Skip to content

The agent that grows with you

fix(computer-use): doctor and status report a configured cua-driver daemon whose `serve` is not listening

teknium1f9d6d043320c
diff --git a/hermes_cli/subcommands/computer_use.py b/hermes_cli/subcommands/computer_use.py
index ac0d52f4b88..76476aca7dc 100644
--- a/hermes_cli/subcommands/computer_use.py
+++ b/hermes_cli/subcommands/computer_use.py
@@ -54,6 +54,15 @@ def _cu_status(args) -> int:
else:
print(" Run: hermes computer-use install")
return 1
+ rc = 0
+ if sys.platform == "linux": # hand-written daemon units: dead `serve` is invisible to the binary contract (#114748)
+ from tools.computer_use.cua_backend import cua_daemon_listening
+ from tools.computer_use.doctor import cua_daemon_units
+ for _kind, unit, _target, serve, socket in cua_daemon_units():
+ if serve and cua_daemon_listening(path, socket) is False:
+ print(f" ✗ Daemon unit {unit}: no `cua-driver serve` is listening on {socket or 'the default socket'}")
+ print(f" Check: systemctl --user status {unit} (reinstalling the driver does not start it)")
+ rc = 1
try:
st = cua_driver_update_check()
if st and st.get("update_available"):
@@ -67,7 +76,7 @@ def _cu_status(args) -> int:
print(" Refresh to latest: hermes computer-use install --upgrade")
except Exception:
print(" Refresh to latest: hermes computer-use install --upgrade")
- return 0
+ return rc
def _cu_doctor(args) -> None:
diff --git a/tests/tools/test_computer_use_doctor_stale_units.py b/tests/tools/test_computer_use_doctor_stale_units.py
index 6c465554789..60e6623a2d3 100644
--- a/tests/tools/test_computer_use_doctor_stale_units.py
+++ b/tests/tools/test_computer_use_doctor_stale_units.py
@@ -1,4 +1,5 @@
-"""`hermes computer-use doctor` names a daemon unit whose cua-driver Exec target was pruned (#114748).
+"""`hermes computer-use doctor` names a daemon unit whose cua-driver Exec target was pruned, and a configured
+`cua-driver serve` unit whose daemon is not listening (#114748).
Linux has no managed cua-driver autostart, so users hand-write systemd user units / XDG
autostart entries against a concrete ``packages/releases/<version>/`` directory. The installer
@@ -37,10 +38,12 @@ def _fake_health_report_proc() -> MagicMock:
return proc
-def _run_doctor_json(monkeypatch, home):
+def _run_doctor_json(monkeypatch, home, daemon_probe=lambda *_a, **_kw: None):
+ """``daemon_probe`` stands in for ``cua_daemon_listening`` (the Popen double below breaks ``subprocess.run``)."""
monkeypatch.setenv("HOME", str(home))
if "XDG_CONFIG_HOME" in os.environ and not os.environ["XDG_CONFIG_HOME"].startswith(str(home)):
monkeypatch.delenv("XDG_CONFIG_HOME") # the host's own config dir must not leak into the scan
+ monkeypatch.setattr("tools.computer_use.cua_backend.cua_daemon_listening", daemon_probe)
monkeypatch.setattr(doctor, "_read_cli_version", lambda binary, timeout=5.0: "cua-driver 0.28.2")
out = StringIO()
with patch("shutil.which", return_value="/fake/cua-driver"), \
@@ -97,3 +100,36 @@ def test_doctor_is_silent_for_current_and_live_release_references(tmp_path, monk
assert code == 0 and report["overall"] == "ok"
assert not [c for c in report["checks"] if c["name"].startswith("daemon unit")]
+
+
+def _write_current_serve_unit(home):
+ unit_dir = home / ".config" / "systemd" / "user"
+ unit_dir.mkdir(parents=True)
+ (unit_dir / "cua-driver-screenshot.service").write_text(
+ "[Service]\nExecStart=%h/.cua-driver/packages/current/cua-driver serve --socket %h/.cache/cua-driver/cua-driver.sock\n",
+ encoding="utf-8")
+
+
+def test_doctor_fails_a_configured_daemon_unit_whose_serve_is_not_listening(tmp_path, monkeypatch):
+ """#114748: a healthy binary + a dead `serve` daemon used to be reported as ok; the probe runs against the
+ unit's own --socket path (%h expanded), and a reinstall is named as the wrong remedy."""
