Skip to content

The agent that grows with you

fix: require an unambiguous baseline for successor-credited gateway restarts

DavidMetcalfef42fd748c809
diff --git a/hermes_cli/update_inventory.py b/hermes_cli/update_inventory.py
index c5c17adea65..10a5474e9bf 100644
--- a/hermes_cli/update_inventory.py
+++ b/hermes_cli/update_inventory.py
@@ -419,6 +419,12 @@ def match_runtime_outcomes(
answers for the same profile counts as ``restarted``. A missing successor, or the planned PID
still answering, stays ``unaccounted`` — the tripwire keeps its teeth.
+ That credit needs an unambiguous baseline: a profile with SEVERAL planned gateway runtimes cannot
+ be attributed to one successor (the fleet probe publishes at most one row per profile), so one
+ replacement cannot have replaced two planned processes. Such a profile keeps the name-path
+ verdict instead of letting an untouched sibling vanish behind a successor that can only have
+ replaced one of them.
+
See #91277.
They never borrow the gateway's outcome: ``relaunched_profiles`` and ``hermes-gateway*`` name a
different process that shares the profile, nothing more. See #100479.
@@ -442,6 +448,12 @@ def match_runtime_outcomes(
if live_gateway_pids is not None
else None
)
+ # Baseline identity: the fleet probe publishes at most one row per profile, so successor
+ # evidence is only attributable when the plan holds ONE gateway runtime for that profile.
+ planned_gateways: dict[str, int] = {}
+ for _planned in plan.runtimes:
+ if isinstance(_planned, RuntimeRecord) and _planned.kind not in _SERVE_KINDS:
+ planned_gateways[_planned.profile] = planned_gateways.get(_planned.profile, 0) + 1
def _outcome(r: RuntimeRecord) -> str:
killed_here = r.pid is not None and r.pid in killed
@@ -477,9 +489,16 @@ def match_runtime_outcomes(
# label/unit may encode the install root (or a hashed home) instead of the served
# profile, which the profile-scoped name matcher above can never credit.
live = successors.get(r.profile)
- if live and r.pid not in live:
+ ambiguous = planned_gateways.get(r.profile, 0) > 1
+ if live and r.pid not in live and not ambiguous:
return "restarted"
- if not live:
+ if ambiguous:
+ logger.debug(
+ "%s planned gateway runtimes for profile %r — one successor cannot attribute "
+ "the restart, leaving pid %s on the name path",
+ planned_gateways[r.profile], r.profile, r.pid,
+ )
+ elif not live:
# No row for this profile: the fallback has nothing to work with and reconciliation
# stays on the service-name path. Logged because the tripwire below reads identically
# whether the evidence was missing or the restart was actually missed.
diff --git a/tests/hermes_cli/test_restart_plan_reconciliation.py b/tests/hermes_cli/test_restart_plan_reconciliation.py
index 457b4d858cc..c2b0f83dd1b 100644
--- a/tests/hermes_cli/test_restart_plan_reconciliation.py
+++ b/tests/hermes_cli/test_restart_plan_reconciliation.py
@@ -508,6 +508,32 @@ def test_live_gateway_pids_from_fleet_skips_down_and_unusable_rows():
assert _live_gateway_pids_from_fleet([]) == {}
+def test_one_successor_cannot_credit_two_planned_runtimes_same_profile():
+ """The fleet probe publishes at most one row per profile, so one successor cannot
+ say which of two planned same-profile gateways it replaced. Neither may be
+ credited — otherwise an untouched sibling disappears behind a replacement that
+ can only have replaced one of them, and the tripwire is suppressed."""
+ outcomes = match_runtime_outcomes(
+ _plan(_rt("coder", 76508, supervisor="launchd"), _rt("coder", 76795, supervisor="launchd")),
+ restarted_services=[], relaunched_profiles=[], externally_supervised_profiles=[],
+ killed_pids=set(), failed_units=[], live_gateway_pids={"coder": {76796}},
+ )
+ assert [o["outcome"] for o in outcomes] == ["unaccounted", "unaccounted"]
+ assert report_unaccounted_runtimes(outcomes) is True
+
+
+def test_successor_credit_stays_per_profile_with_several_planned_runtimes():
+ """The ambiguity guard is per profile: two profiles with one planned runtime each
+ are both credited from their own successor."""
+ outcomes = match_runtime_outcomes(
+ _plan(_rt("coder", 76508, supervisor="launchd"), _rt("work", 401, supervisor="launchd")),
+ restarted_services=[], relaunched_profiles=[], externally_supervised_profiles=[],
+ killed_pids=set(), failed_units=[],
+ live_gateway_pids={"coder": {76796}, "work": {402}},
+ )
+ assert [o["outcome"] for o in outcomes] == ["restarted", "restarted"]
+
+
def test_successor_evidence_is_gateway_only_and_stays_optional():
"""Serve/dashboard rows reconcile in their own vocabulary, and callers that