Skip to content

The agent that grows with you

fix(cli): name the dashboard kill grace and pin it against the lifespan teardown

teknium1f93d33f93f93
diff --git a/hermes_cli/dashboard_procs.py b/hermes_cli/dashboard_procs.py
index a4ee5552910..b8a7eed7115 100644
--- a/hermes_cli/dashboard_procs.py
+++ b/hermes_cli/dashboard_procs.py
@@ -278,8 +278,18 @@ def _kill_pids_windows(pids: list[int], killed: list[int], failed: list[tuple[in
failed.append((pid, str(e)))
+# SIGTERM → SIGKILL grace for the dashboard/serve backend. Must outlast the lifespan teardown in
+# hermes_cli/web_server.py::_lifespan: stop_hosted_room_service(timeout=5.0) + the startup-thread
+# join(1.0) + PTY_REGISTRY.close_all() (≤1.5s per attached Chat PTY, serial). A SIGKILL inside
+# that window skips close_all(), so the ui-tui / tui_gateway.entry children outlive the backend
+# and keep the deleted state.db-wal inode open — the next hermes start refuses with a FATAL
+# DeletedWalGenerationError (#111912). The orphan reaper's 1.5s (`_reap_orphaned_desktop_local_serves`)
+# is deliberately shorter: it runs on the Desktop boot path under a 10s ready-probe.
+_POSIX_TERM_GRACE_SECONDS = 10.0
+
+
def _kill_pids_posix(pids: list[int], killed: list[int], failed: list[tuple[int, str]]) -> None:
- """SIGTERM, wait up to ~3s for graceful exit, SIGKILL survivors."""
+ """SIGTERM, wait up to ``_POSIX_TERM_GRACE_SECONDS`` for graceful exit, SIGKILL survivors."""
import signal as _signal
import time as _time
@@ -297,7 +307,7 @@ def _kill_pids_posix(pids: list[int], killed: list[int], failed: list[tuple[int,
for pid in pids:
_send(pid, _signal.SIGTERM)
- deadline = _time.monotonic() + 10.0
+ deadline = _time.monotonic() + _POSIX_TERM_GRACE_SECONDS
pending = [p for p in pids if p not in killed and p not in {f[0] for f in failed}]
while pending and _time.monotonic() < deadline:
_time.sleep(0.1)
diff --git a/tests/hermes_cli/test_dashboard_procs_kill_grace.py b/tests/hermes_cli/test_dashboard_procs_kill_grace.py
new file mode 100644
index 00000000000..fd5345049ef
--- /dev/null
+++ b/tests/hermes_cli/test_dashboard_procs_kill_grace.py
@@ -0,0 +1,100 @@
+"""The dashboard SIGTERM→SIGKILL grace must outlast the lifespan teardown (#111912).
+
+``hermes update`` / ``hermes dashboard --stop`` fall back to ``_kill_pids_posix`` for a
+manually-started backend. Its lifespan teardown blocks on ``stop_hosted_room_service(timeout=5.0)``
+before ``PTY_REGISTRY.close_all()`` runs; a SIGKILL inside that window orphans the ui-tui /
+tui_gateway.entry children, which keep the deleted ``state.db-wal`` inode open until the next
+start aborts with ``DeletedWalGenerationError``. Real child processes, real signals.
+"""
+
+from __future__ import annotations
+
+import signal
+import subprocess
+import sys
+import textwrap
+import time
+
+import pytest
+
+from hermes_cli import dashboard_procs
+
+pytestmark = pytest.mark.skipif(sys.platform == "win32", reason="POSIX signal semantics only")
+
+# Mirrors the lifespan: sleep for the teardown budget on SIGTERM, then leave a marker and exit 0.
+_GRACEFUL_CHILD = textwrap.dedent(
+ """
+ import pathlib, signal, sys, time
+ marker, ready, secs = pathlib.Path(sys.argv[1]), pathlib.Path(sys.argv[2]), float(sys.argv[3])
+ def _on_term(_signum, _frame):
+ time.sleep(secs)
+ marker.write_text("teardown-complete")
+ sys.exit(0)
+ signal.signal(signal.SIGTERM, _on_term)
+ ready.write_text("ready")
+ time.sleep(300)
+ """
+)
+
+_IGNORING_CHILD = textwrap.dedent(
+ """
+ import pathlib, signal, sys, time
+ signal.signal(signal.SIGTERM, signal.SIG_IGN)
+ pathlib.Path(sys.argv[1]).write_text("ready")
+ time.sleep(300)
+ """
+)
+
+
+def _spawn_ready(script: str, ready_path, *args: str) -> subprocess.Popen:
+ child = subprocess.Popen(
+ [sys.executable, "-c", script, *args],
+ stdin=subprocess.DEVNULL, stdout=subprocess.DEVNULL, stderr=subprocess.DEVNULL,
+ )
+ deadline = time.monotonic() + 10.0
+ while not ready_path.exists(): # the SIGTERM handler must be installed before we signal
+ if child.poll() is not None:
+ raise AssertionError(f"child exited before signaling ready: {child.returncode}")
+ if time.monotonic() > deadline:
+ raise AssertionError("child never signaled ready")
+ time.sleep(0.02)
+ return child
+
+
+def _kill_and_reap(child: subprocess.Popen):
+ killed: list[int] = []
+ failed: list[tuple[int, str]] = []
+ dashboard_procs._kill_pids_posix([child.pid], killed, failed)
+ try:
+ child.wait(timeout=10)
+ finally:
+ if child.poll() is None:
+ child.kill()
+ child.wait(timeout=10)
+ return killed, failed
+
+
+def test_teardown_as_long_as_lifespan_budget_exits_gracefully(tmp_path):
+ """A teardown spanning the 5s hosted-room stop + 1s join must not be SIGKILLed."""
+ marker, ready = tmp_path / "marker", tmp_path / "ready"
+ child = _spawn_ready(_GRACEFUL_CHILD, ready, str(marker), str(ready), "6.2")
+
+ killed, failed = _kill_and_reap(child)
+
+ assert failed == []
+ assert child.returncode == 0, f"SIGKILLed mid-teardown (rc={child.returncode})"
+ assert marker.read_text() == "teardown-complete"
+ assert killed == [child.pid]
+
+
+def test_sigterm_ignoring_process_is_still_sigkilled(tmp_path, monkeypatch):
+ """The grace is a ceiling, not a wait: a process that ignores SIGTERM is force-killed."""
+ monkeypatch.setattr(dashboard_procs, "_POSIX_TERM_GRACE_SECONDS", 0.6)
+ ready = tmp_path / "ready"
+ child = _spawn_ready(_IGNORING_CHILD, ready, str(ready))
+
+ killed, failed = _kill_and_reap(child)
+
+ assert failed == []
+ assert child.returncode == -signal.SIGKILL
+ assert killed == [child.pid]