+ _write_current_serve_unit(tmp_path)
+ probes = []
+
+ code, report = _run_doctor_json(monkeypatch, tmp_path,
+ lambda binary, socket=None, **_kw: probes.append((binary, socket)) or False)
+
+ rows = [c for c in report["checks"] if c["name"] == "daemon (cua-driver-screenshot.service)"]
+ assert code == 1 and report["overall"] == "degraded"
+ assert rows[0]["status"] == "fail" and "no daemon is listening" in rows[0]["message"]
+ assert "reinstall" in rows[0]["hint"]
+ assert probes == [("/fake/cua-driver", str(tmp_path / ".cache" / "cua-driver" / "cua-driver.sock"))]
+
+
+def test_doctor_passes_a_configured_daemon_unit_whose_serve_answers(tmp_path, monkeypatch):
+ _write_current_serve_unit(tmp_path)
+ code, report = _run_doctor_json(monkeypatch, tmp_path, lambda *_a, **_kw: True)
+
+ rows = [c for c in report["checks"] if c["name"] == "daemon (cua-driver-screenshot.service)"]
+ assert code == 0 and report["overall"] == "ok"
+ assert rows[0]["status"] == "pass" and "listening" in rows[0]["message"]
diff --git a/tools/computer_use/cua_backend.py b/tools/computer_use/cua_backend.py
index a93bac895cf..ff64fd8ea67 100644
--- a/tools/computer_use/cua_backend.py
+++ b/tools/computer_use/cua_backend.py
@@ -142,6 +142,19 @@ def _run_driver(driver_cmd: str, *args: str, timeout: float, swallow: Any = ())
return _run_quiet([driver_cmd, *args], timeout=timeout, swallow=swallow, encoding="utf-8",
errors="replace", creationflags=windows_hide_flags(), env=sanitized_cua_driver_env())
+def cua_daemon_listening(driver_cmd: str, socket_path: Optional[str] = None, *, timeout: float = 3.0) -> Optional[bool]:
+ """Socket-level liveness of a ``cua-driver serve`` daemon: ``cua-driver status`` connects to the daemon
+ socket (the driver's default, or ``socket_path``) and exits 0 only when a daemon answers. False when the
+ CLI reports the daemon is not running, None when the probe itself failed (unknown). Never raises.
+ The binary-level runtime contract (``manifest``) cannot see this — a dead daemon looks healthy there (#114748)."""
+ args = ("status", "--socket", socket_path) if socket_path else ("status",)
+ proc = _run_driver(driver_cmd, *args, timeout=timeout, swallow=(OSError, subprocess.SubprocessError))
+ if proc is None:
+ return None
+ if proc.returncode == 0:
+ return True
+ return False if "not running" in f"{proc.stdout}\n{proc.stderr}".lower() else None
+
def _linux_session_locked() -> Optional[bool]:
"""Is the graphical session locked? (Linux; best-effort.) A locked KDE/GNOME session freezes renderers and
half-disables the AX tree, so discovery legitimately returns nothing — which otherwise reads as a driver bug.
