartService = lambda name: calls.append(("start",))+ util_mod.StopService = lambda name: calls.append(("stop",))+ util_mod.RestartService = lambda name: calls.append(("restart",))+ monkeypatch.setitem(sys.modules, "win32service", mod)+ monkeypatch.setitem(sys.modules, "win32serviceutil", util_mod)+ return calls+++def test_service_status_not_installed(monkeypatch, capfd):+ monkeypatch.setattr(gw.sys, "platform", "win32")+ import sys as _sys++ _sys.modules.pop("win32service", None)+ _sys.modules.pop("win32serviceutil", None)++ import types++ mod = types.ModuleType("win32service")+ mod.SERVICE_AUTO_START = 2+ mod.SERVICE_DEMAND_START = 3+ util_mod = types.ModuleType("win32serviceutil")++ def boom(name):+ raise OSError("not installed")++ util_mod.QueryServiceStatus = boom+ monkeypatch.setitem(_sys.modules, "win32service", mod)+ monkeypatch.setitem(_sys.modules, "win32serviceutil", util_mod)++ gw._windows_scm_service_command(None)+ out = capfd.readouterr().out+ assert "not installed" in out+++def test_service_on_configures_starts_persists(monkeypatch, capfd):+ monkeypatch.setattr(gw.sys, "platform", "win32")+ calls = _fake_scm(monkeypatch, installed=True, running=True)+ saved = {}+ monkeypatch.setattr("cli.save_config_value", lambda k, v: saved.update({k: v}))++ gw._windows_scm_service_command("on")+ assert ("config", 2) in calls # SERVICE_AUTO_START+ assert ("start",) in calls+ assert saved == {"gateway.service": True}+ assert "automatic at logon" in capfd.readouterr().out+++def test_service_off_demand_stops_persists(monkeypatch, capfd):+ monkeypatch.setattr(gw.sys, "platform", "win32")+ calls = _fake_scm(monkeypatch, installed=True, running=True)+ saved = {}+ monkeypatch.setattr("cli.save_config_value", lambda k, v: saved.update({k: v}))++ gw._windows_scm_service_command("off")+ assert ("config", 3) in calls # SERVICE_DEMAND_START+ assert ("stop",) in calls+ assert saved == {"gateway.service": False}+++def test_service_unknown_action_is_an_error(monkeypatch, capfd):+ monkeypatch.setattr(gw.sys, "platform", "win32")+ calls = _fake_scm(monkeypatch, installed=True, running=True)+ monkeypatch.setattr("cli.save_config_value", lambda k, v: None)+ gw._windows_scm_service_command("dance")+ assert "Unknown service action" in capfd.readouterr().out+++# ── the updater's SCM restart branch ─────────────────────────────────+++def test_updater_scm_restart_gated_on_running_service(monkeypatch):+ """Sealed + HermesGateway RUNNING → Restart-Service, True (skip the+ detached watcher); any other shape → False (ordinary paths)."""+ monkeypatch.setattr(gw.sys, "platform", "win32")+ calls = _fake_scm(monkeypatch, installed=True, running=True)++ import importlib+ import sys++ sys.modules.pop("pm.ensure", None)+ pm_ensure = importlib.import_module("pm.ensure")++ monkeypatch.setattr(pm_ensure, "sealed", lambda: True)++ assert gw._try_scm_service_restart() is True+ assert ("restart",) in calls+++def test_updater_scm_restart_false_when_not_sealed(monkeypatch):+ monkeypatch.setattr(gw.sys, "platform", "win32")+ calls = _fake_scm(monkeypatch, installed=True, running=True)+ import importlib++ pm_ensure = importlib.import_module("pm.ensure")+ monkeypatch.setattr(pm_ensure, "sealed", lambda: False)+ assert gw._try_scm_service_restart() is False+ assert calls == [] # no SCM touch+++def test_updater_scm_restart_false_when_service_stopped(monkeypatch):+ monkeypatch.setattr(gw.sys, "platform", "win32")+ calls = _fake_scm(monkeypatch, installed=True, running=False)+ import importlib++ pm_ensure = importlib.import_module("pm.ensure")+ monkeypatch.setattr(pm_ensure, "sealed", lambda: True)+ assert gw._try_scm_service_restart() is False+++def test_updater_scm_restart_false_on_posix(monkeypatch):+ monkeypatch.setattr(gw.sys, "platform", "linux")+ assert gw._try_scm_service_restart() is Falsediff --git a/website/docs/user-guide/features/gateway-service.md b/website/docs/user-guide/features/gateway-service.mdnew file mode 100644index 00000000000..fc4eba1fcd4--- /dev/null+++ b/website/docs/user-guide/features/gateway-service.md@@ -0,0 +1,68 @@+# Gateway Service++The messaging gateway (Telegram, Discord, WhatsApp, and every other+platform adapter) normally runs as a child of wherever you started it —+a terminal, `hermes serve`, or the desktop app's backend. On Windows,+the **bundled MSIX install** ships one more way: a real Windows Service.++## What it is++Installing the desktop app registers a service named **HermesGateway**+in the Windows Service Control Manager. It arrives **stopped** and+**demand-start** — it never starts on its own. When you turn it on, the+Service Control Manager owns the gateway's lifecycle:++- **automatic at logon** — bots start when you sign in, no app needed+- **restart on crash** — the SCM respawns the gateway if it dies+- **bots survive app close** — the service is not the desktop app's+ child; closing the app never touches it++The service runs as *you* (the installing user), using your Hermes home+— the same sessions, memory, and config as every other surface. The+default profile's gateway is what it serves; multiplexed profiles ride+the same process, exactly as a foreground gateway.++## Turning it on++```bash+hermes gateway service on+```++That flips the service to automatic-at-logon and starts it now,+gracefully. Turning it off is the same shape:++```bash+hermes gateway service off # demand-start + graceful stop+hermes gateway service status # SCM state + the config key+```++The posture persists in the `gateway.service` config key, so `hermes+gateway service status` is the one command that answers "is this on?"++## Updates and the graceful stop++Stopping the service — by you, by an update, or by Windows shutdown —+is always graceful: in-flight agent sessions drain, the session database+flushes, and platform locks release (the same drain path `hermes+gateway stop` uses). `hermes update` on a service-managed install+restarts the service through the SCM (`Restart-Service`) — the drain+happens first, the respawn after, so a mixed-version gateway is never+left serving.++## Uninstall++Uninstalling the desktop app removes the service automatically (MSIX+registers it; MSIX removes it). Bots stop — same as today, where+uninstalling the payload removes the gateway's runtime.++## Platform notes++- **Windows MSIX installs only.** Source installs (and every other+ platform) keep the foreground `hermes gateway run`, systemd, or+ launchd paths — see [the CLI gateway+ docs](/user-guide/cli#gateway).+- The service requires Windows 10 1903+ (the MSIX's minimum OS — the+ same floor the desktop app ships with).+- `services.msc` shows it as "Hermes Gateway"; manage it there if you+ like, though the `hermes gateway service` verbs keep the config key+ in sync, which the SCM console does not.diff --git a/website/sidebars.ts b/website/sidebars.tsindex eba4ad2e92f..38f8c2f76e5 100644--- a/website/sidebars.ts+++ b/website/sidebars.ts@@ -68,6 +68,7 @@ const sidebars: SidebarsConfig = {items: ['user-guide/features/overview','user-guide/features/tool-gateway',+ 'user-guide/features/gateway-service',{type: 'category',label: 'Core',