diff --git a/tools/computer_use/doctor.py b/tools/computer_use/doctor.py
index 1efe3407aa4..66d2832d4fd 100644
--- a/tools/computer_use/doctor.py
+++ b/tools/computer_use/doctor.py
@@ -30,6 +30,10 @@ _IO_EXC = (OSError, subprocess.TimeoutExpired)
_PRUNED_UNIT_MSG = "Exec targets {target} which no longer exists — a cua-driver upgrade pruned that release directory"
_PRUNED_UNIT_HINT = ("Point the {kind} at ~/.cua-driver/packages/current/cua-driver — `current` survives upgrades; "
"versioned packages/releases/<version>/ dirs are pruned (only the last 5 are kept)")
+_DEAD_DAEMON_MSG = ("{unit} is configured to run `cua-driver serve` but no daemon is listening on {socket} — "
+ "the unit is not running (crash loop, stopped, or never started)")
+_DEAD_DAEMON_HINT = ("Check `systemctl --user status {unit}` / `journalctl --user -u {unit}`; a driver reinstall does not "
+ "start the daemon and cannot fix a broken unit")
Report = Dict[str, Any]
_Row = Tuple[str, str, Report] # (status, message, extra {hint?, data?}) for one check
@@ -284,19 +288,14 @@ def _apply_display_count_guard(report: Report) -> Report:
report["overall"] = "degraded"
return report
-def _stale_cua_exec_references(config_dir: Optional[str] = None) -> List[Tuple[str, str, str]]:
- """(kind, unit, target) for systemd user units / XDG autostart entries whose cua-driver Exec points at a
- pruned ``packages/releases/<version>/`` directory.
-
- Linux has no managed cua-driver autostart (Windows-only), so daemon units are hand-written against a concrete
- release dir. The installer prunes all but the last five, so a versioned reference crash-loops with 203/EXEC
- after every upgrade while every binary-level check stays green (#114748). ``packages/current`` and
- still-present release dirs are healthy by construction and never reported.
- """
- # systemd --user and XDG autostart both honour $XDG_CONFIG_HOME; a host that sets it keeps its units there.
+def cua_daemon_units(config_dir: Optional[str] = None) -> List[Tuple[str, str, str, bool, Optional[str]]]:
+ """(kind, unit, exec_target, runs_serve, --socket path or None) for every systemd user unit / XDG autostart
+ entry whose Exec runs cua-driver — the hand-written daemon units Linux relies on (there is no managed
+ autostart). ``%h`` is expanded in the socket path so it can be probed; the exec target is left as written."""
home = os.path.expanduser("~")
+ # systemd --user and XDG autostart both honour $XDG_CONFIG_HOME; a host that sets it keeps its units there.
base = config_dir or os.environ.get("XDG_CONFIG_HOME") or os.path.join(home, ".config")
- findings: List[Tuple[str, str, str]] = []
+ units: List[Tuple[str, str, str, bool, Optional[str]]] = []
sources = (("systemd user unit", os.path.join(base, "systemd", "user"), ".service", "ExecStart"),
("XDG autostart entry", os.path.join(base, "autostart"), ".desktop", "Exec"))
for kind, directory, suffix, key in sources:
@@ -313,15 +312,50 @@ def _stale_cua_exec_references(config_dir: Optional[str] = None) -> List[Tuple[s
for line in text.splitlines():
stripped = line.strip()
tokens = stripped.split("=", 1)[1].split() if stripped.startswith(key + "=") else []
- if not tokens:
- continue
# first token = executable; systemd's prefix modifiers (-, +, !, :) never start a path
- target = tokens[0].lstrip("-+:!")
- resolved = os.path.expanduser(target.replace("%h", home))
- if "/packages/releases/" in resolved and not os.path.exists(resolved):
- findings.append((kind, name, target))
+ if not tokens or "cua-driver" not in tokens[0]:
+ continue
+ socket = next((tokens[i + 1] for i, t in enumerate(tokens[:-1]) if t == "--socket"), None)
+ units.append((kind, name, tokens[0].lstrip("-+:!"), "serve" in tokens[1:],
+ os.path.expanduser(socket.replace("%h", home)) if socket else None))
+ return units
+
+def _stale_cua_exec_references(config_dir: Optional[str] = None) -> List[Tuple[str, str, str]]:
+ """(kind, unit, target) for daemon units whose cua-driver Exec points at a pruned ``packages/releases/<version>/``
+ directory. The installer prunes all but the last five, so a versioned reference crash-loops with 203/EXEC after
+ every upgrade while every binary-level check stays green (#114748). ``packages/current`` and still-present
+ release dirs are healthy by construction and never reported."""
+ home = os.path.expanduser("~")
+ findings: List[Tuple[str, str, str]] = []
+ for kind, unit, target, _serve, _socket in cua_daemon_units(config_dir):
+ resolved = os.path.expanduser(target.replace("%h", home))
+ if "/packages/releases/" in resolved and not os.path.exists(resolved):
+ findings.append((kind, unit, target))
return findings
+def _apply_daemon_liveness_guard(report: Report, binary: str) -> Report:
+ """Append one check per configured daemon unit whose ``cua-driver serve`` is not answering on its socket
+ (pass when it is). Only configured daemons are probed: on Linux the MCP runtime needs no daemon, so an
+ unconfigured, silent socket is not a finding. Unknown probe results add nothing (#114748)."""
+ from tools.computer_use.cua_backend import cua_daemon_listening
+
+ checks = report.get("checks")
+ if sys.platform != "linux" or not isinstance(checks, list):
+ return report
+ for _kind, unit, _target, serve, socket in cua_daemon_units():
+ listening = cua_daemon_listening(binary, socket) if serve else None
+ if listening is None:
+ continue
+ shown = socket or "the default socket"
+ if listening:
+ checks.append({"name": f"daemon ({unit})", "status": "pass", "message": f"cua-driver serve is listening on {shown}"})
+ continue
+ checks.append({"name": f"daemon ({unit})", "status": "fail", "message": _DEAD_DAEMON_MSG.format(unit=unit, socket=shown),
+ "hint": _DEAD_DAEMON_HINT.format(unit=unit)})
+ if report.get("overall") == "ok":
+ report["overall"] = "degraded"
+ return report
+
def _apply_stale_unit_guard(report: Report) -> Report:
"""Append a fail check per hand-written unit/autostart entry whose cua-driver Exec target was pruned — the
daemon can crash-loop (203/EXEC) for days while every binary-level check stays green (#114748). Binary-level
@@ -408,6 +442,7 @@ def run_doctor(driver_cmd: Optional[str] = None, *, include: Sequence[str] = (),
return 2
report = _apply_display_count_guard(report)
report = _apply_stale_unit_guard(report)
+ report = _apply_daemon_liveness_guard(report, binary)
identity = _build_identity(binary, report)
environment = _wayland_environment_context(report)
if json_output:
diff --git a/website/docs/user-guide/features/computer-use.md b/website/docs/user-guide/features/computer-use.md
index 27efbea742c..dced6a9b6f2 100644
--- a/website/docs/user-guide/features/computer-use.md
+++ b/website/docs/user-guide/features/computer-use.md
@@ -204,6 +204,17 @@ The check matrix is platform-aware: `bundle_identity` / `tcc_*` are
`ax_capability` checks AX on macOS, UIA on Windows, AT-SPI on Linux —
each with the right diagnostic hint when it can't reach.
+On Linux, where the daemon is a hand-written systemd user unit or XDG
+autostart entry rather than a managed autostart, doctor also reads those
+units: a `cua-driver` `ExecStart` pointing at a pruned
+`packages/releases/<version>/` directory is reported as a failing
+`daemon unit (...)` check (point it at `~/.cua-driver/packages/current/cua-driver`),
+and a unit that runs `cua-driver serve` gets a `daemon (...)` check that
+connects to its socket — `fail` when nothing is listening (crash loop,
+stopped, never started), `pass` when the daemon answers. Reinstalling the
+driver does not start a daemon; `systemctl --user status <unit>` does.
+`hermes computer-use status` prints the same dead-daemon line and exits 1.
+
## The agent cursor and sessions
When the agent acts, you'll see a **tinted overlay cursor** glide